Related papers: Electric and Photoelectric Gates for ion backflow …
A new concept for a hybrid structure gaseous detector module with ion backflow suppression for the time projection chamber in a future circular collider is presented. It is a hybrid structure cascaded Gas Electron Multiplier (GEM) with a…
Gas Electron Multipliers have undergone a very consistent development since their invention in 1997. Their production procedures have been tuned in such a way that nowadays it is possible to produce foils with areas of the order of the…
In gaseous tracking detectors with a large gaseous volume multiple layers of Gas Electron Multipliers (GEM) can be used to block positive ions from flowing back into the active volume, which is detrimental to the tracking performance. We…
Micro-Pattern Gas Detectors (MPGDs) are extensively employed in modern high-energy and nuclear Physics experiments because of their excellent spatial resolution, high rate capability, and operational stability. Among these, the Gas Electron…
A systematic study is performed to measure the ion backflow fraction of the GEM detectors. The effects of different voltage configurations and Ar/CO_2 gas mixtures, in ratios of 70:30, 80:20 and 90:10, on positive ion fraction are…
We study the feedback of positive ions in triple and quadruple Gas Electron Multiplier (GEM) detectors. The effects of GEM hole diameter, detector gain, applied voltages, number of GEMs and other parameters on ion feedback are investigated…
The operation of gas detectors is often limited by secondary effects, originating from avalanche-induced photons and ions. Ion backflow is one of the effects limiting the operation of a gas detector at high flux, by giving rise to space…
Gated wires are widely used in Time Projection Chamber (TPC) to avoid ion back-flow (IBF) in the drift volume. The anode wires can provide stable gain at high voltage with a long lifetime. However, switching on and off the gated grid (GG)…
We present overlapping top gate electrodes for the formation of gate defined lateral junctions in semiconducting layers as an alternative to the back gate/top gate combination and to the split gate configuration. The optical lithography…
Gaseous detectors are used in both low energy and high energy physics experiments. The present day gaseous detectors, i.e., the Micro-Pattern gaseous detectors (MPGD) are more efficient and fast. Gas Electron multiplier (GEM) is quite well…
We present a Photon-Assisted Cascaded Electron Multipliers (PACEM) which has a potential for ion back-flow blocking in gaseous radiation detectors: the avalanche from a first multiplication stage propagates to the successive one via its…
Time Projection Chamber (TPC) has been chosen as the main tracking system in several high-flux and high repetition rate experiments. These include on-going experiments such as ALICE and future experiments such as PANDA at FAIR and ILC.…
Secondary discharges, which consist of the breakdown of a gap near a GEM foil upon a primary discharge across that GEM, are studied in this work. Their main characteristics are the occurrence a few $10\,\mu \textrm{s}$ after the primary,…
A novel concept for ion blocking in gas-avalanche detectors was developed, comprising cascaded micro-hole electron multipliers with patterned electrodes for ion defocusing. This leads to ion blocking at the 10^{-4} level, in DC mode, in…
Gas electron Multipliers (GEM) are a new generation of gaseous avalanche devices in the Micro Patterned Gaseous Detector category. GEMs are widely used in both nuclear and high energy experiments as well as in medical science. Several…
Time Projection Chamber (TPC) is one of the main tracking systems for many current and future collider experiments at RHIC and LHC. It has a capability to measure the space points of charged tracks for good momentum resolution as well as…
Micro-Pattern Gas Detectors (MPGDs) represent a category of gaseous ionization detectors that utilize microelectronics. They feature a remarkably small distance between the high potential difference anode and cathode electrodes and are…
We report on the progress in the study of cascaded GEM and GEM/MHSP gas avalanche photomultipliers operating at atmospheric pressure, with CsI and bialkali photocathodes. They have single-photon sensitivity, ns time resolution and good…
Optical readout of Gas Electron Multipliers (GEM) provides very interesting performances and has been proposed for different applications in particle physics. In particular, thanks to its good efficiency in the keV energy range, it is being…
A new concept is presented for the reduction of ion back-flow in GEM-based cascaded gaseous electron multipliers, by incorporating Micro-Hole & Strip Plate (MHSP) elements operating in reversed-bias mode (R-MHSP). About an order of…