English

Cryogenic readout for multiple VUV4 Multi-Pixel Photon Counters in liquid xenon

Instrumentation and Detectors 2018-04-18 v5 High Energy Physics - Experiment

Abstract

We present the performances and characterization of an array made of S13370-3050CN (VUV4 generation) Multi-Pixel Photon Counters manufactured by Hamamatsu and equipped with a low power consumption preamplifier operating at liquid xenon temperature (~ 175 K). The electronics is designed for the readout of a matrix of maximum dimension of 8 x 8 individual photosensors and it is based on a single operational amplifier. The detector prototype presented in this paper utilizes the Analog Devices AD8011 current feedback operational amplifier, but other models can be used depending on the application. A biasing correction circuit has been implemented for the gain equalization of photosensors operating at different voltages. The results show single photon detection capability making this device a promising choice for future generation of large scale dark matter detectors based on liquid xenon, such as DARWIN.

Keywords

Cite

@article{arxiv.1707.08004,
  title  = {Cryogenic readout for multiple VUV4 Multi-Pixel Photon Counters in liquid xenon},
  author = {F. Arneodo and M. L. Benabderrahmane and G. Bruno and V. Conicella and A. Di Giovanni and O. Fawwaz and M. Messina and A. Candela and G. Franchi},
  journal= {arXiv preprint arXiv:1707.08004},
  year   = {2018}
}

Comments

19 pages, 14 figures

R2 v1 2026-06-22T20:56:54.581Z