Related papers: The Micro Slit Gas Detector
In this work we describe a parallel geometry gaseous detector constituted by a thin (0.6 mm) amplifying gap preceded by a drift region. The gap is delimited by a metal plate and by a wire mesh. The detector can count up to a rate of 10^7…
The Spherical gaseous detector (or Spherical Proportional Counter, SPC) has a broad range of applications. In this work, we will focus on the light WIMP Dark Matter particle search, that is, below a few GeV. The NEWS-G collaboration…
We report a self-aligned, monolithic electron interferometer, consisting of two 45 nm thick silicon layers separated by 20 $\mu$m. This interferometer was fabricated from a single crystal silicon cantilever on a transmission electron…
New Micromegas (Micro-mesh gaseous detectors) are being developed in view of the future physics projects planned by the COMPASS collaboration at CERN. Several major upgrades compared to present detectors are being studied: detectors…
In recent years important progress in micropattern gaseous detectors has been achieved in the use of resistive material to build compact spark-protected devices. The novel idea presented here consists of the polarisation of WELL structures…
We measured the electronic properties and gas sensing response of nanowires containing segments of poly(3,4-ethylenedioxythiophene)/poly(styrenesulfonate) (PEDOT/PSS) that were synthesized using anodic aluminum oxide (AAO) membranes. The…
We present results from a detailed GEANT4 simulation of a proposed Muon Tomography System that employs compact Micro Pattern Gas Detectors with high spatial resolution. A basic Point-Of-Closest-Approach algorithm is applied to reconstructed…
We have constructed and tested a 2d position sensitive parallel-plate gas ionization chamber with scanned charge transfer readout. The scan readout method described here is based on the development of a new position dependent charge…
The fabrication and experimental characterization of a thermal flow meter, capable of detecting and measuring two independent gas flows with a single chip, is described. The device is based on a 4 x 4 mm2 silicon chip, where a series of…
This paper presents a new shield configuration for cryogenic current comparators (CCCs), namely the folded coaxial geometry. An analytical model describing its shielding performance is first developed, and then validated by means of finite…
We describe a work of a multi-cathode counter of the developed design in a single electron counting mode with a cathode made of aluminum alloy. The results of the calibration of the counter are presented. The coefficient of gas…
The fast timing MPGD is a micro-pattern gaseous detector conceived for achieving sub-nanosecond time resolution while maintaining the ability to instrument large areas in high-rate environments; applications of such technology are…
The sensitivity of a gold-silver bilayer system for gas detection was investigated using angle-fixed reflectance measurements and numerical calculations based on the transfer-matrix method. Two configurations of bilayer systems were…
This paper presents a readout system designed for testing the prototype of Small-Strip Thin Gap Chamber (sTGC), which is one of the main detector technologies used for ATLAS New-Small-Wheel Upgrade. This readout system aims at testing one…
An X-ray detector will be presented that is the combination of a segmented ionization chamber featuring one-dimensional spatial resolution integrated with an intelligent ADC front-end, multi DSP processing and embedded PC platform. This…
The GanESS experiment will exploit the high-pressure noble gas time projection chamber technology to detect coherent elastic neutrino-nucleus scattering (CE$\nu$NS) at the European Spallation Source (ESS). The detector, able to operate at…
A new gas detector prototype for the upgrade of the focal plane detector of the MAGNEX large-acceptance magnetic spectrometer has been developed and tested in view of the NUMEN project. It has been designed to operate at low gas pressure…
A prototype of a single-gap glass Resistive Plate Chamber (RPC) is constructed by the authors. To find the considerations required for better operation of the detector's gas system, we have simulated the flow of the Ar gas through the…
Gas electron multipliers (GEMs) with wire (WGEMs) or metal electrodes (MGEMs), which don't use any plastic insulators between the electrodes are created. The absence of plastic insulation between the electrodes of WGEMs excludes unwanted…
The construction of a butt-end multicell matrix proportional counter (MMPC) is presented in the work. Each cell is a butt-end proportional counter with a 5 mm cathode diameter and 0.8 mm circular anode diameter. In the example of the…