English
Related papers

Related papers: START: low-noise efficient trigger for cosmic muon…

200 papers

Further progress in building high-granular large-scale systems based on Scintillation Tiles with MRS APD light readout (START) became possible thanks to the creation of an improved version of MRS APD. The cost of the system may now be…

START, a high-efficiency and low-noise scintillation detector for ionizing particles, was developed for the purpose of creating a high-granular system for triggering cosmic muons. Scintillation light in START is detected by MRS APDs…

A Cosmic Ray Test Facility (CRTF) is the first large-scale implementation of a scintillation triggering system based on a new scintillation technique known as START. In START, the scintillation light is collected and transported by WLS…

Instrumentation and Detectors · Physics 2009-11-13 A. Akindinov , V. Golovin , E. Grigoriev , Yu. Grishuk , S. Kuleshov , D. Malkevich , A. Martemiyanov , A. Nedosekin , M. Ryabinin , K. Voloshin

The NUCLEUS experiment aims to measure coherent elastic neutrino nucleus scattering of reactor anti-neutrinos using cryogenic calorimeters. Operating at an overburden of 3 m.w.e., muon-induced backgrounds are expected to be one of the…

Research on a large-area, cost-effective Muon Telescope Detector has been carried out for RHIC and for next generation detectors at future QCD Lab. We utilize state-of-the-art multi-gap resistive plate chambers with large modules and long…

Nuclear Experiment · Physics 2019-08-13 Lijuan Ruan

The CMS Level-1 trigger was used to select cosmic ray muons and LHC beam events during data-taking runs in 2008, and to estimate the level of detector noise. This paper describes the trigger components used, the algorithms that were…

Instrumentation and Detectors · Physics 2012-08-27 CMS Collaboration

The possibility to build a SiPM-readout muon detector (SiRO), using plastic scintillators with optical fibers as sensitive volume and readout by SiPM photo-diodes, is investigated. SiRO shall be used for tracking cosmic muons based on…

The NO$\nu$A collaboration has constructed a 14,000 ton, fine-grained, low-Z, total absorption tracking calorimeter at an off-axis angle to an upgraded NuMI neutrino beam. This detector, with its excellent granularity and energy resolution…

High Energy Physics - Experiment · Physics 2015-11-03 R. Mina , E. Culbertson , M. J. Frank , R. C. Group , A. Norman , I. Oksuzian

Photomultiplier tube (PMT) and Silicon Photo Multiplier (SiPM) are often used for detecting small number of photons or very weak radiations. A light guide usually connects these photodetectors to the test space. In this article, we…

Instrumentation and Detectors · Physics 2023-11-28 Gholamreza Fardipour Raki , Mohsen Khakzad , Shehu AbdusSalam

Experiments like ATLAS at the HL-LHC or detectors at future hadron colliders need muon detectors with excellent momentum resolution up to the TeV scale both at the trigger and offline reconstruction levels. This requires muon tracking…

We propose a large-area, cost-effective Muon Telescope Detector (MTD) for the Solenoidal Tracker at RHIC (STAR) at mid-rapidity and for the next generation of detectors at a possible electron-ion collider. We utilize Multi-gap Resistive…

Measurements of cosmogenic particles at various locations and altitudes are becoming increasingly important in view of worldwide interests in rare signals for search of new physics. In this work, we report measurement of muon zenith angle…

Instrumentation and Detectors · Physics 2022-07-20 Hariom Sogarwal , Prashant Shukla

Experiments such as mu2e (FNAL, USA) and COMET (KEK, Japan), seeking the direct muon-to-electron conversion as part of the study of Charged Leptons Flavor Violation processes, should have a extremely high, up-to 99.99\%, efficiency muon…

Instrumentation and Detectors · Physics 2023-10-04 A. Artikov , V. Baranov , A. Boikov , D. Chokheli , Yu. I. Davydov , V. Glagolev , A. Simonenko , Z. Tsamalaidze , I. Vasilyev , I. Zimin

We measured signals of low amplitudes originating from cosmic rays, using two rectangular-block scintillation detectors at various positions. The signals were analyzed by a slightly modified signal analyzer from project 'MuonLab', designed…

Instrumentation and Detectors · Physics 2022-11-10 Jan Oldenziel

Elementary particle physics is a fascinating field of modern physics investigating the basic constituents of matter and their interactions. In the experiments large accelerators and very sophisticated detector systems are usually used.…

Physics Education · Physics 2018-05-09 D. Bosnar , Z. Matić , I. Friščić , P. Žugec , H. Janči

Prototype scintilator+WLS strips with SiPM readout for muon system at future colliders were tested for light yield, time resolution and position resolution. Depending on the configuration, light yield of up to 36 photoelectrons per muon per…

Instrumentation and Detectors · Physics 2015-10-13 Dmitri Denisov , Valery Evdokimov , Strahinja Lukić

This work presents the design and performance study of compact strips of plastic scintillator with WLS-fiber readout in a dimension of 0.1 * 0.02 * 2 m3, which evaluates as a candidate for cosmic-ray muon detector for JUNO-TAO. The strips…

Instrumentation and Detectors · Physics 2022-10-11 Min Li , Zhimin Wang , Caimei Liu , Peizhi Lu , Guang Luo , Yuen-Keung Hor , Jinchang Liu , Changgen Yang

In this paper, we present development of a portable cosmic muon tracker tailored for both on-site measurements of cosmic muon flux as well as for outreach activities. The tracker comprises of two 70 mm x 70 mm plastic scintillators,…

Instrumentation and Detectors · Physics 2026-03-02 Yuvaraj Elangovan , Shashwat Kakkad , B. Satyanarayana

The performance of the Local Trigger based on the drift-tube system of the CMS experiment has been studied using muons from cosmic ray events collected during the commissioning of the detector in 2008. The properties of the system are…

Instrumentation and Detectors · Physics 2012-08-27 The CMS Collaboration

The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of…

Instrumentation and Detectors · Physics 2012-08-27 CMS Collaboration
‹ Prev 1 2 3 10 Next ›