English
Related papers

Related papers: MSGC Development for HERA-B

200 papers

To extend the acceptance of the CMS muon spectrometer to the region 2.4 $<|\eta|<$ 2.8, stacks of triple-GEM chambers, forming the ME0 station, are planned for the CMS Phase 2 Upgrade. These large-area micro-pattern gaseous detectors must…

We describe a concept for a NASA SMEX Mission in which Gas Electron Multiplier (GEM) detectors, developed at CERN, are adapted for use in X-ray astronomy. These detectors can be used to obtain moderately large detector area and…

In this work, we have tried to develop a detailed understanding of the physical processes occurring in those variants of Micro Pattern Gas Detectors (MPGDs) that share micro hole and micro strip geometry, like GEM, MHSP and MSGC etc. Some…

Instrumentation and Detectors · Physics 2016-05-11 Purba Bhattacharya , Supratik Mukhopadhyay , Nayana Majumdar , Sudeb Bhattacharya

The extension of data acquisition for the BEijing Spectrometer (BESIII) experiment until at least 2030 has resulted in upgrades to both the accelerator and the detector. An innovative Cylindrical Gas Electron Multiplier (CGEM) is under…

Instrumentation and Detectors · Physics 2022-12-22 Alberto Bortone

In the DeeMe experiment, approximately $70\ \mathrm{GHz/mm^{2}}$ prompt-charged particles will hit the multi-wire proportional chambers (MWPCs) before signal electrons come. To avoid the space charge effect, we developed fast HV-switching…

Instrumentation and Detectors · Physics 2018-12-05 N. Teshima

Gas Electron Multiplier (GEM) detectors, typically featuring a standard pitch size of 140 $\mu$m and an inner hole diameter of 50 $\mu$m, are extensively utilized in high-energy physics experiments for tracking, triggering, and timing…

High Energy Physics - Experiment · Physics 2025-05-07 Rajiv Gupta , Gauri Devi , Sunidhi Saxena , Arpit Singh , Ajay Kumar

The long-term stability in terms of gain and energy resolution of a prototype triple Gas Electron Multiplier (GEM) detector has been investigated with high rate X-ray irradiation. Premixed Ar/CO2 (80:20) and (90:10) gases have been used for…

Instrumentation and Detectors · Physics 2021-07-05 S Chatterjee , S Roy , A Sen , S Chakraborty , S Das , S K Ghosh , S K Prasad , S Raha , S Biswas

Gas Electron Multiplication technology is finding more and more applications in beam instrumentation and at CERN these detectors have recently been adapted for use in transverse profile measurements at several of our facilities. In the…

Instrumentation and Detectors · Physics 2013-09-12 Serge Duarte Pinto , Jens Spanggaard

The present work involves the comparison of various bulk Micromegas detectors having different design parameters. Six detectors with amplification gaps of $64,~128,~192,~220 ~\mu\mathrm{m}$ and mesh hole pitch of $63,~78 ~\mu\mathrm{m}$…

Instrumentation and Detectors · Physics 2016-05-12 Purba Bhattacharya , Sudeb Bhattacharya , Nayana Majumdar , Supratik Mukhopadhyay , Sandip Sarkar , Paul Colas , David Attie

Gaseous detectors are used in high energy physics as trackers or, more generally, as devices for the measurement of the particle position. For this reason, they must provide high spatial resolution and they have to be able to operate in…

A cylindrical GEM tracker is under construction in order to replace and improve the inner tracking system of the BESIII experiment. Tests with planar chamber prototypes were carried out on the H4 beam line of SPS (CERN) with muons of 150…

We report on the systematic study of a single-gas-electron-multiplication (GEM) loaded gaseous detector developed for precision measurements of high-energy particle beams and dose-verification measurements. In the present study, a…

Instrumentation and Detectors · Physics 2014-07-29 Kyong Sei Lee , Byungsik Hong , Sang Yeol Kim , Sung Keun Park

A prototype Gas Electron Multiplier (GEM) detector is under construction for medical imaging purposes. A single thick GEM of size 10x10 cm^2 is assembled inside a square shaped air-tight box which is made of Perspex glass. In order to…

Instrumentation and Detectors · Physics 2013-07-05 N. N. Mondal , S. Chattopadhyay , M. R. Dutta Mazumdar , A. K. Dubey , Y. P. Vioygi

The Gas Electron Multiplier (GEM) has become a widely used technology for high-rate particle physics experiments like COMPASS, LHCb and are being used as the readout system for the upcoming upgrade version of other experiments such as ALICE…

Instrumentation and Detectors · Physics 2021-05-26 Promita Roy , Purba Bhattacharya , Supratik Mukhopadhyay , Nayana Majumdar

Gas detector are very light instrument used in high energy physics to measure the particle properties: position and momentum. Through high electric field is possible to use the Gas Electron Multiplier (GEM) technology to detect the charged…

Calorimetry at future linear colliders could be based on a particle flow approach where granularity is the key to high jet energy resolution. Among different technologies, Micromegas chambers with 1 cm2 pad segmentation are studied for the…

A prototype of a single-gap glass Resistive Plate Chamber (RPC) is constructed by the authors. To find the considerations required for better operation of the detector's gas system, we have simulated the flow of the Ar gas through the…

Instrumentation and Detectors · Physics 2021-11-30 Yousef Pezeshkian , Amir Kiyoumarsioskouei , Majid Ahmadpouri , Ghasem Ghorbani

The requirement of a large number of electronic channels poses a big challenge for Micro-pattern Gas Detector (MPGD) to achieve good spatial resolution. By using the redundancy that at least two neighboring strips record the signal of a…

Instrumentation and Detectors · Physics 2016-08-03 Bin-Xiang Qi , Shu-Bin Liu , Heng Ji , Zhong-Tao Shen , Si-Yuan Ma , Hong-Bang Liu , Wen-Qian Huang , Qi An

(Abridged version) The CMS experiment at the LHC will begin operation in 2007. The CMS Tracker sub-detector, comprises ~10 million detector channels read out by ~40 000 analog optical links. The optoelectronic components have been designed…

Instrumentation and Detectors · Physics 2010-05-03 Stefanos Dris

The tracking system of the dielectron spectrometer HADES at GSI Darmstadt is formed out of 24 low-mass, trapezoidal multi-layer drift chambers providing in total about 30 square meter of active area. Low multiple scattering in the in total…

Instrumentation and Detectors · Physics 2019-08-14 C. Muentz