English

Minimum Component Based First-Order Inverting and Non-inverting Outputs of All-Pass Filter at the Same Circuit

Other Computer Science 2012-10-10 v1

Abstract

In this paper, a new voltage-mode first order all-pass filter using minimum active and passive components is presented. The proposed circuit employs one fully differential second generation current conveyor (FDCCII), one grounded capacitor, one resistor and offers the following advantages: the use of only grounded capacitor which is attractive for integrated circuit implementation, low active and passive sensitivities, providing inverting and non-inverting voltage-mode all-pass responses simultaneously from the single circuit and no requirement for component matching conditions. The theory is validated through PSPICE simulation using TSMC 0.35micrometer CMOS process parameters.

Keywords

Cite

@article{arxiv.1210.2485,
  title  = {Minimum Component Based First-Order Inverting and Non-inverting Outputs of All-Pass Filter at the Same Circuit},
  author = {J. Mohan and S. Maheshwari and D. S. Chauhan},
  journal= {arXiv preprint arXiv:1210.2485},
  year   = {2012}
}

Comments

ACEEE International Journal on Electrical and Power Engineering, 2010

R2 v1 2026-06-21T22:18:28.621Z