We describe a method aiming at increasing the dynamic range of X-ray detectors. Two X-ray exposures of an object are acquired at different dose levels and constitute the only input data. The values of the parameters which are needed to…
Gain calibration of x-ray area detectors is a challenge due to the inability to generate an x-ray flat field at the selected photon energy that the beamline operates at, which has a strong influence on the detector's gain behavior. A method…
Pixel detectors typically display pixel-to-pixel gain variation of a few percent which result in reduced spectroscopic performance. We have developed a calibration method which relies on cross-correlating histograms of many pixel pairs and…
Phase-retrieval from coded diffraction patterns (CDP) is important to X-ray crystallography, diffraction tomography and astronomical imaging, yet remains a hard, non-convex inverse problem. We show that CDP recovery can be reformulated…
Flat-panel cone-beam CT (CBCT) has been applied clinically in a number of high-resolution applications. Increasing geometric magnification can potentially improve resolution, but also increases blur due to an extended x-ray focal-spot. We…
Cone-beam CT (CBCT) is installed in the treatment room to facilitate online clinical applications, including image guidance in radiation and surgery. Half-fan and short-can are the commonly used modes in clinical applications to expand the…
Dual-energy imaging is a clinically well-established technique that offers several advantages over conventional X-ray imaging. By performing measurements with two distinct X-ray spectra, differences in energy-dependent attenuation are…
This study introduces an innovative application of Conditional Generative Adversarial Networks (C-GAN) integrated with Stacked Hourglass Networks (SHGN) aimed at enhancing image segmentation, particularly in the challenging environment of…
Background: Recently, the popularity of dual-layer flat-panel detector (DL-FPD) based dual-energy cone-beam CT (DE-CBCT) imaging has been increasing. However, the image quality of DE-CBCT remains constrained by the Compton scattered X-ray…
Dual-energy computed tomography (DECT) has been widely used to obtain quantitative elemental composition of imaged subjects for personalized and precise medical diagnosis. Compared with DECT leveraging advanced X-ray source and/or detector…
Computed Tomography (CT) is a medical imaging modality that can generate more informative 3D images than 2D X-rays. However, this advantage comes at the expense of more radiation exposure, higher costs, and longer acquisition time. Hence,…
X-ray images play a vital role in the intraoperative processes due to their high resolution and fast imaging speed and greatly promote the subsequent segmentation, registration and reconstruction. However, over-dosed X-rays superimpose…
LDCT has drawn major attention in the medical imaging field due to the potential health risks of CT-associated X-ray radiation to patients. Reducing the radiation dose, however, decreases the quality of the reconstructed images, which…
Industrial cone-beam X-ray computed tomography (CT) scans of additively manufactured components produce a 3D reconstruction from projection measurements acquired at multiple predetermined rotation angles of the component about a single…
X-ray microtomography is a powerful non-destructive technique allowing 3D virtual histology of resected human tissue. The achievable imaging field-of-view, is however limited by the fixed number of detector elements, enforcing the…
Diffractive lenses have recently been applied to the domain of multispectral imaging in the X-ray and UV regimes where they can achieve very high resolution as compared to reflective and refractive optics. Conventionally, spectral…
We propose a method to achieve the geometric calibration of cone-beam imaging and delivery systems in radiation therapy; our approach applies to devices where an X-ray source and a flat-panel detector, facing each other, move in circular…
Cone-beam computed tomography (CBCT) offers advantages over conventional fan-beam CT in that it requires a shorter time and less exposure to obtain images. CBCT has found a wide variety of applications in patient positioning for…
In clinical diagnosis, diagnostic images that are obtained from the scanning devices serve as preliminary evidence for further investigation in the process of delivering quality healthcare. However, often the medical image may contain fault…
The aim of this research is to reconstruct the 3D X-ray refractive index gradient maps by the proposed vector Radon transform and its inverse, assuming that the small-angle deviation condition is met. Theoretical analyses show that the…