English
Related papers

Related papers: The ring imaging Cherenkov detector for the BRAHMS…

200 papers

Using air showers induced by TeV gamma-rays from Mrk 501, the radial distribution of Cherenkov light is investigated. The shower geometry is reconstructed from the stereoscopic shower images obtained with the telescopes of the HEGRA IACT…

Astrophysics · Physics 2011-05-23 HEGRA Collaboration , F. Aharonian et al

Silica aerogels are important to be used as photon radiators in Cherenkov counters for high-energy-physics experiments because of their optical transparency and intermediate refractive indices between those of gases and liquids or solids.…

Instrumentation and Detectors · Physics 2023-10-10 Makoto Tabata

The sensitivity of a huge underground water/ice Cherenkov detector, such as PINGU in IceCube, to the neutrino mass hierarchy, the atmospheric mixing angle and its octant, is studied in detail. Based on the event rate decomposition in the…

High Energy Physics - Phenomenology · Physics 2015-06-18 Shao-Feng Ge , Kaoru Hagiwara

In this course we will give examples for experimental techniques used in particle physics experiments. After a short introduction, we will discuss applications in silicon microstrip detectors, wire chambers, and single photon detection in…

High Energy Physics - Experiment · Physics 2010-12-13 J. Engelfried

A novel photodetector based on a MCP-PMT vacuum tube with encapsulated CMOS ASIC has been tested at the CERN SPS high energy hadron beam, allowing single photon Cherenkov detection operating at 10$^4$ gain and with timing resolution of…

The cooling storage ring external-target experiment is a large-scale nuclear physics experiment, which aims to study the physics of heavy-ion collisions at low temperatures and high baryon densities. A beam monitor (BM) is placed in the…

The E864 experiment at BNL requires a beam counter and multiplicity detector system that can perform at an incident beam rate of 10^7 Au ions per second. We have developed and tested a 150 micrometer thick quartz Cherenkov beam counter and…

Instrumentation and Detectors · Physics 2009-10-31 P. Haridas , I. A. Pless , G. Van Buren , J. Tomasi , M. S. Z. Rabin , K. Barish , R. D. Majka

We review recent Z^0 physics results from SLD that use the Cherenkov Ring Imaging Detector for charged particle identification. The performance of the detector and likelihood method are described briefly. Several hadronization measurements…

High Energy Physics - Experiment · Physics 2008-11-26 D. Muller , representing the SLD Collaboration

A method to search for neutrino induced showers from gamma-ray bursts in the ANTARES detector is presented. ANTARES consists of a three-dimensional array of photosensitive devices that measure Cherenkov light induced by charged particles…

High Energy Astrophysical Phenomena · Physics 2015-05-27 Eleonora Presani

A first experimental test of tracking relativistic charged particles by `drifting' Cherenkov photons in a water-based optical time-projection chamber (OTPC) has been performed at the Fermilab Test Beam Facility. The prototype OTPC detector…

Instrumentation and Detectors · Physics 2016-02-17 E. Oberla , H. J. Frisch

Beam diagnostics are crucial for smooth accelerator operations. Many techniques rely on instrumentation in which the beam properties are significantly affected by the measurement. Novel approaches aim to use Cherenkov Diffraction Radiation…

This study presents the development of hydrophobic silica aerogel for use as a radiator in threshold-type Cherenkov counters. These counters are to be used for separating positrons and positive muons produced by kaon decay in the J-PARC…

Instrumentation and Detectors · Physics 2015-06-22 Makoto Tabata , Akihisa Toyoda , Hideyuki Kawai , Youichi Igarashi , Jun Imazato , Suguru Shimizu , Hirohito Yamazaki

Imaging Cherenkov detectors form the backbone of particle identification (PID) at the future Electron Ion Collider (EIC). Currently all the designs for the first EIC detector proposal use a dual Ring Imaging CHerenkov (dRICH) detector in…

Instrumentation and Detectors · Physics 2022-04-20 C. Fanelli , A. Mahmood

We recently proposed a new approach for the real-time monitoring of particle therapy treatments with the goal of achieving high sensitivities on the particle range measurement already at limited counting statistics. This method extends the…

The performance of Cherenkov instruments for the detection of very high energy gamma rays is ultimately limited by the fluctuations in the development of air showers. With particular emphasis on the angular resolution, the ultimate…

Astrophysics · Physics 2007-05-23 W. Hofmann

The Alpha Magnetic Spectrometer (AMS), whose final version AMS-02 is to be installed on the International Space Station (ISS) for at least 3 years, is a detector designed to measure charged cosmic ray spectra with energies up to the TeV…

Astrophysics · Physics 2007-10-05 Luísa Arruda , Fernando Barão , Rui Pereira

The Aerogel Ring Imaging Cherenkov (ARICH) counter serves as a particle identification device in the forward end-cap region of the Belle II spectrometer. It is capable of identifying pions and kaons with momenta up to $4 \, {\rm GeV}/c$ by…

Starting from 2018, the LHCb detector will be upgraded to operate at higher luminosity and extend its potential for new discoveries. The Ring Imaging Cherenkov (RICH) detectors are one of the key components for particle identification of…

Instrumentation and Detectors · Physics 2017-08-14 P. Carniti

Several methods can be used to perform statistical inference of primary composition of cosmic rays measured with water Cerenkov detectors as those in use at the Pierre Auger Southern Observatory. In the present work we assess the impact of…

The DIRC technology (Detection of Internally Reflected Cherenkov light) offers an excellent possibility to minimize the form factor of Cherenkov detectors in hermetic high energy detectors. The PANDA experiment at FAIR in Germany will…