Related papers: Performance of the PrimEx Electromagnetic Calorime…
A preliminary design of the PEP-N electromagnetic calorimeter is given. The spatial,energy and time resolutions achievable using a KLOE type electromagnetic calorimeter are presented.
The resolution and the linearity of time measurements made with the CMS electromagnetic calorimeter are studied with samples of data from test beam electrons, cosmic rays, and beam-produced muons. The resulting time resolution measured by…
We have exposed seven full length production quality crystals of the electromagnetic calorimeter (ECAL) of the CMS detector to a 20 GeV/c proton beam at the CERN PS accelerator. The exposure was done at fluxes of 10**12 p/cm**2/h and 10**13…
We present two variants of a magnetic microcalorimeter with paramagnetic temperature sensors and integrated dc-SQUID readout for high-resolution X-ray emission spectroscopy. Each variant employs two overhanging gold absorbers with a…
Precision physics at future multi-TeV lepton colliders such as CLIC requires excellent jet energy resolution. The detectors need deep calorimeter systems to limit the energy leakage also for very highly energetic particles and jets. At the…
The SDHCAL technological prototype that has been completed in 2012 was exposed to beams of pions and electrons of different energies at the CERN SPS for a total time period of 5 weeks. The data has been analyzed within the CALICE…
The CASTOR calorimeter is a detector covering the very forward region of the CMS experiment at the LHC. It surrounds the beam pipe with 14 longitudinal modules each of which consisting of 16 azimuthal sectors and allows to reconstruct…
The next generation experiment in high energy particle physics will be International Linear Collider of electron and positron at the TeV scale. The experiment is aim to search the Higgs particle and to measure its properties. The physics…
We describe the testing of a prototype SiPM-on-tile iron-scintillator calorimeter at the Relativistic Heavy Ion Collider (RHIC) during its 200 GeV $pp$ run in 2024. The prototype, measuring $20 \times 20 \, \text{cm}^{2}$ and 24 radiation…
The Mu2e experiment at Fermilab searches for the charged-lepton flavour violating (CLFV) conversion of a negative muon into an electron in the field of an aluminum nucleus, with a distinctive signature of a mono-energetic electron of energy…
The Mu2e experiment at Fermilab searches for the neutrino-less conversion of a negative muon into an electron, with a distinctive signature of a mono-energetic electron with energy of 104.967 MeV. The calorimeter is made of two disks of…
An x-ray detector using a liquid-helium cooled large-area silicon PIN photodiode has been developed along with a tailor-made charge sensitive preamplifier whose first-stage JFET has been cooled. The operating temperature of the JFET has…
The CALICE Semi-Digital Hadron Calorimeter technological prototype completed in 2011 is a sampling calorimeter using Glass Resistive Plate Chamber (GRPC) detectors as the active medium. This technology is one of the two options proposed for…
Eight PbWO4 crystals produced for the electromagnetic calorimeter of the CMS experiment at LHC have been irradiated in a 20 GeV/c proton beam up to fluences of 5.4 E13 p/cm2. The damage recovery in these crystals, stored in the dark at room…
CMS calorimeter energy calibration was done in the full CMS simulated geometry for the pseudorapidity region eta = 0. The samples of single pion events were generated with a set of incident energies from 10 GeV to 3 TeV. The analysis of the…
A combination Time Projection Chamber-Cherenkov prototype detector has been developed as part of the Detector R&D Program for a future Electron Ion Collider. The prototype was tested at the Fermilab test beam facility to provide a proof of…
A Shashlyk calorimeter prototype for the KOPIO experiment has been constructed and experimentally tested. The energy resolution of about 4%/sqrt(E(GeV)) for 0.5-2.0 GeV/c positrons was obtained. Based on this results as well as on the…
We describe the details of a silicon-tungsten prototype electromagnetic calorimeter module and associated readout electronics. Detector performance for this prototype has been measured in test beam experiments at the CERN PS and SPS…
The particles produced at a potential Future Circular Collider with $\sqrt{s}$ = 100 TeV are of unprecented energies. In this document we present the hadronic shower containment and resolution parametrizations based on Geant4 simulations…
An important experiment for cosmic ray physics is going to be conducted with the colliding proton beams of the CERN LHC. The equivalent energy of the 14 TeV center of mass energy of the colliding proton beams in the LHC is 1017eV in the…