Related papers: New intensity and visibility aspects of a double l…
A simple, low-cost millimeter-wave (70 GHz) interferometer with a phase accuracy better than plus or minur 2 degrees, and a response time of 10 ns is described. The simplicity of this interferometer makes it ideal for measurement of…
The use of an ultracold neutron interferometer incorporating an electrostatic accelerator having a strong electric field gradient to accelerate neutrons by their possible electric moments is proposed as a method of measuring the neutron…
We report on an Edge Illumination setup enabling neutron dark-field imaging where two amplitude modulators are used to structure and subsequently analyze the neutron beam. The modulator and analyzer are manufactured by laser ablation of…
Diffraction of slow neutrons by nanoparticle-polymer composite gratings has been observed. By carefully choosing grating parameters such as grating thickness and spacing, a three-port beam splitter operation for cold neutrons - splitting…
We consider Mach-Zehnder and Hong-Ou-Mandel interferometers with nonclassical states of light as input, and study the effect that dispersion inside the interferometer has on the sensitivity of phase measurements. We study in detail a number…
A new type of an optical interferometer is discussed the phase difference between the interfering beams in which is substantially wavelength dependent. It is shown that the function measured with this device is an integral transform of the…
We calculate the utility of high-frequency squeezed-state enhanced two-frequency interferometry for low-frequency phase measurement. To use the high-frequency sidebands of the squeezed light, a two-frequency intense laser is used in the…
The phase uncertainty of an unseeded nonlinear interferometer, where the output of one nonlinear crystal is transmitted to the input of a second crystal that analyzes it, is commonly said to be below the shot-noise level but highly…
We study the phase sensitivity of SU(2) and SU(1,1) interferometers fed by two-mode field states which are intelligent states for Hermitian generators of the SU(2) and SU(1,1) groups, respectively. Intelligent states minimize uncertainty…
Combining high and low probability densities in intensity hybrids, we study some of their properties in double-slit setups. In particular, we connect to earlier results on beam attenuation techniques in neutron interferometry and study the…
The best performance of a Mach-Zehnder interferometer is achieved with the input state |N_T/2 + 1>|N_T/2-1 > + |N_T/2 - 1>|N_T/2+1>, being N_T the total number of atoms/photons. This gives: i) a phase-shift error confidence C_{68%}=2.67/N_T…
We study a nonlinear interferometer consisting of two consecutive parametric amplifiers, where all three optical fields (pump, signal and idler) are treated quantum mechanically, allowing for pump depletion and other quantum phenomena. The…
The Mach--Zehnder interferometer is a powerful device for detecting small phase shifts between two light beams. Simple input states -- such as coherent states or single photons -- can reach the standard quantum limit of phase estimation…
Stellar intensity interferometers correlate photons within their coherence time and could overcome the baseline limitations of existing amplitude interferometers. Intensity interferometers do not rely on phase coherence of the optical…
Interferometry is an indispensable tool across all the natural sciences. Recently, a new type of interferometer based on phase-sensitive Fano resonances has been proposed and implemented. In these Fano interferometers, the two arms are…
A new technique for maintaining high contrast in an atom interferometer is used to measure large de Broglie wave phase shifts. Dependence of an interaction induced phase on the atoms' velocity is compensated by applying an engineered…
Quantum interferometry uses quantum resources to improve phase estimation with respect to classical methods. Here we propose and theoretically investigate a new quantum interferometric scheme based on three-dimensional waveguide devices.…
The use of Raman laser generated by modulation for light-pulse atom interferometer allows to have a laser system more compact and robust. However, the additional laser frequencies generated can perturb the atom interferometer. In this…
We derive generic phase and amplitude coupling relations for beam splitters-combiners that couple a single port with three output ports or input ports, respectively. We apply the coupling relations to a reflection grating that serves as a…
We describe a light-pulse atom interferometer that is suitable for any species of atom and even for electrons and protons as well as their antiparticles, in particular for testing the Einstein equivalence principle with antihydrogen. The…