Related papers: Performance of the PrimEx Electromagnetic Calorime…
The prototype of the hadron calorimeter module consisting of 66 scintillator/lead layers with the 15x15 cm^2 cross section and 5 nuclear interaction lengths has been designed and produced for the zero degree calorimeter of the BM@N…
CMS calorimeter energy calibration was done in the full CMS simulated geometry for the pseudorapidity region eta = 0. The samples of single pion events were generated with a set of incident energies from 5 GeV to 3 TeV and for single…
The detailed information about electron response, electron energy resolution and e/h ratio as a function of incident energy E, impact point Z and incidence angle $\Theta$ of iron-scintillator hadron prototype calorimeter with longitudinal…
The GlueX experiment at Jefferson Laboratory aims to perform quantitative tests of non-perturbative QCD by studying the spectrum of light-quark mesons and baryons. A Detector of Internally Reflected Cherenkov light (DIRC) was installed to…
A hybrid dual-readout calorimeter concept, comprising both electromagnetic and hadronic sections, has recently been proposed to meet the performance requirements of experiments at future e$^{+}$e$^{-}$ colliders. The front compartment…
The EIC will deliver collisions of electrons with protons and nuclei at a wide variety of energies and at luminosities up to 1000 times higher than HERA. Precise measurement of both the scattered electron and the hadronic final state is…
New generation high-energy physics experiments demand high precision tracking and accurate measurements of a large number of particles produced in the collisions of lementary particles and heavy-ions. Silicon-tungsten (Si-W) calorimeters…
We have developed a custom amplifier board coupled to a large-format 16-channel Hamamatsu silicon photomultiplier device for use as the light sensor for the electromagnetic calorimeters in the Muon g-2 experiment at Fermilab. The…
The performance of the electromagnetic calorimeter of the ALICE experiment during operation in 2010-2018 at the Large Hadron Collider is presented. After a short introduction into the design, readout, and trigger capabilities of the…
A high granularity hadronic 1 m3 calorimeter prototype with semi-digital readout has been designed and built. This calorimeter has been made using stainless steel as absorber and Glass Resistive Plates Chambers (GRPC) as active medium, and…
In this study, we propose a novel fully active total absorption calorimeter with enhanced read out capabilities through fine splitting. The proposed calorimeter employs a sandwich structure composed of scintillator glasses and lead glasses,…
The AMoRE collaboration searches for neutrinoless double beta decay of $^{100}$Mo using molybdate scintillating crystals via low temperature thermal calorimetric detection. The early phases of the experiment, AMoRE-pilot and AMoRE-I, have…
We present the results of a test beam campaign on a capillary-tube fibre-based dual-readout calorimeter, designed for precise hadronic and electromagnetic energy measurements in future collider experiments. The calorimeter prototype…
A silicon-tungsten (Si-W) sampling calorimeter, consisting of 19 alternate layers of silicon pad detectors (individual pad area of 1~cm$^2$) and tungsten absorbers (each of one radiation length), has been constructed for measurement of…
A calorimeter was built to measure the heat from a porous capacitive working electrode connected in a three-electrode configuration. This makes it possible to detect differences between cathodic and anodic heat production. The…
EBEX was a long-duration balloon-borne experiment to measure the polarization of the cosmic microwave background. The experiment had three frequency bands centered at 150, 250, and 410 GHz and was the first to use a kilo-pixel array of…
In nuclear, particle and astroparticle physics experiments, calorimeters are used to measure the properties of particles with kinetic energies that range from a fraction of 1 eV to 10^20 eV or more. These properties are not necessarily…
High-resolution pionic-atom x-ray spectroscopy was performed with an x-ray spectrometer based on a 240-pixel array of superconducting transition-edge-sensor (TES) microcalorimeters at the piM1 beam line of the Paul Scherrer Institute.…
A lead scintillator sandwich sampling calorimeter has been installed in the HERA tunnel 105.6 m from the central ZEUS detector in the proton beam direction. It is designed to measure the energy and scattering angle of neutrons produced in…
The energy response of the ATLAS calorimeter is measured for single charged pions with transverse momentum in the range $10<p_\textrm{T}<300$ GeV. The measurement is performed using 139 $\textrm{fb}^{-1}$ of LHC proton-proton collision data…