A highly sensitive photodetection system with a detection limit of 1 photon/s was developed. This system uses a commercially available 200-mm-diameter silicon avalanche photodiode (APD) and an in-house-developed ultralow-noise readout…

Quantum Physics · Physics 2009-11-11 Makoto Akiba , Mikio Fujiwara , Masahide Sasaki

We have developed a new type of particle identification device, called an Aerogel Ring Imaging Cherenkov (ARICH) counter, for the Belle II experiment. It uses silica aerogel tiles as Cherenkov radiators. For detection of Cherenkov photons,…

The architecture of the novel MPGD-based photon detectors of COMPASS RICH-1 consists in a large-size hybrid MPGD multilayer layout combining two layers of Thick-GEMs and a bulk resistive MICROMEGAS. Concerning biasing voltage, the…

We describe a novel photon detector which operates under an intense flux of neutrons. It is composed of lead-aerogel sandwich counter modules. Its salient features are high photon detection efficiency and blindness to neutrons. As a result…

Instrumentation and Detectors · Physics 2016-06-21 Y. Maeda , N. Kawasaki , T. Masuda , H. Morii , D. Naito , Y. Nakajima , H. Nanjo , T. Nomura , N. Sasao , S. Seki , K. Shiomi , T. Sumida , Y. Tajima

The Cherenkov Imaging Telescope Integrated Read Out Chip (CITIROC) is a 32-channel fully analogue front-end ASIC dedicated to the read-out of silicon photo-multiplier (SiPM) sensors that can be used in a variety of experiments with…

Instrumentation and Detectors · Physics 2020-06-17 Domenico Impiombato , Alberto Segreto , Osvaldo Catalano , Salvatore Giarrusso , Teresa Mineo

The limitations in performance of the present RICH system in the LHCb experiment are given by the natural chromatic dispersion of the gaseous Cherenkov radiator, the aberrations of the optical system and the pixel size of the photon…

Instrumentation and Detectors · Physics 2018-03-14 C. D'Ambrosio , R. Cardinale , S. Easo , A. Petrolini , O. Ullaland

Silicon photomultipliers are very versatile photo detectors due to their high photon detection efficiency, fast response, single photon counting capability, high amplification, and their insensitivity to magnetic fields. At our institute we…

Nuclear Experiment · Physics 2015-05-18 G. S. M. Ahmed , P. Bühler , J. Marton , K. Suzuki

TORCH is a novel time-of-flight detector, designed to provide charged particle identification of pions, kaons and protons in the momentum range 2-20 GeV/c over a 9.5 m flight path. A detector module, comprising a 10mm thick quartz plate,…

Novel gaseous detectors of single photons for RICH applications have been developed and installed on COMPASS RICH-1 in 2016. They have a hybrid architecture consisting of two staggered THGEM layers (one equipped with a CsI photoconverting…

A prototype of a position sensitive photo-detector with 5.6 x 5.6 cm2 detection area readout with 64 Hamamatsu MPPCs (S10931-100P) with 3 x 3 mm2 active area each has been built and tested. The photo-sensors are arranged in a 8 x 8 array…

Instrumentation and Detectors · Physics 2015-06-03 L. Gruber , G. S. M. Ahmed , S. E. Brunner , P. Bühler , J. Marton , K. Suzuki

The STAR-RICH detector extends the particle identification capapbilities of the STAR experiment for charged hadrons at mid-rapidity. This detector represents the first use of a proximity-focusing CsI-based RICH detector in a collider…

A prototype detector is being developed which combines the functions of a Time Projection Chamber for charged particle tracking and a Cherenkov detector for particle identification. The TPC consists of a 10x10x10 cm3 drift volume where the…

Instrumentation and Detectors · Physics 2015-12-18 Craig Woody , Babak Azmoun , Richard Majka , Michael Phipps , Martin Purschke , Nikolai Smirnov

Isotopic composition measurements of singly charged cosmic rays (CR) provide essential insights into CR transport in the Galaxy. The Alpha Magnetic Spectrometer (AMS-02) can identify singly charged isotopes up to about 10 GeV/n. However,…

High Energy Astrophysical Phenomena · Physics 2024-04-25 Marta Borchiellini , Leandro Mano , Fernando Barão , Manuela Vecchi

The TORCH time-of-flight detector is designed to provide a 15 ps timing resolution for charged particles, resulting in $\pi$/$K$ particle identification up to 10 GeV/c momentum over a 10 m flight path. Cherenkov photons, produced in a…

TORCH is a time-of-flight detector designed to perform particle identification over the momentum range 2$-$10 GeV/c for a 10 m flight path. The detector exploits prompt Cherenkov light produced by charged particles traversing a quartz plate…

We are constructing a Ring Imaging Cherenkov detector (RICH) for the CLEO III upgrade for precision charged hadron identification. The RICH uses plane and sawtooth LiF crystals as radiators, MWPCs as photon detectors with TEA as the…

The TORCH time-of-flight detector will provide particle identification between 2-10 GeV/c momentum over a flight distance of 10 m, and is designed for large-area coverage, up to 30 m^2. A 15 ps time-of-flight resolution per incident…

The AMS detector, to be installed on the International Space Station, includes a Ring Imaging Cerenkov detector with two different radiators, silica aerogel (n=1.05) and sodium fluoride (n=1.334). This detector is designed to provide very…

Cherenkov radiation provides a valuable way to identify high energy particles in a wide momentum range, through the relation between the particle velocity and the Cherenkov angle. However, since the Cherenkov angle depends only on…

A fast trigger system is being designed as a potential upgrade to VERITAS, or as the basis for a future array of imaging atmospheric-Cherenkov telescopes such as AGIS. The scientific goal is a reduction of the energy threshold by a factor…

Instrumentation and Methods for Astrophysics · Physics 2009-08-04 M. Schroedter , J. Anderson , K. Byrum , G. Drake , C. Duke , J. Holder , A. Imran , A. Madhavan , F. Krennrich , A. Kreps , A. Smith