English
Related papers

Related papers: FIRST: Fast Iterative Reconstruction Software for …

200 papers

Patient motion during PET is inevitable. Its long acquisition time not only increases the motion and the associated artifacts but also the patient's discomfort, thus PET acceleration is desirable. However, accelerating PET acquisition will…

Image and Video Processing · Electrical Eng. & Systems 2023-02-15 Bo Zhou , Yu-Jung Tsai , Jiazhen Zhang , Xueqi Guo , Huidong Xie , Xiongchao Chen , Tianshun Miao , Yihuan Lu , James S. Duncan , Chi Liu

Traditional algorithms for compressive sensing recovery are computationally expensive and are ineffective at low measurement rates. In this work, we propose a data driven non-iterative algorithm to overcome the shortcomings of earlier…

Computer Vision and Pattern Recognition · Computer Science 2017-08-18 Suhas Lohit , Kuldeep Kulkarni , Ronan Kerviche , Pavan Turaga , Amit Ashok

Purpose: Neural network image reconstruction directly from measurement data is a relatively new field of research, that until now has been limited to producing small single-slice images (e.g., 1x128x128). This paper proposes a novel and…

Image and Video Processing · Electrical Eng. & Systems 2020-02-13 William Whiteley , Wing K. Luk , Jens Gregor

The foreseen CaLIPSO Positron Emission Tomography (PET) scanner is expected to yield simultaneously a fine image resolution, about 1 mm$^3$, and a high contrast. In this paper we present results of simulations for the full CaLIPSO PET…

In this work, we propose a new paradigm of iterative model-based reconstruction algorithms for providing real-time solution for zooming-in and refining a region of interest in medical and clinical tomographic images. This algorithmic…

Image and Video Processing · Electrical Eng. & Systems 2025-12-01 Junqi Tang , Guixian Xu , Jinglai Li

For collecting high-quality high-resolution (HR) MR image, we propose a novel image reconstruction network named IREM, which is trained on multiple low-resolution (LR) MR images and achieve an arbitrary up-sampling rate for HR image…

Image and Video Processing · Electrical Eng. & Systems 2021-06-30 Qing Wu , Yuwei Li , Lan Xu , Ruiming Feng , Hongjiang Wei , Qing Yang , Boliang Yu , Xiaozhao Liu , Jingyi Yu , Yuyao Zhang

Several methods have been proposed for large-scale 3D reconstruction from large, unorganized image collections. A large reconstruction problem is typically divided into multiple components which are reconstructed independently using…

Computer Vision and Pattern Recognition · Computer Science 2016-10-13 Rajvi Shah , Aditya Deshpande , P J Narayanan

In Robotics, especially in this era of autonomous driving, mapping is one key ability of a robot to be able to navigate through an environment, localize on it and analyze its traversability. To allow for real-time execution on constrained…

Robotics · Computer Science 2018-01-17 Enrico Piazza , Andrea Romanoni , Matteo Matteucci

This is a review paper on some of the physics, modeling, and iterative algorithms in proton computed tomography (pCT) image reconstruction. The primary challenge in pCT image reconstruction lies in the degraded spatial resolution resulting…

Medical Physics · Physics 2015-10-30 Scott Penfold , Yair Censor

Generalizable neural surface reconstruction has become a compelling technique to reconstruct from few images without per-scene optimization, where dense 3D feature volume has proven effective as a global representation of scenes. However,…

Computer Vision and Pattern Recognition · Computer Science 2025-07-09 Aoxiang Fan , Corentin Dumery , Nicolas Talabot , Hieu Le , Pascal Fua

The goal of this paper is to present a non-iterative and more importantly an extremely fast algorithm to reconstruct images from compressively sensed (CS) random measurements. To this end, we propose a novel convolutional neural network…

Computer Vision and Pattern Recognition · Computer Science 2016-03-09 Kuldeep Kulkarni , Suhas Lohit , Pavan Turaga , Ronan Kerviche , Amit Ashok

Photoacoustic Microscopy (PAM) images integrating the advantages of optical contrast and acoustic resolution have been widely used in brain studies. However, there exists a trade-off between scanning speed and image resolution. Compared…

Image and Video Processing · Electrical Eng. & Systems 2025-03-06 Kai Pan , Linyang Li , Li Lin , Pujin Cheng , Junyan Lyu , Lei Xi , Xiaoyin Tang

Fourier Ptychographic Microscopy (FPM) is a computational imaging technique that enables high-resolution imaging over a large field of view. However, its application in the biomedical field has been limited due to the long image…

Image and Video Processing · Electrical Eng. & Systems 2024-08-27 Ruiqing Sun , Delong Yang , Yiyan Su , Shaohui Zhang , Qun Hao

SPECT (Single-photon Emission Computerized Tomography) and PET (Positron Emission Tomography) are essential medical imaging tools, for which the sampling angle number, scan time should be chosen carefully to compromise between image quality…

Medical Physics · Physics 2015-06-16 Xiaolin Zhou , Minkai Yun , Xuexiang Cao , Shuangquan Liu , Lu Wang , Xianchao Huang , Long Wei

Over the past decade, reflection matrix microscopy (RMM) and advanced image reconstruction algorithms have emerged to address the fundamental imaging depth limitations of optical microscopy in thick biological tissues and complex media. In…

Optics · Physics 2024-07-03 Sungsam Kang , Seokchan Yoon , Wonshik Choi

Convolutional neural networks (CNNs) have recently achieved remarkable performance in positron emission tomography (PET) image reconstruction. In particular, CNN-based direct PET image reconstruction, which directly generates the…

Medical Physics · Physics 2024-10-28 Fumio Hashimoto , Kibo Ote

Reducing scan time in Positron Emission Tomography (PET) imaging while maintaining high-quality images is crucial for minimizing patient discomfort and radiation exposure. Due to the limited size of datasets and distribution discrepancy…

Image and Video Processing · Electrical Eng. & Systems 2024-07-11 Yumin Kim , Gayoon Choi , Seong Jae Hwang

Positron emission tomography (PET) is widely used in various clinical applications, including cancer diagnosis, heart disease and neuro disorders. The use of radioactive tracer in PET imaging raises concerns due to the risk of radiation…

Computer Vision and Pattern Recognition · Computer Science 2017-12-13 Junshen Xu , Enhao Gong , John Pauly , Greg Zaharchuk

Purpose: Optoacoustic tomography (OAT) is inherently a three-dimensional (3D) inverse problem. However, most studies of OAT image reconstruction still employ two-dimensional (2D) imaging models. One important reason is because 3D image…

Medical Physics · Physics 2013-04-09 Kun Wang , Chao Huang , Yu-Jiun Kao , Cheng-Ying Chou , Alexander A. Oraevsky , Mark A. Anastasio

Image reconstruction for positron emission tomography (PET) is challenging because of the ill-conditioned tomographic problem and low counting statistics. Kernel methods address this challenge by using kernel representation to incorporate…

Image and Video Processing · Electrical Eng. & Systems 2022-05-26 Siqi Li , Guobao Wang