Beam-based detector alignment in the MICE muon beam line
Instrumentation and Detectors
2018-05-18 v1 High Energy Physics - Experiment
Abstract
The Muon Ionization Cooling Experiment (MICE) will perform a detailed study of ionization cooling to evaluate the feasibility of the technique. To carry out this program, MICE requires all of its detectors to reconstruct space points in a globally consistent fashion. The beam-based alignment constants were found to be more accurate than the survey for the scintillating-fibre trackers lodged inside the bores of the superconducting magnets. This alignment algorithm can achieve unbiased measurements of the trackers rotation angles with a resolution of 6 mrad/ and of their position with a resolution of 20 mm/, with the number of selected tracks.
Keywords
Cite
@article{arxiv.1805.06623,
title = {Beam-based detector alignment in the MICE muon beam line},
author = {F. Drielsma},
journal= {arXiv preprint arXiv:1805.06623},
year = {2018}
}