Related papers: First Tests of Thick GEMs with Electrodes Made of …
We report on the manufacture of a first batch of approximately 2,000 Gas Electron Multipliers (GEMs) using 3M's fully automated roll to roll flexible circuit production line. This process allows low-cost, reproducible fabrication of a high…
The characteristics of triple GEM detectors have been studied systematically by using cosmic ray muons. The minimum ionizing particle (MIP) spectra has been taken for different GEM voltage setting. Efficiency of GEM detector has been…
Gas Electron Multiplier (GEM) is a cutting edge Micro Pattern Gaseous detector (MPGD) technology suitable as tracking device in high rate Heavy-Ion (HI) experiments for their good spatial resolution and most importantly high rate handling…
An approximate formula has been derived for gain fluctuations in cascaded gaseous detectors such as GEM-s, based on the assumption that the charge collection, avalanche formation and extraction steps are independent cascaded processes. In…
Gas Electron Multipliers (GEM) are an interesting technology under consideration for the future upgrade of the forward region of the CMS muon system, specifically in the $1.6<| \eta |<2.4$ endcap region. With a sufficiently fine…
GEM are widely used as amplification stages in gaseous detectors exposed to high rates. The GEM consists of a polyimide foil which is coated by two thin copper layers. Charges collected into the holes or created during the amplification…
A comprehensive study, supported by systematic measurements and numerical computations, of the intrinsic limits of multi-GEM detectors when exposed to very high particle fluxes or operated at very large gains is presented. The observed…
The performance of a two-phase Ar avalanche detector in a single electron counting mode was studied, with regard to potential application in coherent neutrino-nucleus scattering and dark matter search experiments. The detector comprised of…
In this work, we study the response of single layer Thick GEM (THGEM) detector to p/${\pi^+}$ at E3 line of Beijing Test Beam Facility. In our experiment, the drift gap of THGEM Detector is 4mm, and the working gas is Ar/3% iso. Result…
We report on the properties of thick GEM-like (THGEM) electron multipliers made of 0.4 mm thick double-sided Cu-clad G-10 plates, perforated with a dense hexagonal array of 0.3 mm diameter drilled holes. Photon detectors comprising THGEMs…
We study the performance of Gas Electron Multipliers (GEMs) in gaseous He, Ne and Ne+H2 at temperatures in the range of 2.6-293 K. In He, at temperatures between 62 and 293 K, the triple-GEM structures often operate at rather high gains,…
We describe a new micro-pattern gas detector structure comprising a multi-layer hole-type multiplier (M-THGEM) combined with two in-built electrode meshes: the Multi-Mesh THGEM-type multiplier (MM-THGEM). Suitable potential differences…
Controlled etching of copper electrodes in Gas Electron Multiplier foils allows a reduction of the material budget by more than a factor of two for a triple-GEM detector. Detectors making use of thinned foils provide performances similar to…
Gas electron multipliers (GEMs) have been overcoated with a high resistivity 10e14 - 10e15 Ohms / square amorphous carbon layer. The coating avoids charging up of the holes and provides a constant gain immediately after switching on…
A sealed high gas pressure detector working in pure argon is assembled. It consists of a 5 cm $\times$ 5 cm PCB THGEM (THick Gaseous Electron Multipliers). The detector structure and experimental setup are described. The performances under…
We have developed and successfully used several innovative designs of detectors with solid photocathodes. The main advantage of these detectors is that rather high gains (>10E4) can be achieved in a single multiplication step. This is…
Gas detector are very light instrument used in high energy physics to measure the particle properties: position and momentum. Through high electric field is possible to use the Gas Electron Multiplier (GEM) technology to detect the charged…
A new type of resistive plate chamber with thin-film electrodes based on diamond-like carbon is under development for background identification in the MEG II experiment. Installed in a low-momentum and high-intensity muon beam, the detector…
To extend the acceptance of the CMS muon spectrometer to the region 2.4 $<|\eta|<$ 2.8, stacks of triple-GEM chambers, forming the ME0 station, are planned for the CMS Phase 2 Upgrade. These large-area micro-pattern gaseous detectors must…
In this work we investigate three variants of single amplification-stage detector elements; they comprise THGEM electrodes closed at their bottom with metallic or resistive anodes to form WELL-type configurations. We present the results of…