We present first results of a new heterodyne spectrometer dedicated to high-resolution spectroscopy of molecules of astrophysical importance. The spectrometer, based on a roomtemperature heterodyne receiver, is sensitive to frequencies…

Instrumentation and Methods for Astrophysics · Physics 2018-09-12 Nadine Wehres , Bettina Heyne , Frank Lewen , Marius Hermanns , Bernhard Schmidt , Christian Endres , Urs U. Graf , Daniel R. Higgins , Stephan Schlemmer

Resonant frequencies of the two-dimensional plasma in FETs increase with the reduction of the channel dimensions and can reach the THz range for sub-micron gate lengths. Nonlinear properties of the electron plasma in the transistor channel…

Monolithically integrated, antenna-coupled field-effect transistors (TeraFETs) are rapid and sensitive detectors for the terahertz range (0.3-10~THz) that can operate at room temperature. We conducted experimental characterizations of a…

Fast, room temperature imaging at THz and sub-THz frequencies is an interesting feature which could unleash the full potential of plenty applications in security, healthcare and industrial production. In this Letter we introduce…

Instrumentation and Detectors · Physics 2022-02-25 Leonardo Vicarelli , Alessandro Tredicucci , Alessandro Pitanti

We present radio-frequency thermometry based on a tunnel junction between a superconductor and proximitized normal metal. It allows operation in a wide range of biasing conditions. We demonstrate that the standard finite-bias quasiparticle…

Mesoscale and Nanoscale Physics · Physics 2018-11-28 Bayan Karimi , Jukka P. Pekola

Temperature-based radiation detectors are an essential tool for long optical wavelengths detection even if they often suffer from important bandwidth limitations. Their responsivity, and hence their noise equivalent power (NEP), typically…

A room-temperature mid-infrared (9 um) heterodyne system based on high-performance unipolar optoelectronic devices is presented. The local oscillator (LO) is a quantum cascade laser, while the receiver is an antenna coupled quantum well…

Photon detection with quantum-level sensitivity is particularly challenging in the terahertz regime (0.1-10 THz), which contains ~98% of all the photons existing in the universe. Near-quantum-limited terahertz spectrometry has so far only…

Instrumentation and Detectors · Physics 2018-06-15 Ning Wang , Semih Cakmakyapan , Yen-Ju Lin , Hamid Javadi , Mona Jarrahi

Infrared (IR) radiation detectors are used in numerous applications from thermal imaging to spectroscopic gas sensing. Obtaining high speed and sensitivity, low-power operation and cost-effectiveness with a single technology remains to be a…

Semiconductor nanowire field-effect transistors represent a promising platform for the development of room-temperature (RT) terahertz (THz) frequency light detectors due to the strong nonlinearity of their transfer characteristics and their…

Optical excitation and subsequent decay of graphene plasmons can produce a significant increase in charge-carrier temperature. An efficient method to convert this temperature elevation into a measurable electrical signal at room temperature…

Mesoscale and Nanoscale Physics · Physics 2018-08-29 Qiushi Guo , Renwen Yu , Cheng Li , Shaofan Yuan , Bingchen Deng , F. Javier García de Abajo , Fengnian Xia

Sensitive detection of terahertz (THz) radiation is fundamental to progress in spectroscopy, advanced wireless communication, and the realization of emerging quantum technologies. However, the intrinsically low photon energies in the THz…

Mid-infrared spectrum is a critical tool for chemical analysis, industrial inspection, environment, and other fields due to its rich chemical bond information. However, the complicated growth or fabrication procedures of existing…

Spectroscopy and imaging in the mid-infrared (2.5 $\mu$m $\sim$ $\lambda$ $\sim$ 25 $\mu$m) is bedevilled by the presence of a strong 300 K thermal background at room temperature that makes IR detectors decades noisier than can be readily…

Quantum Physics · Physics 2023-11-28 Yue Ma , Nathan Gemmell , Emma Pearce , Rupert Oulton , Chris Phillips

We study the use of a thermoelectric junction as a thermal radiation detector in the calorimetric regime, where single radiation bursts can be separated in time domain. We focus especially on the case of a large thermoelectric figure of…

Mesoscale and Nanoscale Physics · Physics 2018-10-17 Subrata Chakraborty , Tero T. Heikkilä

Chemical doping of bulk black phosphorus is a well-recognized way to reduce surface oxidation and degradation. Here, we report on the fabrication of terahertz frequency detectors consisting of an antenna-coupled field-effect transistor…

Mesoscale and Nanoscale Physics · Physics 2019-03-08 Leonardo Viti , Antonio Politano , Kai Zhang , Miriam Serena Vitiello

A sensitive photoacoustic detection approach employing a silicon cantilever is investigated for power measurement of electromagnetic radiation. The technique which is actuated by pressure waves generated through radiation-induced heat,…

Instrumentation and Detectors · Physics 2021-01-07 Sucheta Sharma , Toni Laurila , Jussi Rossi , Juho Uotila , Markku Vainio , Farshid Manoocheri , Erkki Ikonen

High-sensitivity long-wave infrared (LWIR) detection is crucial for observing weak thermal radiation. Recently, the Poisson bolometer has been proposed as a fundamentally new platform for uncooled infrared detection. In contrast to…

We demonstrate AFM imaging with a microcantilever force transducer where an integrated superconducting microwave resonant circuit detects cantilever deflection using the principles of cavity optomechanics. We discuss the detector…

Frequency-selective or even frequency-tunable Terahertz (THz) photodevices are critical components for many technological applications that require nanoscale manipulation, control and confinement of light. Within this context, gate-tunable…