English
Related papers

Related papers: Low-Background Experiments with High Pressure Gas …

200 papers

We developed a 12-liter volume neutron detector filled with the liquid scintillator EJ301 that measures neutrons in an underground laboratory where dark matter and neutrino experiments are located. The detector target is a cylindrical…

Instrumentation and Detectors · Physics 2015-06-15 C. Zhang , D. -M. Mei , P. Davis , B. Woltman , F. Gray

This thesis explores experimental and theoretical approaches to dark matter detection, from gas-based detectors to quantum sensors, tackling the challenge of identifying dark matter, which makes up 27% of the Universe's energy. It reviews…

Instrumentation and Methods for Astrophysics · Physics 2025-12-05 David Díez-Ibáñez

The usual nuclear recoil energy reconstruction employed by liquid xenon dark matter search experiments relies only on the primary scintillation photon signal. Energy reconstruction based on both the photon and electron signals yields a more…

Cosmology and Nongalactic Astrophysics · Physics 2012-11-13 Peter Sorensen

Light dark matter in the context of dark sector theories is an attractive candidate for the dark matter thought to make up the bulk of the mass of our universe. We explore here the possibility of using a low-pressure, negative-ion, time…

Instrumentation and Methods for Astrophysics · Physics 2019-03-27 D. P. Snowden-Ifft , J. L. Harton , N. Ma , F. G. Schuckman

A direct dark matter search is performed using fully-depleted high-resistivity CCD detectors . Due to their low electronic readout noise (RMS ~ 7 eV) these devices operate with a very low detection threshold of 40 eV, making the search for…

Instrumentation and Methods for Astrophysics · Physics 2015-05-28 J. Barreto , H. Cease , H. T. Diehl , J. Estrada , B. Flaugher , N. Harrison , J. Jones , B. Kilminster , J. Molina , J. Smith , T. Schwarz , A. Sonnenschein

XENON10 is an experiment designed to directly detect particle dark matter. It is a dual phase (liquid/gas) xenon time-projection chamber with 3D position imaging. Particle interactions generate a primary scintillation signal (S1) and…

We report the first results from an X-ray polarimeter with a micropattern gas proportional counter using an amorphous silicon active matrix readout. With 100% polarized X-rays at 4.5 keV, we obtain a modulation factor of 0.33 +/- 0.03,…

Instrumentation and Detectors · Physics 2015-06-26 J. K. Black , P. Deines-Jones , S. E. Ready , R. A. Street

The performance of scintillator counters with embedded wavelength-shifting fibers has been measured in the Fermilab Meson Test Beam Facility using 120 GeV protons. The counters were extruded with a titanium dioxide surface coating and two…

We developed a low-mass and high-efficiency charged particle detector for an experimental study of the rare decay $K_L \rightarrow \pi^0 \nu \bar{\nu}$. The detector is important to suppress the background with charged particles to the…

Instrumentation and Detectors · Physics 2016-02-03 D. Naito , Y. Maeda , N. Kawasaki , T. Masuda , H. Nanjo , T. Nomura , M. Sasaki , N. Sasao , S. Seki , K. Shiomi , Y. Tajima

Particle detectors that use liquid xenon (LXe) as detection medium are among the leading technologies in the search for dark matter weakly interacting massive particles (WIMPs). A key enabling element has been the low-energy detection…

We extend the study of the performance of a prototype two-phase liquid xenon WIMP dark matter detector to recoil energies below 20 keV. We demonstrate a new method for obtaining the best estimate of the energies of events using a calibrated…

Astrophysics · Physics 2008-11-26 T. Shutt , C. E. Dahl , J. Kwong , A. Bolozdynya , P. Brusov

We report a search for cosmic-ray boosted dark matter with protons using the 0.37 megaton$\times$years data collected at Super-Kamiokande experiment during the 1996-2018 period (SKI-IV phase). We searched for an excess of proton recoils…

