Related papers: High-energy proton induced damage study of scintil…
To investigate the 1.6 GeV high-energy proton beam detector utilized in the CSNS Phase-II upgrade project, a plastic scintillator detector presents a viable option due to its superior radiation hardness. This study investigates the effects…
We investigate the influence of oxygen annealing on the room temperature optical and scintillation properties of CaWO$_4$ single crystals that are being produced for direct Dark Matter search experiments. The applied annealing procedure…
The $3 \times 1 \times 1$ m$^3$ demonstrator is a dual phase liquid argon time projection chamber that has recorded cosmic rays events in 2017 at CERN. The light signal in these detectors is crucial to provide precise timing capabilities.…
Zinc molybdate (ZnMoO4) single crystals were grown for the first time by the Czochralski method and their luminescence was measured under X ray excitation in the temperature range 85-400 K. Properties of ZnMoO4 crystal as cryogenic low…
We report the performances of a 0.51 kg CdWO4 scintillating bolometer to be used for future Double Beta Decay Experiments. The simultaneous read-out of the heat and the scintillation light allows to discriminate between different…
The hadronic shower longitudinal and lateral leakages and its effect on the pion response and energy resolution of iron-scintillator barrel hadron prototype calorimeter with longitudinal tile configuration with a thickness of 9.4 nuclear…
Fast hadrons have been observed to cause a cumulative damage in Lead Tungstate and LYSO crystals. The underlying mechanism has been proven to be the creation of fission tracks, which act as scattering centres, thus reducing the light…
The Mu2e calorimeter is composed by 1400 un-doped CsI crystals coupled to large area UV extended Silicon Photomultipliers arranged in two annular disks. This calorimeter has to provide precise information on energy, timing and position. It…
The scintillation decay time constant of a ZnWO$_4$ crystal irradiated with $\alpha$-particles from $^{241}$Am was precisely investigated, and was found to depend on the incident direction of the $\alpha$-particles on the crystal. The…
The energy resolution of a highly granular 1 m3 analogue scintillator-steel hadronic calorimeter is studied using charged pions with energies from 10 GeV to 80 GeV at the CERN SPS. The energy resolution for single hadrons is determined to…
Calibration of the forward CMS hadron calorimeters in situ by the LHC beam is proposed. Simulations show that bent crystal channeling technique is feasible at the LHC, and report the experience of IHEP Protvino in bending 70 GeV protons by…
We study the optical properties of glass exposed to ionizing radiation, as it occurs in the space environment. 24 glass types have been considered, both space qualified and not space qualified. 72 samples (3 for each glass type) have been…
In this paper, we report on the study of the optical properties of YAG:Ce and GGG:Ce garnet crystals after irradiation in a 660~MeV proton beam with a fluence up to 8.9$\times$10$^{14}$ protons/cm$^2$. We found that the transparency of both…
The RD52 (DREAM) collaboration is performing R\&D on dual readout calorimetry techniques with the aim of improving hadronic energy resolution for future high energy physics experiments. The simultaneous detection of Cherenkov and…
Electromagnetic calorimeters used in high-energy physics and astrophysics rely heavily on high-Z inorganic scintillators, such as lead tungstate (PbWO4 or PWO). The crystalline structure and lattice orientation of inorganic scintillators…
In the context of particle therapy monitoring, we are developing a gamma-ray detector to determine the ion range in vivo from the measurement of particle time-of-flight. For this application, a beam monitor capable to tag in time the…
The multi-TeV energy region of the cosmic-ray spectra has been recently explored by direct detection experiments that used calorimetric techniques to measure the energy of the cosmic particles. Interesting spectral features have been…
A large cylindrical cadmium molybdate crystal with natural isotopic abundance has been used to fabricate a scintillating bolometer. The measurement was performed above ground at milli-Kelvin temperature, with simultaneous readout of the…
The resistivity of polycrystalline chemical vapor deposition diamond sensors is studied in samples exposed to fluences relevant to the environment of the High Luminosity Large Hadron Collider. We measure the leakage current for a range of…
We report on the initial results of an experiment to determine the effects of proton radiation damage on an X-ray hybrid CMOS detector (HCD). The device was irradiated at the Edwards Accelerator Lab at Ohio University with 8 MeV protons, up…