Related papers: Approaching the Heisenberg limit with two mode squ…
The ultimate precision of phase estimation is limited by the Heisenberg scaling $\Delta\phi_0 = K/N$, where $K\sim1$ is a numerical prefactor and $N$ is the mean number of photons interacting with the phase shifting object(s). However,…
The canonical Mach-Zehnder interferometer fed with a coherent state and a squeezed-vacuum state of equal intensities is theoretically predicted to achieve Heisenberg scaling in phase sensitivity. However, this ultimate performance is…
The phase resolution of interferometers is limited by the so-called Heisenberg limit, which states that the optimum phase sensitivity is inversely proportional to the number of interfering particles N, a 1/sqrt{N} improvement over the…
We provide general bounds of phase estimation sensitivity in linear two-mode interferometers. We consider probe states with a fluctuating total number of particles. With incoherent mixtures of state with different total number of particles,…
Achieving the ultimate quantum precision in the estimation of multiple physical parameters simultaneously is a challenge in quantum metrology due to fundamental limitations and experimental challenges in harnessing the necessary quantum…
The precision of phase estimation with interferometers can be greatly enhanced using non-classical quantum states, and the SU(11) interferometer is an elegant scheme, which generates two-mode squeezed state internally and also amplifies the…
The Mach--Zehnder interferometer is a powerful device for detecting small phase shifts between two light beams. Simple input states -- such as coherent states or single photons -- can reach the standard quantum limit of phase estimation…
We investigate the scaling of the phase sensitivity of a nonideal Heisenberg-limited interferometer with the particle number N, in the case of the Bayesian detection procedure proposed by Holland and Burnett [p.r.l. 71, p. 1355 (1993)] for…
A Mach-Zender interferometer with a gaussian number-difference squeezed input state can exhibit sub-shot-noise phase resolution over a large phase-interval. We obtain the optimal level of squeezing for a given phase-interval…
We propose an approach to quantum phase estimation that can attain precision near the Heisenberg limit without requiring single-particle-resolved state detection. We show that the "one-axis twisting" interaction, well known for generating…
We show that the phase sensitivity $\Delta \theta$ of a Mach-Zehnder interferometer fed by a coherent state in one input port and squeezed-vacuum in the other one is i) independent from the true value of the phase shift and ii) can reach…
Building robust instruments capable of making interferometric measurements with precision beyond the standard quantum limit remains an important goal in many metrology laboratories. We describe here the basic concepts underlying spin…
We derive, and experimentally demonstrate, an interferometric scheme for unambiguous phase estimation with precision scaling at the Heisenberg limit that does not require adaptive measurements. That is, with no prior knowledge of the phase,…
After reviewing parity measurement based interferometry with twin-Fock states, which allows for super-sensitivity (Heisenberg-limited) and super-resolution, we consider interferometry with two different superpositions of twin-Fock states,…
Fundamental phase-shift detection properties of optical multimode interferometers are analyzed. Limits on perfectly distinguishable phase shifts are derived for general quantum states of a given average energy. In contrast to earlier work,…
A two-step detection strategy is suggested for the precise measurement of the optical phase-shift. In the first step an unsharp, however, unbiased joint measurement of the phase and photon number is performed by heterodyning the signal…
By considering matter wave bright solitons from weakly coupled Bose-Einstein condensates trapped in a double-well potential, we study the formation of macroscopic non-classical states, including Schr\"odinger-cat superposition states and…
Phase measurement using a lossless Mach-Zehnder interferometer with certain entangled $N$-photon states can lead to a phase sensitivity of the order of 1/N, the Heisenberg limit. However, previously considered output measurement schemes are…
Two-mode interferometers, such as Michelson interferometer based on two spatial optical modes, lay the foundations for quantum metrology. Instead of exploring quantum entanglement in the two-mode interferometers, a single bosonic mode also…
When measuring a time-varying phase, the standard quantum limit and Heisenberg limit as usually defined, for a constant phase, do not apply. If the phase has Gaussian statistics and a power-law spectrum $1/|\omega|^p$ with $p>1$, then the…