English
Related papers

Related papers: Design guide for electronics for resistive charge …

200 papers

The presence of critical resonances in microwave power amplifiers has a negative impact on its behavior and performance. These critical resonances are usually predicted from pole-zero stability simulations. In this paper, a different and…

Instrumentation and Detectors · Physics 2025-01-29 Juan-Mari Collantes , Nerea Otegi , Aitziber Anakabe , Libe Mori , Asier Barcenilla , Jose Manuel Gonzalez-Perez

A transimpedance amplifier has been designed for scanning tunneling microscopy (STM). The amplifier features low noise (limited by the Johnson noise of the 1 G{\Omega} feedback resistor at low input current and low frequencies), sufficient…

Instrumentation and Detectors · Physics 2020-07-02 Martin Štubian , Juraj Bobek , Martin Setvin , Ulrike Diebold , Michael Schmid

A thick gas electron multiplier is considered for radiation-hard detectors (hadron calorimeter). There was carried out technological and design study to optimize the element structure. The measurements results and the next plans are…

Instrumentation and Detectors · Physics 2009-09-30 V. Inshakov , V. Kryshkin , N. Kuzmin , V. Skvortsov , S. Sychkov , A. Sytin

The baseline energy-resolution performance for the current generation of large-mass, low-temperature calorimeters (utilizing TES and NTD sensor technologies) is $>2$ orders of magnitude worse than theoretical predictions. A detailed study…

Instrumentation and Methods for Astrophysics · Physics 2015-03-13 Matt Pyle , Enectali Figueroa-Feliciano , Bernard Sadoulet

A neutron counter designed for assay of radioactive materials has been adapted for beam experiments at TUNL. The cylindrical geometry and 60% maximum efficiency make it well suited for ($\gamma,n$) cross-section measurements near the…

Nuclear Experiment · Physics 2015-03-17 C. W. Arnold , T. B. Clegg , H. J Karwowski , G. C. Rich , J. R. Tompkins , C. R. Howell

Two-dimensional solid state gaseous detector for thermal and cold neutrons is created. The detector has active area of 128 x 128 $mm^2$, $^{10}B$ neutron converter, and gas chamber with thin windows. The resistive charge-division readout is…

Instrumentation and Detectors · Physics 2017-04-05 S Potashev , Yu Burmistrov , A Drachev , S Karaevsky , E Konobeevski , S Zuyev

We have developed and successfully used several innovative designs of detectors with solid photocathodes. The main advantage of these detectors is that rather high gains (>10E4) can be achieved in a single multiplication step. This is…

Instrumentation and Detectors · Physics 2009-11-07 P. Carlson , C. Iacobeaus , T. Francke , B. Lund-Jensen , L. Periale , V. Peskov , I. Rodionov

Detectors of terahertz radiation based on field-effect transistors (FETs) are among most promising candidates for low-noise passive signal rectification both in imaging systems and wireless communications. However, it was not realised so…

Mesoscale and Nanoscale Physics · Physics 2021-11-01 Aleksandr Shabanov , Maxim Moskotin , Vsevolod Belosevich , Yakov Matyushkin , Maxim Rybin , Georgy Fedorov , Dmitry Svintsov

Nanomechanical resonators having small mass, high resonance frequency and low damping rate are widely employed as mass detectors. We study the performances of such a detector when the resonator is driven into a region of nonlinear…

Quantum Physics · Physics 2009-11-13 Eyal Buks , Bernard Yurke

A conventional resonant detector is often subject to a trade-off between bandwidth and peak sensitivity that can be traced back to quantum Cramer-Rao Bound. Anomalous dispersion has been shown to improve it by signal amplification and is…

Quantum Physics · Physics 2020-12-03 Xiang Li , Maxim Goryachev , Yiqiu Ma , Michael E. Tobar , Chunnong Zhao , Rana X Adhikari , Yanbei Chen

Thermal neutron detector based on films of $^{10}$B$_4$C have been developed as an alternative to $^3$He detectors. In particular, The Multi-Grid detector concept is considered for future large area detectors for ESS and ILL instruments. An…

Recently we have proposed a new concept of a thermal neutron detector based on resistive plate chambers and 10B4C solid neutron converters, enabling to readout with high resolution in both the 3D position of neutron capture and the neutron…

Cryogenic rare event searches based on heat and light composite calorimeters have a common need for large area photon detectors with high quantum efficiency, good radiopurity and high sensitivity. By employing the Neganov-Trofimov-Luke…

Instrumentation and Detectors · Physics 2018-09-26 X. Defay , E. Mondragon , J. -C. Lanfranchi , A. Langenkamper , A. Munster , W. Potzel , S. Schonert , S. Wawoczny , M. Willers

A well-balanced detector with high sensitivity and low noise is presented in this paper. The two-stage amplification structure is used to increase electronic gain while keeping an effective bandwidth of about 70 MHz. In order to further…

Instrumentation and Detectors · Physics 2018-06-13 Qi-Ming Lu , Qi Shen , Yuan Cao , Sheng-Kai Liao , Cheng-Zhi Peng

The present article primarily focuses on the design of an ultra-low-noise amplifier specifically tailored for quantum applications. The circuit design places a significant emphasis on improving the noise figure, as quantum-associated…

Quantum Physics · Physics 2024-02-20 Ahmad Salmanogli , Vahid Sharif Sirat

Parametric amplifiers have become a workhorse in superconducting quantum computing, however research and development of these devices has been hampered by inconsistent, and sometimes misleading noise performance characterization…

Quantum Physics · Physics 2023-12-25 M. Malnou , T. F. Q. Larson , J. D. Teufel , F. Lecocq , J. Aumentado

Driven by the recent improvement in additive manufacturing technologies, we designed a detector that can be fully printed with a standard and commercial 3D printer. The main goals of this research concern the marginal design and…

The Neganov-Trofimov-Luke (NTL) effect is used by experiments based on cryogenic detectors to boost the sensitivity of light-sensitive devices down to a few optical photons. In this work we introduce a silicon light-detector technology that…

A switched-capacitor matrix multiplier is presented for approximate computing and machine learning applications. The multiply-and-accumulate operations perform discrete-time charge-domain signal processing using passive switches and 300 aF…

Emerging Technologies · Computer Science 2016-12-06 Edward H. Lee , S. Simon Wong

A photonic heat amplifier (PHA) designed for cryogenic operations is introduced and analyzed. This device comprises two variable-range-hopping reservoirs connected by lossless lines, which allow them to exchange heat through photonic modes.…

Mesoscale and Nanoscale Physics · Physics 2025-06-13 Matteo Pioldi , Giorgio De Simoni , Alessandro Braggio , Francesco Giazotto