English
Related papers

Related papers: Detection of radio frequency magnetic fields using…

200 papers

We propose a novel paradigm to vector magnetometry based on machine learning. Unlike conventional schemes where one measured signal explicitly connects to one parameter, here we encode the three-dimensional magnetic-field information in the…

Instrumentation and Detectors · Physics 2023-10-04 Xin Meng , Youwei Zhang , Xichang Zhang , Shenchao Jin , Tingran Wang , Liang Jiang , Liantuan Xiao , Suotang Jia , Yanhong Xiao

Electrically conductive objects can be detected using the principle of electromagnetic induction where a primary oscillating magnetic field induces eddy currents in the object, which in turn produce a secondary magnetic field that can be…

Applied Physics · Physics 2022-12-06 L. M. Rushton , T. Pyragius , A. Meraki , L. Elson , K. Jensen

We demonstrate electromagnetic induction imaging with an unshielded, portable radio-frequency atomic magnetometer scanning over the target object. This configuration satisfies standard requirements in typical applications, from security…

Atomic Physics · Physics 2021-07-28 Cameron Deans , Yuval Cohen , Han Yao , Benjamin Maddox , Antonio Vigilante , Ferruccio Renzoni

We present a method to measure the magnetic properties of monolayers and ultra-thin films of magnetic material. The method is based on low energy muon spin rotation and $\beta$-detected nuclear magnetic resonance measurements. A spin probe…

Mesoscale and Nanoscale Physics · Physics 2012-06-07 Z. Salman , S. J. Blundell

Optically pumped atomic magnetometers (OPMs) offer highly sensitive magnetic measurements using compact hardware, offering new possibilities for practical precision sensors. Double-resonance OPM operation is well suited to unshielded…

Cardiomagnetometry is a growing field of noninvasive medical diagnostics that has triggered a need for affordable high-sensitivity magnetometers. Optical pumping magnetometers are promising candidates satisfying that need since it was…

Medical Physics · Physics 2009-11-10 Georg Bison , Robert Wynands , Antoine Weis

We report on a microwave planar ring antenna specifically designed for optically-detected magnetic resonance (ODMR) of nitrogen-vacancy (NV) centers in diamond. It has the resonance frequency at around 2.87 GHz with the bandwidth of 400…

Mesoscale and Nanoscale Physics · Physics 2016-05-30 Kento Sasaki , Yasuaki Monnai , Soya Saijo , Ryushiro Fujita , Hideyuki Watanabe , Junko Ishi-Hayase , Kohei M. Itoh , Eisuke Abe

We have developed a technique in which Rb atomic response to weak magnetic field is high and an efficient rotation of linearly polarized laser beam results in efficient magnetometry. 85Rb isotope has been used for the magnetometry in an…

Atomic Physics · Physics 2011-01-21 S. M. Iftiquar

Optically pumped magnetometers are becoming a promising alternative to cryogenically-cooled superconducting magnetometers for detecting and imaging biomagnetic fields. Magnetic field detection is a completely non-invasive method, which…

SERF magnetometers based on dense ensembles of alkali-metal spins are precision quantum sensors that hold the record of measured and projected sensitivity to magnetic fields, in the $\mu\textrm{G}-\textrm{mG}$ range. At geomagnetic fields…

Quantum Physics · Physics 2025-05-29 Mark Dikopoltsev , Uriel Levy , Or Katz

Optically-pumped atomic magnetometers have previously been used in arrays to reject interference from far away sources and enable the sensitive detection of local sources of radio frequency (RF) signals, useful, for instance, in the…

Instrumentation and Detectors · Physics 2026-02-10 Ayse Marasli , Thomas Kornack , Casey Oware , Karen L. Sauer

Nitrogen-vacancy quantum defects in diamond offer a promising platform for magnetometry because of their remarkable optical and spin properties. In this Letter, we present a high-sensitivity and wide-bandwidth fiber-based quantum…

We report on an optical magnetometer enhanced by vacuum-squeezed light, employing an Mx magnetometer based on $^{87}$Rb vapor in a micrometer-scale cell (~100 $\mu$m). Using the well-established polarization self-rotation effect in a…

Atomic spin polarization of alkali atoms in the ground state can survive thousands of collisions with paraffin-coated cell walls. The resulting long spin-relaxation times achieved in evacuated, paraffin-coated cells enable precise…

Atomic Physics · Physics 2009-11-06 D. F. Jackson Kimball , L. R. Jacome , Srikanth Guttikonda , Eric J. Bahr , Lok Fai Chan

Weak measurement (WM) with state pre- and post-selection can amplify otherwise undetectable small signals and thus promise great potentials in precision measurements. Although frequency measurements offer the hitherto highest precision…

Atomic Physics · Physics 2018-12-10 Weizhi Qu , Jian Sun , Shenchao Jin , Liang Jiang , Jianming Wen , Yanhong Xiao

We study experimentally the fundamental limits of sensitivity of an atomic radio-frequency magnetometer. First we apply an optimal sequence of state preparation, evolution, and the back-action evading measurement to achieve a nearly…

Quantum Physics · Physics 2011-01-28 W. Wasilewski , K. Jensen , H. Krauter , J. J. Renema , M. V. Balabas , E. S. Polzik

The local magnetic field in a Penning-Malmberg trap is found by measuring the temperatures that result when electron plasmas are illuminated by microwaves pulses. Multiple heating resonances are observed as the pulse frequencies are swept.…

Plasma Physics · Physics 2020-03-18 E. D. Hunter , A. Christensen , J. Fajans , T. Friesen , E. Kur , J. S. Wurtele

We realise an intrinsic optically pumped magnetic gradiometer based on non-linear magneto-optical rotation. We show that our sensor can reach a gradiometric sensitivity of 18 $\text{fT}/\text{cm}/\sqrt{\text{Hz}}$ and can reject common mode…

We present a novel approach allowing an optically pumped magnetometer (OPM) to be operated within Earth's magnetic field as a vector magnetometer whose sensitive axis can be freely defined. This approach enables the measurement of any…

Instrumentation and Detectors · Physics 2024-08-20 Thomas Schönau , Theo Scholtes , Florian Wittkämper , Alexander Sekels , Stefan Hiebel , Gregor Oelsner , Ronny Stolz

Using standard nuclear magnetic resonance (NMR) technique and a well-fabricated sample, we have succeeded in directly observing local magnetic field generated by a micro-magnet Ni45Fe55 (the thickness of 400-nm) which was sputtered on an Al…

Mesoscale and Nanoscale Physics · Physics 2008-07-16 Shinji Watanabe , Susumu Sasaki , Shinya Sato , Naoki Isogai , Yoshinori Matsumoto