English

Deep learning-based attenuation correction in the image domain for myocardial perfusion SPECT imaging

Medical Physics 2021-02-11 v2 Image and Video Processing

Abstract

Objective: In this work, we set out to investigate the accuracy of direct attenuation correction (AC) in the image domain for the myocardial perfusion SPECT imaging (MPI-SPECT) using two residual (ResNet) and UNet deep convolutional neural networks. Methods: The MPI-SPECT 99mTc-sestamibi images of 99 participants were retrospectively examined. UNet and ResNet networks were trained using SPECT non-attenuation corrected images as input and CT-based attenuation corrected SPECT images (CT-AC) as reference. The Chang AC approach, considering a uniform attenuation coefficient within the body contour, was also implemented. Quantitative and clinical evaluation of the proposed methods were performed considering SPECT CT-AC images of 19 subjects as reference using the mean absolute error (MAE), structural similarity index (SSIM) metrics, as well as relevant clinical indices such as perfusion deficit (TPD). Results: Overall, the deep learning solution exhibited good agreement with the CT-based AC, noticeably outperforming the Chang method. The ResNet and UNet models resulted in the ME (count) of 6.99±16.72{-6.99\pm16.72} and 4.41±11.8{-4.41\pm11.8} and SSIM of 0.99±0.04{0.99\pm0.04} and 0.98±0.05{0.98\pm0.05}, respectively. While the Change approach led to ME and SSIM of 25.52±33.98{25.52\pm33.98} and 0.93±0.09{0.93\pm0.09}, respectively. Similarly, the clinical evaluation revealed a mean TPD of 12.78±9.22{12.78\pm9.22} and 12.57±8.93{12.57\pm8.93} for the ResNet and UNet models, respectively, compared to 12.84±8.63{12.84\pm8.63} obtained from the reference SPECT CT-AC images. On the other hand, the Chang approach led to a mean TPD of 16.68±11.24{16.68\pm11.24}. Conclusion: We evaluated two deep convolutional neural networks to estimate SPECT-AC images directly from the non-attenuation corrected images. The deep learning solutions exhibited the promising potential to generate reliable attenuation corrected SPECT images without the use of transmission scanning.

Keywords

Cite

@article{arxiv.2102.04915,
  title  = {Deep learning-based attenuation correction in the image domain for myocardial perfusion SPECT imaging},
  author = {Samaneh Mostafapour and Faeze Gholamiankhah and Sirvan Maroofpour and Mahdi Momennezhad and Mohsen Asadinezhad and Seyed Rasoul Zakavi and Hossein Arabi},
  journal= {arXiv preprint arXiv:2102.04915},
  year   = {2021}
}
R2 v1 2026-06-23T22:59:10.076Z