We have developed a photon counting detector system for combined neutron and gamma radiography which can determine position, time and intensity of a secondary photon flash created by a high-energy particle or photon within a scintillator…

We present the development of a single-photon detector and the connected read-out electronics. This `hybrid' detector is based on a vacuum tube, transmission photocathode, microchannel plate and a pixelated CMOS read-out anode encapsulating…

Instrumentation and Detectors · Physics 2022-07-06 J. A. Alozy , N. V. Biesuz , M. Campbell , V. Cavallini , A. Cotta Ramusino , M. Fiorini , M. Guarise , X. Llopart Cudie

Distinguishing photon-arrival time and position is crucial for advancing quantum technology. However, capturing spatial and temporal information efficiently remains challenging. Here, we present a novel photon-detection technique to achieve…

Quantum Physics · Physics 2024-07-24 Ozora Iso , Kensuke Miyajima , Ryosuke Shimizu

The superconducting nanowire single photon detector (SNSPD) is a leading technology for quantum information science applications using photons, and they are finding increasing uses in photon-starved classical imaging applications. Critical…

Instrumentation and Detectors · Physics 2018-08-01 Clinton Cahall , Daniel J. Gauthier , Jungsang Kim

This paper will discuss a new method of signal read-out from photon detectors in ultra-large, underground liquid argon time projection chambers. In this design, the signal from the light collection system is coupled via capacitive plates to…

Instrumentation and Detectors · Physics 2016-04-13 Z. Moss , M. Toups , L. Bugel , G. H. Collin , J. M. Conrad

A highly sensitive photodetection system with a detection limit of 1 photon/s was developed. This system uses a commercially available 200-mm-diameter silicon avalanche photodiode (APD) and an in-house-developed ultralow-noise readout…

Quantum Physics · Physics 2009-11-11 Makoto Akiba , Mikio Fujiwara , Masahide Sasaki

The Large High Altitude Air Shower Observatory is in the R&D phase, in which the Water Cherenkov Detector Array is an important part. The signals of Photo-Multiplier Tubes would vary from single photo electron to 4000 photo electrons, and…

Instrumentation and Detectors · Physics 2019-07-09 Lei Zhao , Weihao Wu , Jianfeng Liu , Yu Liang , Jiajun Qin , Li Yu , Shubin Liu , Qi An

Fast timing detectors are an essential element in the experimental setup for time-of-flight (ToF) mass measurements of unstable nuclei. We have upgraded the scintillator detectors used in experiments at the National Superconducting…

A segmented-scintillator-based implantation detector was developed to study the energy distribution of beta-delayed neutrons emitted from exotic isotopes. The detector comprises a 34 $\times$ 34 YSO scintillator coupled to an 8 $\times$ 8…

An array of DEPFET pixels is one of several concepts to implement an active pixel sensor. Similar to PNCCD and SDD detectors, the typically 0.45 mm thick silicon sensor is fully depleted by the principle of sideward depletion. They have…

Instrumentation and Methods for Astrophysics · Physics 2023-04-05 Norbert Meidinger , Johannes Müller-Seidlitz

We have constructed and tested a 2d position sensitive parallel-plate gas ionization chamber with scanned charge transfer readout. The scan readout method described here is based on the development of a new position dependent charge…

Instrumentation and Detectors · Physics 2009-11-10 F. Gomez , A. Iglesias , R. Lobato , J. Mosquera , J. Pardo , J. Pena , A. Pazos , M. Pombar , A. Rodriguez

We have developed a position response calibration method for a micro-channel plate (MCP) detector with a delay-line anode position readout scheme. Using an {\em in situ} calibration mask, an accuracy of 8~$\mu$m and a resolution of…

We present the development of a second generation digital readout system for photon counting microwave kinetic inductance detector (MKID) arrays operating in the optical and near-IR wavelength bands. Our system retains much of the core…

Micro-channel-plate-based photo-detectors are unique in being capable of covering areas of many square-meters while providing sub-millimeter space resolution, time resolutions of less than 10 picoseconds for charged particles, time…

Instrumentation and Detectors · Physics 2020-10-28 Jinseo Park , Fangjian Wu , Evan Angelico , Henry J. Frisch , Eric Spieglan

A double-layer silicon detector consisting of two 500micron-thick silicon PIN photodiodes with independent readouts was mounted in a vacuum chamber and tested with X-ray sources. The detector is sensitive from 1-30 keV with an effective…

Astrophysics · Physics 2009-11-11 Hua Feng , Philip Kaaret , Hans Andersson

A new design for the anode of a time projection chamber, consisting of a charge-detecting "tile", is investigated for use in large scale liquid xenon detectors. The tile is produced by depositing 60 orthogonal metal charge-collecting…

