Related papers: Distributions of positron-emitting nuclei in proto…
This article describes simulations of scattering of annihilation gamma quanta in a strip of plastic scintillator. Such strips constitute basic detection modules in a newly proposed Positron Emission Tomography which utilizes plastic…
High-energy photonuclear ($\gamma+A$) scattering in ultra-peripheral heavy-ion collisions provides a unique probe of nuclear structure. This Letter studies the dependence of $\gamma+A$ jet production in ultra-peripheral Pb+Pb collisions at…
In this study, by attempting to resolve the angular complication during the particle generation for the muon tomography applications in the GEANT4 simulations, we exhibit an unconventional methodology that is hinged on the direction…
A large acceptance scintillator detector with wavelength shifting optical fibre readout has been designed and built to detect the decay particles of $\eta$-nucleus bound system (the so-called $\eta$-mesic nuclei), namely, protons and pions.…
Several models for the simulation of photon elastic scattering are quantitatively evaluated with respect to a large collection of experimental data retrieved from the literature. They include models based on the form factor approximation,…
We have used the TOPAS Geant4-based package to create a parametric simulation of a new TOF-PET scanner design based on a low atomic number scintillator. TOPAS was extended to provide complete information on individual particle position,…
A comprehensive numerical investigation has been conducted on the angular distribution and spectrum of radiation emitted by 855 MeV electron and positron beams while traversing a 'quasi-mosaic' bent silicon (111) crystal. This interaction…
The measurement of the beta asymmetry parameter in nuclear beta decay is a potentially very sensitive tool to search for non V-A components in the charge-changing weak interaction. To reach the required precision (percent level) all effects…
Geant4 software is used to study 10 MeV photon beams and 100 MeV proton beams. Conclusions are drawn as to the advantages and disadvantages of each therapy, with some additional commentary on the secondary effects of radiation damage in…
Absolute differential cross sections for elastic $p^7$Be and $p^8$B small-angle scattering were measured in inverse kinematics at an energy of 0.7 GeV/u at GSI Darmstadt. The hydrogen-filled ionization chamber IKAR was used as an active…
Positron emission tomography (PET) is widely used to assess metabolic activity, but its application is limited by the availability of radiotracers. 18F-labeled fluorodeoxyglucose (18F-FDG) is the most commonly used tracer but shows limited…
Low energy protons (< 300 keV) can enter the field of view of X-ray space telescopes, scatter at small incident angles, and deposit energy on the detector, causing intense background flares at the focal plane or in the most extreme cases,…
We present a model for the distribution of the number of forward neutrons emitted in soft (minimum bias) and hard inelastic proton-nucleus ($pA$) scattering at the LHC. It is based on the Gribov-Glauber model for the distribution over the…
Proton therapy is a cancer treatment technique currently in growth worldwide. It offers advantages with respect to conventional X-ray and $\gamma$-ray radiotherapy, in particular, a better control of the dose deposition allowing to reach a…
In the evaluation of weak interacting massive particles (WIMPs) detection rates, the WIMP-nucleus cross section is commonly described by using form factors extracted from charge distributions. In this work, we use different proton and…
Passive Gamma Emission Tomography (PGET) is an IAEA-approved technique for verifying spent nuclear fuel assemblies prior to geological disposal. Reconstructing the emission and attenuation maps from PGET measurements is a nonlinear…
We present a nitrogen-targeting-Proton-Carbon-Alpha-Therapy method, abbreviated as Proton-CAT, which partially converts protons into carbon-12 and $\alpha$ particles through nuclear reactions between protons and nitrogen-15. Monte Carlo…
We present simulations of whole-body low-dose time-of-flight positron emission tomography (TOF-PET) based on the direct surface production [1] by 511 keV gamma rays of energetic electrons via the Photo-electric and Compton Effects,…
Purpose: To measure dispersion of a clinical proton therapy beam. Methods and Materials: The proton center at our institution uses a Hitachi PROBEAT V synchrotron that delivers beams with energies ranging from 70 to 230 MeV to five…
Soft X-ray emission from neutron stars affords powerful diagnostic tools for uncovering their surface and interior properties, as well as their geometric configurations. In the atmospheres of neutron stars, the presence of magnetic fields…