English
Related papers

Related papers: Detector performance of the NEWAGE experiment

200 papers

The chamber for direct detection of WIMP with mass <0.5 Gev/c2 was developed. The chamber is filled with gas mixture Ne+10%H2 (0-1bar)+0,15ppm Ge(CH3)4. For events detection used GEM+pin-anodes , which provides the energy threshold about…

Instrumentation and Methods for Astrophysics · Physics 2015-12-04 B. M. Ovchinnikov , I. I. Tkachev , V. V. Parusov

Gaseous Time Projection Chambers with Optical Readout are sensitive detectors suitable for 3D measurement of low-energy O(1 keV) particles and are proposed for detecting rare events such as Dark Matter particle interactions. The CYGNO…

Dual-phase time projection chambers (TPCs) filled with the liquid noble gas xenon (LXe) are currently the most sensitive detectors searching for interactions of WIMP dark matter in a laboratory-based experiment. This is achieved by…

Instrumentation and Methods for Astrophysics · Physics 2014-08-08 Marc Schumann

We present work on the detection of neutral particles via nuclear recoils in gas-filled Time Projection Chambers (TPCs). We employ Gas Electron Multipliers (GEMs) to amplify the signal and silicon pixel electronics to detect the avalanche…

Direct detection of weakly interacting massive particles (WIMPs) can provide strong evidence of their existence and the directional method would have an advantage over other methods to detect the clear signal of WIMPs. Time projection…

The MIMAC project is a multi-chamber detector for Dark Matter search, aiming at measuring both track and ionization with a matrix of micromegas micro-TPC filled with He3 and CF4. Recent experimental results on the first measurements of the…

Cosmology and Nongalactic Astrophysics · Physics 2009-09-01 F. Mayet , O. Guillaudin , C. Grignon , C. Koumeir , D. Santos , P. Colas , I. Giomataris

Understanding the ability to measure and discriminate particle events at the lowest possible energy is an essential requirement in developing new experiments to search for weakly interacting massive particle (WIMP) dark matter. In this…

The Neutron Induced Fission Fragment Tracking Experiment (NIFFTE) is a double-sided Time Projection Chamber (TPC) with micromegas readout designed to measure the energy-dependent neutron-induced fission cross sections of the major and minor…

Directional detection of Dark Matter allows for unambiguous direct detection of WIMPs as well as discrimination between various Dark Matter models in our galaxy. The DMTPC detector is a low-pressure TPC with optical readout designed for…

Recent computational results suggest that directional dark matter detectors have potential to probe for WIMP dark matter particles below the neutrino floor. The DRIFT-IId detector used in this work is a leading directional WIMP search time…

A new type of Time Projection Chamber (TPC) has been proposed for the upgrade of the ALICE (A Large Ion Collider Experiment at CERN) so as to cater to the high luminosity environment expected at the Large Hadron Collider (LHC) facility in…

Instrumentation and Detectors · Physics 2015-11-17 Saikat Biswas

With the development of the circular collider, it is necessary to make accurate physics experimental measurements of particle properties at higher luminosity $Z$ pole. Micro-pattern gaseous detectors (MPGDs), which contain Gaseous Electron…

Instrumentation and Detectors · Physics 2021-09-22 Zhiyang Yuan , Huirong Qi , Yue Chang , Ye Wu , Hongyu Zhang , Jian Zhang , Yuanbo Chen , Yiming Cai , Yulan Li , Zhi Deng , Hui Gong

Direction-sensitive WIMP dark matter searches may help overcome the challenges faced by direct dark matter detection experiments. In particular, directional detectors should be able to clearly differentiate a dark matter signal from…

Instrumentation and Detectors · Physics 2014-02-04 Steven Ross

Weakly Interacting Massive Particles (WIMPs) are one of the best motivated candidates to compose the Dark Matter of the Universe. The lack of experimental confirmation by direct detection experiments or collider searches has ruled out…

Instrumentation and Detectors · Physics 2025-07-04 Oscar Perez

A tracking detector system has been constructed with an innovative approach to the classical multi-wire proportional chamber concept, using contemporary technologies. The detectors, covering an area of 0.58 square meters each, are optimized…

Instrumentation and Detectors · Physics 2016-08-30 Dezső Varga , Gábor Nyitrai , Gergő Hamar , László Oláh

A Time Projection Chamber (TPC) is an ideal device for the detection of charged particle tracks in a large volume covering a solid angle of almost $4\pi$. The high density of hits on a given particle track facilitates the task of pattern…

In view of a possible application as a charge-particle track readout for an Active-Target Time Projection Chamber (AT-TPC), the operational properties and performances of a hybrid Micro-Pattern Gaseous Detector (MPGD) were investigated in…

Instrumentation and Detectors · Physics 2015-12-23 Marco Cortesi , Wolfgang Mittig , Daniel Bazin , Saul Beceiro-Novo , John Yurkon , Rim Soussi Tanani , Michael Wolff , Andreas Stolz

The CDEX-1 experiment conducted a search of low-mass (< 10 GeV/c2) Weakly Interacting Massive Particles (WIMPs) dark matter at the China Jinping Underground Laboratory using a p-type point-contact germanium detector with a fiducial mass of…

‹ Prev 1 3 4 5 6 7 10 Next ›