Related papers: Phase Sensitivity of a Mach-Zehnder Interferometer
Interferometry with NOON quantum states can provide unbiased phase estimation with a sensitivity scaling as $\Delta \theta \sim 1/N_T$ given a prior knowledge that the true phase shift $\theta$ lies in the interval $-\pi \leq \theta \leq…
We have studied the zero-temperature statistics of charge transfer between the two edges of Quantum Hall liquids with filling factors $\nu_{0,1}=1/(2 m_{0,1}+1)$ forming Mach-Zehnder interferometer. The known Bethe ansatz solution for…
We study sensitivity of phase estimation of Mach-Zehnder (MZ) interferometer with original two-mode squeezed vacuum (TMSV) state. At the initial stage, the TMSV state is converted into two single-mode squeezed vacuum (SMSV) states, from…
We optimize two-mode, entangled, number states of light in the presence of loss in order to maximize the extraction of the available phase information in an interferometer. Our approach optimizes over the entire available input Hilbert…
We demonstrate a 2-grating free electron Mach-Zehnder interferometer constructed in a transmission electron microscope. A symmetric binary phase grating and condenser lens system forms two spatially separated, focused probes at the sample…
We demonstrate that important information about linear optical circuits can be obtained through the phase shift induced by integrated optical resonators. As a proof of principle, the phase of an unbalanced Mach-Zehnder interferometer is…
The SU(1,1) interferometer can be thought of as a Mach-Zehnder interferometer with its linear beamsplitters replaced with parametric nonlinear optical processes. We consider the cases of bright and vacuum-seeded SU(1,1) interferometers…
We have previously shown that quantum-enhanced atom interferometry can be achieved by mapping the quantum state of squeezed optical vacuum to one of the atomic inputs via a beamsplitter-like process [Phys.~Rev.~A \textbf{90}, 063630…
We study fermions in a Mach-Zehnder interferometer, subject to a quantum-mechanical environment leading to inelastic scattering, decoherence, renormalization effects, and time-dependent conductance fluctuations. Both the loss of…
In interferometry, sub-Heisenberg strategies claim to achieve a phase estimation error smaller than the inverse of the mean number of photons employed (Heisenberg bound). Here we show that one can achieve a comparable precision without…
Photonic information processing demands programmable multiport interferometers capable of implementing arbitrary transfer matrices, for which planar meshes of error-sensitive Mach-Zehnder interferometers are usually exploited. We propose an…
We propose a new single-step scheme for the generation of a GHZ entangled state of three single-electron excitations (flying qubits). We also present a method to get a generalized GHZ-state. Our idea relies upon the most recent progress in…
The measurement of physical parameters is one of the main pillars of science. A classic example is the measurement of the optical phase enabled by optical interferometry where the best sensitivity achievable with N photons scales as 1/N -…
Quantum Cramer-Rao (QCR) bound is attached to a particular nonclassical state, therefore appropriate choice of the probe state is of the key importance to enhance sensitivity beyond classical one. Since the work of C.M. Caves (Phys. Rev. D…
We propose an $N$-photon Gaussian measurement scheme which allows the estimation of a parameter $\varphi$ encoded into a multi-port interferometer with a Heisenberg scaling precision (i.e. of order $1/N$). In this protocol, no restrictions…
Perfect-crystal neutron interferometry which is analogous to Mach-Zehnder interferometry, uses Bragg diffraction to form interfering neutron paths. The measured phase shifts can be used to probe many types of interactions whether it be…
Recently, the Hilbert-Schmidt speed, as a special class of quantum statistical speed, has been reported to improve the interferometric phase in single-parameter quantum estimation. Here, we test this concept in the multiparameter scenario…
We theoretically study the phase sensitivity of the SU(1,1) interferometer with a coherent light together with a squeezed vacuum input case using the method of homodyne. We find that the homodyne detection has better sensitivity than the…
We propose a dynamical scheme for measuring the full counting statistics in a mesoscopic conductor using an electronic Mach-Zehnder interferometer. The conductor couples capacitively to one arm of the interferometer and causes a phase shift…
A high-sensitive interferometric scheme is presented. It is based on homodyne detection and squeezed vacuum phase properties. The resulting phase sensitivity scales as $\delta\phi \simeq {1/4} \bar{n}^{-1}$ with respect to input photons…