Instrumentation and Detectors · Physics 2018-01-23 nEXO Collaboration , M. Jewell , A. Schubert , W. R. Cen , J. Dalmasson , R. DeVoe , L. Fabris , G. Gratta , A. Jamil , G. Li , A. Odian , M. Patel , A. Pocar , D. Qiu , Q. Wang , L. J. Wen , J. B. Albert , G. Anton , I. J. Arnquist , I. Badhrees , P. Barbeau , D. Beck , V. Belov , F. Bourque , J. P. Brodsky , E. Brown , T. Brunner , A. Burenkov , G. F. Cao , L. Cao , C. Chambers , S. A. Charlebois , M. Chiu , B. Cleveland , M. Coon , A. Craycraft , W. Cree , M. Côté , T. Daniels , S. J. Daugherty , J. Daughhetee , S. Delaquis , A. Der Mesrobian-Kabakian , T. Didberidze , J. Dilling , Y. Y. Ding , M. J. Dolinski , A. Dragone , W. Fairbank , J. Farine , S. Feyzbakhsh , R. Fontaine , D. Fudenberg , G. Giacomini , R. Gornea , E. V. Hansen , D. Harris , M. Hasan , M. Heffner , E. W. Hoppe , A. House , P. Hufschmidt , M. Hughes , J. Hößl , Y. Ito , A. Iverson , X. S. Jiang , S. Johnston , A. Karelin , L. J. Kaufman , T. Koffas , S. Kravitz , R. Krücken , A. Kuchenkov , K. S. Kumar , Y. Lan , D. S. Leonard , S. Li , Z. Li , C. Licciardi , Y. H. Lin , R. MacLellan , T. Michel , B. Mong , D. Moore , K. Murray , R. J. Newby , Z. Ning , O. Njoya , F. Nolet , K. Odgers , M. Oriunno , J. L. Orrell , I. Ostrovskiy , C. T. Overman , G. S. Ortega , S. Parent , A. Piepke , J. -F. Pratte , V. Radeka , E. Raguzin , T. Rao , S. Rescia , F. Retiere , A. Robinson , T. Rossignol , P. C. Rowson , N. Roy , R. Saldanha , S. Sangiorgio , S. Schmidt , J. Schneider , D. Sinclair , K. Skarpaas , A. K. Soma , G. St-Hilaire , V. Stekhanov , T. Stiegler , X. L. Sun , M. Tarka , J. Todd , T. Tolba , R. Tsang , T. Tsang , F. Vachon , V. Veeraraghavan , G. Visser , J. -L. Vuilleumier , M. Wagenpfeil , M. Weber , W. Wei , U. Wichoski , G. Wrede , S. X. Wu , W. H. Wu , Z. Xuan , L. Yang , D. Yayun , Y. -R. Yen , O. Zeldovich , X. Zhang , J. Zhao , N. Zhe , Y. Zhou , T. Ziegler

The detector of TRopIcal DEep-sea Neutrino Telescope (TRIDENT) will use large-area silicon photomultiplier (SiPM) arrays combined with photomultiplier tubes to boost photon detection efficiency and pointing capability. An…

Instrumentation and Detectors · Physics 2025-02-06 M. X. Wang , Y. Liu , Y. Q. Tan , J. N. Tang , W. H. Wu , D. L. Xu , W. Zhi , Z. Z. Zhou

Discovering the microscopic composition of dark matter is one of the most important open problems in physics today. Axions are a leading candidate to be dark matter; however, a search of the full range of all likely axion masses is hampered…

We demonstrate a 64-pixel free-space-coupled array of superconducting nanowire single photon detectors optimized for high detection efficiency in the near-infrared range. An integrated, readily scalable, multiplexed readout scheme is…

Instrumentation and Detectors · Physics 2015-06-11 M. S. Allman , V. B. Verma , M. Stevens , T. Gerrits , R. D. Horansky , A. E. Lita , F. Marsili , A. Beyer , M. D. Shaw , D. Kumor , R. Mirin , S. W. Nam

A 760 $\times$ 760 $\times$ 30 mm$^3$ plastic scintillation detector viewed by photomultiplier tubes (PMTs) from four corners has been developed, and the detector has been tested with cosmic rays and $\gamma$ rays. A position-independent…

Instrumentation and Detectors · Physics 2016-08-03 Shu-wen Tang , Yu-hong Yu , Yong Zhou , Zhi-yu Sun , Xue-heng Zhang , Shi-tao Wang , Ke Yue , Long-xiang Liu , Fang Fang , Duo Yan , Yu Sun , Zhao-min Wang