High Energy Physics - Experiment · Physics 2023-08-31 Kamiokande Collaboration , K. Abe , Y. Hayato , K. Hiraide , K. Ieki , M. Ikeda , J. Kameda , Y. Kanemura , R. Kaneshima , Y. Kashiwagi , Y. Kataoka , S. Miki , S. Mine , M. Miura , S. Moriyama , Y. Nakano , M. Nakahata , S. Nakayama , Y. Noguchi , K. Okamoto , K. Sato , H. Sekiya , H. Shiba , K. Shimizu , M. Shiozawa , Y. Sonoda , Y. Suzuki , A. Takeda , Y. Takemoto , A. Takenaka , H. Tanaka , S. Watanabe , T. Yano , S. Han , T. Kajita , K. Okumura , T. Tashiro , T. Tomiya , X. Wang , J. Xia , S. Yoshida , G. D. Megias , P. Fernandez , L. Labarga , N. Ospina , B. Zaldivar , B. W. Pointon , E. Kearns , J. L. Raaf , L. Wan , T. Wester , J. Bian , N. J. Griskevich , W. R. Kropp , S. Locke , M. B. Smy , H. W. Sobel , V. Takhistov , A. Yankelevich , J. Hill , R. G. Park , B. Bodur , K. Scholberg , C. W. Walter , L. Bernard , A. Coffani , O. Drapier , S. El Hedri , A. Giampaolo , Th. A. Mueller , A. D. Santos , P. Paganini , B. Quilain , T. Ishizuka , T. Nakamura , J. S. Jang , J. G. Learned , K. Choi , S. Cao , L. H. V. Anthony , D. Martin , M. Scott , A. A. Sztuc , Y. Uchida , V. Berardi , M. G. Catanesi , E. Radicioni , N. F. Calabria , L. N. Machado , G. De Rosa , G. Collazuol , F. Iacob , M. Lamoureux , M. Mattiazzi , L. Ludovici , M. Gonin , G. Pronost , C. Fujisawa , Y. Maekawa , Y. Nishimura , M. Friend , T. Hasegawa , T. Ishida , T. Kobayashi , M. Jakkapu , T. Matsubara , T. Nakadaira , K. Nakamura , Y. Oyama , K. Sakashita , T. Sekiguchi , T. Tsukamoto , T. Boschi , F. Di Lodovico , J. Gao , A. Goldsack , T. Katori , J. Migenda , M. Taani , S. Zsoldos , Y. Kotsar , H. Ozaki , A. T. Suzuki , Y. Takeuchi , C. Bronner , J. Feng , T. Kikawa , M. Mori , T. Nakaya , R. A. Wendell , K. Yasutome , S. J. Jenkins , N. McCauley , P. Mehta , K. M. Tsui , Y. Fukuda , Y. Itow , H. Menjo , K. Ninomiya , J. Lagoda , S. M. Lakshmi , M. Mandal , P. Mijakowski , Y. S. Prabhu , J. Zalipska , M. Jia , J. Jiang , C. K. Jung , M. J. Wilking , C. Yanagisawa , M. Harada , H. Ishino , S. Ito , H. Kitagawa , Y. Koshio , F. Nakanishi , S. Sakai , G. Barr , D. Barrow , L. Cook , S. Samani , D. Wark , F. Nova , J. Y. Yang , M. Malek , J. M. McElwee , O. Stone , M. D. Thiesse , L. F. Thompson , H. Okazawa , S. B. Kim , J. W. Seo , I. Yu , A. K. Ichikawa , K. D. Nakamura , S. Tairafune , K. Nishijima , K. Iwamoto , K. Nakagiri , Y. Nakajima , N. Taniuchi , M. Yokoyama , K. Martens , P. de Perio , M. R. Vagins , M. Kuze , S. Izumiyama , M. Inomoto , M. Ishitsuka , H. Ito , T. Kinoshita , R. Matsumoto , Y. Ommura , N. Shigeta , M. Shinoki , T. Suganuma , K. Yamauchi , J. F. Martin , H. A. Tanaka , T. Towstego , R. Akutsu , V. Gousy-Leblanc , M. Hartz , A. Konaka , N. W. Prouse , S. Chen , B. D. Xu , B. Zhang , M. Posiadala-Zezula , D. Hadley , M. Nicholson , M. O'Flaherty , B. Richards , A. Ali , B. Jamieson , Ll. Marti , A. Minamino , G. Pintaudi , S. Sano , S. Suzuki , K. Wada

The dark matter search project by means of ultra high purity NaI(Tl) scintillator is now underdevelopment. An array of large volume NaI(Tl) detectors whose volume is 12.7 cm$\phi\times$12.7 cm is applied to search for dark matter signal. To…

The MiniCLEAN dark matter experiment will exploit a single-phase liquid-argon detector instrumented with photomultiplier tubes submerged in the cryogen with nearly 4pi coverage of a 500 kg (150 kg) target (fiducial) mass. The high light…

Instrumentation and Detectors · Physics 2011-10-06 Andrew Hime

We present low energy recoil detection results in the keV energy region, from measurements performed with the Spherical Proportional Counter (SPC). An ${}^{241}Am-{}^{9}{Be}$ fast neutron source is used in order to obtain neutron-nucleus…

Instrumentation and Detectors · Physics 2017-09-20 I. Savvidis , I. Katsioulas , C. Eleftheriadis , I. Giomataris , T. Papaevangellou

The CRESST experiment (Cryogenic Rare Event Search with Superconducting Thermometers) searches for dark matter via the phonon and light signals of elastic scattering processes in scintillating crystals. The discrimination between a possible…

Measurements with a bare p-type high purity germanium diode (HPGe) submerged in a 19 kg liquid argon (LAr) scintillation detector at MPIK Heidelberg are reported. The liquid argon--germanium system (LArGe) is operated as a 4$\pi$…

Instrumentation and Detectors · Physics 2008-11-26 M. Di Marco , P. Peiffer , S. Schönert

In this article the measurement results of proportional counter working characteristics filled with CF$_4$ and Xe ($0\div5$% Xe) additions at different pressures ($0.8\div14.8$ $at$) are presented. We have found that a bit of Xe addition…

Strong gravitational lensing is a powerful probe of the distribution of matter on sub-kpc scales. It can be used to test the existence of completely dark subhalos surrounding galaxies, as predicted by the standard cold dark matter model, or…

Cosmology and Nongalactic Astrophysics · Physics 2023-11-30 Ioana A. Zelko , Anna M. Nierenberg , Tommaso Treu

Dark Matter experiments are recently focusing their detection techniques in low-mass WIMPs, which requires the use of light elements and low energy threshold. In this context, we describe the TREX-DM experiment, a low background…

Instrumentation and Detectors · Physics 2015-09-08 F. J. Iguaz , J. G. Garza , F. Aznar , J. F. Castel , S. Cebrian , T. Dafni , J. A. Garcia , I. G. Irastorza , A. Lagraba , G. Luzon , A. Peiro
‹ Prev 1 3 4 5 6 7 10 Next ›