Related papers: Edgeless Silicon Detectors for the TOTEM Experimen…
The Linear Collider TPC collaboration constructed a Large Prototype TPC (LPTPC) which is now installed at the EUDET facility, in DESY. The SiLC-collaboration (Silicon for the Linear Collider) will install position sensitive silicon strip…
Corrosion of metal structures is often prevented using cathodic protection systems, that employ sacrificial anodes that corrode more preferentially relative to the metal to be protected. In-situ monitoring of these sacrificial anodes during…
We have developed a new design of a GEM-like detector with single-layer electrodes made of a resistive kapton. This detector can operate at gains close to 10E5 even in pure Ar and Ne and if transited to discharges at higher gains they, due…
This paper presents the design and fabrication of batch-processed cantilever probes with electrical shielding for scanning microwave impedance microscopy. The diameter of the tip apex, which defines the electrical resolution, is less than…
Kaonic atoms, formed when a negatively charged kaon replaces an electron, provide a sensitive probe of the low-energy strong interaction via precision X-ray spectroscopy. The SIDDHARTA-2 experiment at the DA$\Phi$NE collider employs…
The scientific detector systems for the ESO ELT first-light instruments, HARMONI, MICADO, and METIS, together will require 27 science detectors: seventeen 2.5 $\mu$m cutoff H4RG-15 detectors, four 4K x 4K 231-84 CCDs, five 5.3 $\mu$m cutoff…
The Circular Electron Positron Collider (CEPC) has been proposed to enable more thorough and precise measurements of the properties of Higgs, W, and Z bosons, as well as to search for new physics. In response to the stringent performance…
The upgrade of the Resistive Plate Chamber (RPC) detector, in order to increase the detector rate capability and to be able to work efficiently in high rate environment, consists in the reduction of the operating voltage along with the…
In the last two decades we have assisted to a rush towards finding a He3-replacing technology capable of detecting neutrons emitted from fissile isotopes. The demand stems from applications like nuclear war-head screening or preventing…
Silicon pixel detectors produced according to the ATLAS Pixel Detector design were tested in a beam at CERN in the framework of the ATLAS collaboration. The detectors used n+/n sensors with oxygenated silicon substrates. The experimental…
To fully exploit the HERA-II upgrade,the ZEUS experiment has installed a Micro Vertex Detector (MVD) using n-type, single-sided, silicon micro-strip sensors with capacitive charge division. The sensors have a readout pitch of 120…
The Low-Gain Avalanche Diode (LGAD) is a new silicon detector and holds wide application prospects in particle physics experiments due to its excellent timing resolution. The LGAD with a pixel size of 1.3 mm $\times$ 1.3 mm was used to…
The high-luminosity high-energy Electron-Ion Collider (EIC) to be built at Brookhaven National Laboratory (BNL) will provide a clean environment to study several fundamental questions in the high energy and nuclear physics fields. A high…
As part of its HL-LHC upgrade program, the CMS collaboration is replacing its existing endcap calorimeters with a high-granularity calorimeter (CE). The new calorimeter is a sampling calorimeter with unprecedented transverse and…
The CMS GEM collaboration is considering Gas Electron Multipliers (GEMs) for upgrading the CMS forward muon system in the 1.5<|eta|<2.4 endcap region. GEM detectors can provide precision tracking and fast trigger information. They would…
The appearance of direct electron detectors marked a new era for electron diffraction. Their high sensitivity and low noise opens the possibility to extend electron diffraction from transmission electron microscopes (TEM) to lower energies…
Selene is the attempt to implement a new scheme for high-intensity specular reflectometry. Instead of a highly collimated beam one uses a convergent beam covering a large angular range. The angular resolution is then performed by a…
Following the Phase-II upgrade during Long Shutdown (LS3), the LHC aims to reach a peak instantaneous luminosity of $7.5\times 10^{34}$cm$^{-2}$s$^{-1}$, which corresponds to an average of around 200 inelastic proton-proton collisions per…
Feature sizes in integrated circuits have decreased substantially over time, and it has become increasingly difficult to three-dimensionally image these complex circuits after fabrication. This can be important for process development,…
The SiD Detector is one of two detector designs for the future International Linear Collider (ILC) that were validated in 2012 SiD features a compact, cost-constrained design for precision Higgs and other measurements, and sensitivity to a…