English

Magnetic Induction Imaging with a cold-atom radio-frequency magnetometer

Atomic Physics 2020-10-12 v1 Applied Physics Instrumentation and Detectors

Abstract

The sensitive detection of either static or radio-frequency \textsc{(rf)} magnetic fields is essential to many fundamental studies and applications. Here, we demonstrate the operation of a cold-atom-based, \textsc{rf} magnetometer in performing {1-D and 2-D imaging} of small metallic objects. It is based on a cold 85^{85}Rb atomic sample, and operates in an unshielded environment with no active field stabilization. It shows a sensitivity up to 200pT/Hz200\, \rm{pT}/\sqrt{\rm Hz} in the 535kHz5-35\, \rm{kHz} range bandwidth and can resolve a cut 0.4mm0.4\, \rm{mm} wide in a 0.8mm0.8\, \rm{mm} thick metallic foil. The characteristics of our system make it a good candidate for applications in civil and industrial surveillance.

Keywords

Cite

@article{arxiv.2010.04437,
  title  = {Magnetic Induction Imaging with a cold-atom radio-frequency magnetometer},
  author = {Alessandro Fregosi and Carlo Gabbanini and Silvia Gozzini and Lorenzo Lenci and Carmela Marinelli and Andrea Fioretti},
  journal= {arXiv preprint arXiv:2010.04437},
  year   = {2020}
}

Comments

5 pages, 5 figures

R2 v1 2026-06-23T19:12:04.600Z