Abstract

We report about the performance of the HBU0 board and the optical calibration system QMB6 in the DESY test beam. A MIP signal was measured on the HBU0 board, providing a reference to the LED amplitude scan, showing an amount of light delivered to each of 12 SiPMs from 0 to 250 MIP at maximum. An ASIC analogue memory cell performance was analyzed in relation with the SiPM signal strength. We observed a non-uniformity and a pedestal shift in the ASIC readout values in the high gain mode for the higher signals strength.

Keywords

Cite

@article{arxiv.1105.4745,
  title  = {Beam test of the QMB6 calibration board and HBU0 prototype},
  author = {Jaroslav Cvach and Jiri Kvasnicka and Ivo Polak and Jaroslav Zalesak},
  journal= {arXiv preprint arXiv:1105.4745},
  year   = {2011}
}

Comments

12 pages, 16 figures, EUDET project memo