English
Related papers

Related papers: Quality control of GEM detectors using scintillati…

200 papers

The nature of stacking faults - whether intrinsic or extrinsic - plays a pivotal role in defect-mediated processes in crystalline materials. Yet, current electron microscopy techniques for their reliable analysis remain limited to either…

We describe a concept for a NASA SMEX Mission in which Gas Electron Multiplier (GEM) detectors, developed at CERN, are adapted for use in X-ray astronomy. These detectors can be used to obtain moderately large detector area and…

A wire GEM (WGEM) detector with a gas gap between meshes was constructed. The detector provides the amplification 5x10E5 for the gas mixture of Ar +20% CO2 at atmospheric pressure. As compared with well-known GEM detectors produced by…

Instrumentation and Detectors · Physics 2009-11-26 B. M. Ovchinnikov , V. I. Razin , A. I. Reshetin , S. N. Filippov

A new gas detector prototype for the upgrade of the focal plane detector of the MAGNEX large-acceptance magnetic spectrometer has been developed and tested in view of the NUMEN project. It has been designed to operate at low gas pressure…

In this contribution we describe a novel solution for the construction of Positron Emission Tomograph. We present the device allowing for determination of the impact position as well as time and deph of interaction of the annihilation gamma…

Medical Physics · Physics 2013-10-15 P. Moskal , P. Salabura , M. Silarski , J. Smyrski , J. Zdebik , M. Zieliński

The CSC (cryogenic scintillating calorimeter) technology devoted to rare event searches is reaching the sensitivity level required for the hunt of dark matter-electron scatterings. Dark matter-electron interactions in scintillating targets…

High Energy Physics - Phenomenology · Physics 2025-07-18 V. Zema , P. Figueroa , G. Angloher , M. R. Bharadwaj , T. Frank , M. N. Hughes , M. Kellermann , F. Pröbst , K. Schäffner , K. Shera , M. Stahlberg

Precision timing has played a critical role in high-energy physics experiments, particularly for particle identification and the suppression of pileup under the challenging conditions expected at future colliders like the High-Luminosity…

Instrumentation and Detectors · Physics 2026-03-31 Martina Malberti , Xiaohu Sun

We present results from our recent investigations on detectors comprising cascaded gas electron multipliers (GEM) and cascaded GEMs with micro-hole and strip (MHSP) electrodes. We discuss the factors governing the operation of these fast…

Scintillating homogeneous detectors represent the state of the art in electromagnetic calorimetry. Moreover, the currently neglected crystalline nature of the most common inorganic scintillators can be exploited to achieve an outstanding…

Samples from different materials typically used as optical windows or light guides in scintillation detectors were studied in a very low background environment, at the Canfranc Underground Laboratory, searching for scintillation. A positive…

A new concept for a hybrid structure gaseous detector module with ion backflow suppression for the time projection chamber in a future circular collider is presented. It is a hybrid structure cascaded Gas Electron Multiplier (GEM) with a…

Instrumentation and Detectors · Physics 2017-04-03 YuLian Zhang , HuiRong Qi , BiTao Hu , Hai-Yun Wang , Qun Ou-Yang , Yuan-Bo Chan , Jian Zhang , Zhi-Wen Wen

Noble gas radiation detectors with optical readout are gaining popularity in fields like astrophysics and particle physics due to their ability to produce both ionization and scintillation signals in response to ionizing radiation…

Instrumentation and Detectors · Physics 2024-10-31 J. M. R. Teixeira , C. A. O. Henriques , P. A. O. C. Silva , R. D. P. Mano , J. M. F. Dos Santos , C. M. B. Monteiro

In gamma ray imaging, a scintillation crystal is typically used to convert the gamma radiation into visible light. Photosensors are used to transform this light into measurable signals. Several types of photosensors are currently in use…

Gas electron multiplier(GEM) detector is used in Cosmic Muon Scattering Tomography and neutron imaging in the last decade. In this work, a triple GEM device with an effective readout area of 10 cm X 10 cm is developed, and an experiment of…

Instrumentation and Detectors · Physics 2016-05-04 Wu Hui-Yin , Zhao Sheng-Ying , Wang Xiao-Dong , Zhang Xian-Ming , Qi Hui-Rong , Zhang Wei , Wu Ke-Yan , Hu Bi-Tao , Zhang Yi

Observations of X-ray cavities formed by powerful jets from AGN in galaxy cluster cores are commonly used to estimate the mechanical luminosity of these sources. We test the reliability of observationally measuring this power with synthetic…

High Energy Astrophysical Phenomena · Physics 2015-05-14 Peter J. Mendygral , Sean M. O'Neill , Tom W. Jones

Scintillation detector has lower energy resolution for Gamma-ray as compared to semiconductor detector, better spectra analysis method is essential to traditional method. A model for describing the response function of scintillation…

Instrumentation and Detectors · Physics 2014-07-04 Zhe Li , Yiwen Zhang , Shifeng Sun , Baoyi Wang , Long Wei

We investigate the influence of the high voltage scheme elements on the stability of a detector based on a single $10\times10$ cm$^2$ area GEM with respect to the secondary discharge occurrence. These violent events pose a major threat to…

Instrumentation and Detectors · Physics 2019-10-09 L. Lautner , L. Fabbietti , P. Gasik , T. Klemenz

Scintillators are transparent materials that interact with high-energy particles and emit visible light as a result. They are used in state of the art methods of measuring high-energy particles and radiation sources. Most existing methods…

Instrumentation and Detectors · Physics 2026-03-17 Alex Bocchieri , John Mamish , David Appleyard , Andreas Velten

Current radiation portal monitors at sea ports and international borders that employ standard radiation detection techniques are not very sensitive to nuclear contraband that is well shielded to absorb emanating radiation. Muon Tomography…

Instrumentation and Detectors · Physics 2016-11-17 M. Hohlmann , K. Gnanvo , L. Grasso , J. B. Locke , A. Quintero , D. Mitra

Proportional scintillation counters (PSCs), both single- and dual-phase, can measure the scintillation (S1) and ionization (S2) channels from particle interactions within the detector volume. The signal obtained from these detectors depends…

Instrumentation and Detectors · Physics 2016-03-23 Kareem Kazkaz , Tenzing Henry Yatish Joshi