Related papers: The BABAR Muon System Upgrade
Data from the first run of the BaBar detector at the PEP II accelerator are presented. Measurements of many rare B decay modes are now possible using the large data sets currently being collected by BaBar. An overview of analysis techniques…
CMS experiment will use Resistive Plate Chambers (RPCs) as dedicated muon trigger detectors. The first 24 RPCs for the barrel muon system of the CMS experiment have been assembled and tested. A brief description of the cosmic muon telescope…
The CMS experiment, located at the Large Hadron Collider (LHC) in CERN, has a redundant muon system composed by three different gaseous detector technologies: Cathode Strip Chambers (in the forward regions), Drift Tubes (in the central…
This paper reports the latest developmental efforts for a position-sensitive glass-based Resistive Plate Chamber (RPC) and a multi-channel Data AcQuisition (DAQ) system tailored for muon tracking in muography applications. The designed…
The high pseudorapidity ($\eta$) region of the Compact Muon Solenoid (CMS) muon system is covered by Cathode Strip Chambers only and lacks redundant coverage despite the fact that it is a challenging region for muons in terms of backgrounds…
The Muon Chamber (MuCh) is a sub-system of the Compressed Baryonic Matter (CBM) experiment for the detection of low-mass-vector mesons produced in high energy heavy-ion collisions at beam energies ranging from 2 AGeV to 11 AGeV and decaying…
A new type of resistive plate chamber (RPC) is under development using thin-film resistive electrodes based on diamond-like carbon (DLC). Planned to be put on the path of high-intensity low-momentum muon beam of the MEG II experiment, this…
An extensive system test of the ATLAS muon spectrometer has been performed in the H8 beam line at the CERN SPS during the last four years. This spectrometer will use pressurized Monitored Drift Tube (MDT) chambers and Cathode Strip Chambers…
Resistive Plate Chambers (RPCs) are essential active media of large-scale experiments as part of the muon systems and (semi-)digital hadron calorimeters. Among the several outstanding issues associated with the RPCs, the loss of efficiency…
We report on the behaviour of Resistive Plate Chambers (RPC) developed for muon detection in ultra-high energy cosmic ray (UHECR) experiments. The RPCs were developed for the MARTA project and were tested on field conditions. These RPCs…
The main results of the quality assurance tests performed on the Resistive Plate Chamber used by the ATLAS experiment at LHC as muon trigger chambers are reported and discussed. Since July 2004, about 270 RPC units has been certified at…
The contribution of Resistive Plate Chamber (RPC) to muon reconstruction in CMS has been studied on a sample of muons collected in proton-proton collisions at sqrt(s) = 7 TeV at the LHC in 2011. Muon reconstruction is performed using the…
We present recent results of an extensive aging test, performed at the CERN Gamma Irradiation Facility on two single--gap RPC prototypes, developed for the LHCb Muon System. With a method based on a model describing the behaviour of an RPC…
The muon spectrometer of the CMS (Compact Muon Solenoid) experiment at the Large Hadron Collider (LHC) is equipped with a redundant system made of Resistive Plate Chambers (RPCs) and Drift Tube (DT) chambers in the barrel, RPC and Cathode…
The phase-out of hydro-fluorocarbons, owing to their high Global Warming Power, affecting the main gas used in Resistive Plate Chambers (RPCs), tetrafluoroethane C$_2$H$_2$F$_4$, has increased operational difficulties on existing systems…
During the upcoming High Luminosity phase of the Large Hadron Collider (HL-LHC), the integrated luminosity of the accelerator will increase to 3000 fb$^{-1}$. The expected experimental conditions in that period in terms of background rates,…
Single gap (gas gap 2 mm) bakelite Resistive Plate Chamber (RPC) modules of various sizes from 10 cm \times 10 cm to 1 m \times 1 m have been fabricated, characterized and optimized for efficiency and time resolution. Thin layers of…
The muon spectrometer of the CMS (Compact Muon Solenoid) experiment at the Large Hadron Collider (LHC) is equipped with a redundant system made of Resistive Plate Chambers and Drift Tube in barrel and RPC and Cathode Strip Chamber in endcap…
The BABAR detector, which operates at the SLAC PEP-II asymmetric e^+e^- collider at energies near the Y(4S) resonance, started operation on the 26th of May 1999. We present the first study of sin2beta, with samples of B0 --> J/psi K0S and…
The muon detector of LHCb, which comprises 1368 multi-wire-proportional-chambers (MWPC) for a total area of 435 m2, is the largest instrument of its kind exposed to such a high-radiation environment. In nine years of operation, from 2010…