English

Multiaxis atom interferometry with a single diode laser and a pyramidal magneto-optical trap

Atomic Physics 2018-02-13 v4 Instrumentation and Detectors Optics

Abstract

Atom interferometry has become one of the most powerful technologies for precision measurements. To develop simple, precise, and versatile atom interferometers for inertial sensing, we demonstrate an atom interferometer measuring acceleration, rotation, and inclination by pointing Raman beams toward individual faces of a pyramidal mirror. Only a single diode laser is used for all functions, including atom trapping, interferometry, and detection. Efficient Doppler-sensitive Raman transitions are achieved without the velocity selecting the atom sample, and with zero differential AC Stark shift between the cesium hyperfine ground states, increasing signal-to-noise and suppressing systematic effects. We measure gravity along two axes (vertical and 45^\circ to the vertical), rotation, and inclination with sensitivities of 6μ\,\mum/s2/Hz^2/\sqrt{\rm Hz}, 300μ\,\murad/s/Hz\sqrt{\rm Hz}, and 4μ\,\murad/Hz\sqrt{\rm Hz}, respectively. This work paves the way toward deployable multiaxis atom interferometers for geodesy, geology, or inertial navigation.

Keywords

Cite

@article{arxiv.1707.08693,
  title  = {Multiaxis atom interferometry with a single diode laser and a pyramidal magneto-optical trap},
  author = {Xuejian Wu and Fei Zi and Jordan Dudley and Ryan J. Bilotta and Philip Canoza and Holger Müller},
  journal= {arXiv preprint arXiv:1707.08693},
  year   = {2018}
}

Comments

7 pages, 7 figures

R2 v1 2026-06-22T20:58:44.065Z