Related papers: First Tests of Thick GEMs with Electrodes Made of …
We report the status of R&D on large triple-GEM detectors for a forward tracker (FT) in an experiment at a future Electron Ion Collider (EIC) that will improve our understanding of QCD. We have designed a detector prototype specifically…
We have demonstrated that hole-type gaseous detectors, GEMs and capillary plates, can operate up to 77 K. For example, a single capillary plate can operate at gains of above 10E3 in the entire temperature interval between 300 until 77 K.…
Gas Electron Multiplier (GEM) technology is being considered for the forward muon upgrade of the CMS experiment in Phase 2 of the CERN LHC. Its first implementation is planned for the GE1/1 system in the $1.5 < \mid\eta\mid < 2.2$ region of…
A new concept for a hybrid structure gaseous detector module with ion backflow suppression for the time projection chamber in a future circular collider is presented. It is a hybrid structure cascaded Gas Electron Multiplier (GEM) with a…
The Gas Electron Multiplier detectors with wire and metallic electrodes, with a gas filling in the gap between them were proposed and tested. The main advantage of these Gas Electron Multipliers compared to standard ones consists in their…
We have previously reported on the construction and successful operation of the novel double phase Liquid Argon Large Electron Multiplier Time Projection Chamber (LAr LEM-TPC). This detector concept provides a 3D-tracking and calorimetric…
The performance of triple-GEM detectors in He+N2 gas mixtures is studied in the range of 1-10 atm. The results obtained are relevant in the field of minimization of ionic space-charge effect in the TPC and neutron detection.
We developed a prototype time projection chamber using gas electron multipliers (GEM-TPC) for high energy heavy ion collision experiments. To investigate its performance, we conducted a beam test with 3 kinds of gases (Ar(90%)-CH4(10%),…
We present a gas selection for Xe-based gas electron multiplier (GEM) detectors, Gas Multiplier Counters (GMCs) onboard the CubeSat X-ray observatory NinjaSat. To achieve an energy bandpass of 2-50 keV, we decided to use a Xe-based gas…
The architecture of the novel MPGD-based photon detectors of COMPASS RICH-1 consists in a large-size hybrid MPGD multilayer layout combining two layers of Thick-GEMs and a bulk resistive MICROMEGAS. Concerning biasing voltage, the…
We present avalanche gain and associated resolution measurements recorded with a $^4$He:CO$_2$ (70:30) gas mixture and pure SF$_6$, a Negative Ion (NI) gas. SF$_6$ is of particular interest to the directional dark matter detection…
A cylindrical GEM detector is under development, to serve as an upgraded inner tracker at the BESIII spectrometer. It will consist of three layers of cylindrically-shaped triple GEMs surrounding the interaction point. The experiment is…
The first operation of GEM gas gain elements in negative ion gas mixtures is reported. Gains up to several thousand were obtained from single-stage GEMs in carbon disulfide vapor at low pressure, and in mixtures of carbon disulfide with…
Micro-Pattern Gaseous Detectors (MPGDs) such as Micromegas or GEM are used in particle physics experiments for their capabilities in particle tracking at high rates. Their excellent position resolutions are well known but their energy…
Systematic studies on the gain and the energy resolution have been carried out varying the voltage across the GEM foils for both single mask and double mask triple GEM detector prototypes. Variation of the gain and the energy resolution…
The Helium-3 shortage and the growing interest in neutron science constitute a driving factor in developing new neutron detection technologies. In this work, we report the development of a double-GEM detector prototype that uses a…
The gas electron multiplier produced with the polyimide film 100 um thick. The maximum gas gain obtained with gas mixture Ar/CH4(91/9) was 5000. No decrease of gas gain with rates up to 2\cdot10^4 1/(mm^2 s) was observed. The possibility of…
A technique for measuring high-energy electrons using Si detectors of various thicknesses that are much smaller than the range of the examined electrons is presented. The advantages of the method are discussed on the basis of…
Transition Radiation Detectors (TRDs) are useful for electron identification and hadron suppression in high energy nuclear and particle physics experiments. Conventional wire-chamber TRDs face operational limitations due to space charge…
The purpose of this project is to investigate the use of charge couple devices (CCDs) to detect electrons directly. This can be done in transmission electron microscopy (TEM) for electrons over 100 KeV, but for space plasma instruments,…