Related papers: Development of the Charge Particle Detector Based …
To prevent excessive radiation damage to its Silicon Vertex Tracker, the BaBar experiment at SLAC uses a radiation monitoring and protection system that triggers a beam abort whenever radiation levels are anomalously high. The existing…
The development of Chemical Vapour Deposition (CVD) diamond detectors requests for novel signal amplifiers, capable to match the superb signal-to-noise ratio and timing response of these detectors. Existing amplifiers are still far away…
The electronic spins of the nitrogen-vacancy centers (NV centers) in Chemical-Vapor-Deposition (CVD) grown diamonds form ideal probes of magnetic fields and temperature, as well as promising qu-bits for quantum information processing.…
A 0.93 gram $1{\times}1{\times}0.4$ cm$^3$ SuperCDMS silicon HVeV detector operated at 30 mK was illuminated by 1.91 eV photons using a room temperature pulsed laser coupled to the cryostat via fiber optic. The detector's response under a…
The demands on optical components to tolerate high radiation dose and manipulate hard x-ray beams that can fit the experiment requirements, are constantly increasing due to the advancements in the available x-ray sources. Here we have…
The sharp optical resonances of NV- centers in diamond at cryogenic temperatures offer powerful new capabilities for material characterization, but extracting the most detailed information typically requires careful calibration of…
The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector based on a MM detector operating in a two-stage amplification mode and a Cherenkov radiator. Prototypes equipped with cesium iodide (CsI) photocathodes have shown…
Superconducting nanowire single photon detectors (SNSPDs) are fabricated directly on diamond substrates and their optical and electrical properties are characterized. Dark count performance and photon count rates are measured at varying…
In beam test experiments have been carried out for particle identification using digital pulse shape analysis in a 500~$\mu$m thick Neutron Transmutation Doped (nTD) silicon detector with an indigenously developed FPGA based 12 bit…
We have developed radiation detectors using the new synthetic diamonds. The diamond detector has an advantage for observations of "low/medium" energy gamma rays as a Compton telescope. The primary advantage of the diamond detector can…
This paper reports on the fabrication and characterization of a high purity monocrystalline diamond detector with buried electrodes realized by the selective damage induced by a focused 6 MeV carbon ion beam scanned over a pattern defined…
We report detector characteristics and background measurements from two prototype imaging CZT detectors flown on a scientific balloon payload in May 2001. The detectors are both platinum-contact 10mm x 10mm x 5mm CZT crystals, each with a 4…
Diamond thin films were growth using Tequila as precursor by Pulsed Liquid Injection Chemical Vapor Deposition (PLI-CVD) onto both silicon (100) and stainless steel 304 at 850 C. The diamond films were characterized by Scanning Electron…
Thin film detectors which incorporate semiconductor materials other than silicon have the potential to build upon their unique material properties and offer advantages such as faster response times, operation at room temperature, and…
We are developing gaseous photon detectors for Cherenkov imaging applications in the experiments at the future Electron Ion Collider. CsI, converting photons in the far ultraviolet range, is, so far, the only photoconverter compatible with…
Liquid gas was used to produce DLC films on Cu, Al and steel substrates by DC plasma technique. The absorption in IR reflectance indicates, grown films are DLC. By deconvolution of room temperature UV-visible spectra of the films grown at…
Recent approaches to develop infrared photodetectors characterized by high sensitivities, broadband spectral coverage, easy integration with silicon electronics and low cost have been based on hybrid structures of transition metal…
This article introduces a design of a Low Noise Amplifier (LNA), for the field of diamond particle detectors. This amplifier is described from simulation to measurements, which include pulses from {\alpha} particles detection. In hadron…
At the n\_TOF experiment at CERN a dedicated single-crystal chemical vapor deposition (sCVD) Diamond Mosaic-Detector has been developed for (n,$\alpha$) cross-section measurements. The detector, characterized by an excellent time and energy…