Electrostatic Deflector, one of the key components of SFC accelerator at IMP, is easily activated in the long-term running of HIRFL due to the bombardment with losing ions. The level of residual radioactivity induced in main components and dust contained in the electrostatic deflector enclosure have been investigated using gamma-ray spectrometry and Fluke 451p ionization chamber. The results indicate that the activated electrostatic deflector represent a significant radiological hazard for workers during maintenance operation, and the waste disposal difficulties should be encountered after decommissioning.

Keywords

Cite

@article{arxiv.1702.07639,
  title  = {Experimental Study of residual radioactivity induced in SFC Electrostatic Deflector},
  author = {Chong Xu and Wu-Yuan Li and Jun-Kui Xu and Yao Yang and Wang Mao and Wei-Wei Yan and You-Wu Su},
  journal= {arXiv preprint arXiv:1702.07639},
  year   = {2017}
}

Comments

The paper with the ID arXiv:1702.07639 had been returned by Chinese Physics C, so I want to withdraw the manuscript from arXiv