Optical readout of large Time Projection Chambers (TPCs) with multiple Gas Electron Multipliers (GEMs) amplification stages has shown to provide very interesting performances for high energy particle tracking. Proposed applications for…

An array of DEPFET pixels is one of several concepts to implement an active pixel sensor. Similar to PNCCD and SDD detectors, the typically 0.45 mm thick silicon sensor is fully depleted by the principle of sideward depletion. They have…

Instrumentation and Methods for Astrophysics · Physics 2023-04-05 Norbert Meidinger , Johannes Müller-Seidlitz

Muon imaging technology is an innovative imaging technique that can be applied in volcano imaging, heavy nuclear material detection, and archaeological research. The Micromegas detector is a promising choice for muon imaging due to its high…

Instrumentation and Detectors · Physics 2024-10-28 Ting Wang , Yu Wang , Zhihang Yao , Yulin Liu , Changqing Feng , Zhiyong Zhang , Shubin Liu

Many modern video processing pipelines rely on edge-aware (EA) filtering methods. However, recent high-quality methods are challenging to run in real-time on embedded hardware due to their computational load. To this end, we propose an…

Image and Video Processing · Electrical Eng. & Systems 2017-11-16 Manuel Eggimann , Christelle Gloor , Florian Scheidegger , Lukas Cavigelli , Michael Schaffner , Aljosa Smolic , Luca Benini

A semiconductor tracker for muon scattering tomography is presented. The tracker contains silicon strip sensors with an $80\,\mu$m pitch, precision mechanics and integrated cooling. The electronic readout of the sensors is performed by a…

Instrumentation and Detectors · Physics 2018-10-30 F. Keizer , A. Gorbatch , M. A. Parker , C. Steer , S. A. Wotton

We have developed a dedicated front-end-electronics board for a high-pressure xenon gas time projection chamber for a neutrinoless double-beta decay search. The ionization signal is readout by detecting electroluminescence photons with…

Instrumentation and Detectors · Physics 2020-09-17 K. Z. Nakamura , S. Ban , A. K. Ichikawa , M. Ikeno , K. D. Nakamura , T. Nakaya , S. Obara , S. Tanaka , T. Uchida , M. Yoshida

A high-performance time-of-flight (TOF) MRPC wall is being built for the CBM experiment at FAIR for charged hadron identification. The detector control system for the TOF system will be based on EPICS. All components like power supplies for…

Instrumentation and Detectors · Physics 2021-02-03 S. Dong , G. M. Huang , J. Frühauf , P. -A. Loizeau , I. Deppner , N. Herrmann , D. Wang

The Data Quality Monitoring (DQM) of the Compact Muon Solenoid (CMS) silicon tracking detectors (Tracker) at the Large Hadron Collider (LHC) at CERN is a software based system designed to monitor the detector and reconstruction performance,…

Instrumentation and Detectors · Physics 2019-08-13 V. Adler

The LHCb Outer Tracker is a straw drift detector with a modular design and a total of 53760 readout channels distributed over a sensitive area of 12 double layers of 6x5 m2 each. The main electronics readout requirement is the precise (0.5…

Instrumentation and Detectors · Physics 2007-11-28 Eduard Simioni

A front end ASIC has been designed to equip the {\mu}TPC prototype developed for the MIMAC project, which requires 3D reconstruction of low energy particle tracks in order to perform directional detection of galactic Dark Matter. Each ASIC…

Instrumentation and Methods for Astrophysics · Physics 2011-11-22 J. P. Richer , O. Bourrion , G. Bosson , O. Guillaudin , F. Mayet , D. Santos

The small-strip Thin Gap Chamber (sTGC) will be used for both triggering and precision tracking purposes in the upgrade of the ATLAS forward muon spectrometer. Both sTGC pad and strip detectors are readout by a Trigger Data Serializer (TDS)…

Instrumentation and Detectors · Physics 2018-02-14 Jinhong Wang , Liang Guan , J. W. Chapman , Bing Zhou , Junjie Zhu

We outline the development of the readout software for the Prime-Cam and Mod-Cam instruments on the CCAT Fred Young Submillimeter Telescope (FYST), primecam_readout. The instruments feature lumped-element kinetic inductance detector (LEKID)…

The SALSA chip is a future readout ASIC foreseen for the MPGD detectors, developed in the framework of the EIC collider project, to equip the MPGD trackers of the EPIC experiment. It is designed to be versatile, to be adapted to other…

Maintaining the required performance of the CMS electromagnetic calorimeter (ECAL) barrel at the High-Luminosity Large Hadron Collider (HL-LHC) requires the replacement of the entire on-detector electronics. 12240 new very front end (VFE)…

Instrumentation and Detectors · Physics 2023-11-06 W. Lustermann , D. Abadjiev , G. Dissertori , M. Dejardin , T. Gadek , L. T. Martin , K. Stachon

The Large Hadron Collider (LHC) at CERN will undergo an upgrade in order to increase its luminosity to $7.5 \times 10^{34}$ cm$^{-2}$s$^{-1}$. The increased luminosity during this High-Luminosity running phase (HL-LHC), starting around…

Instrumentation and Detectors · Physics 2023-09-04 The Tracker Group of the CMS Collaboration

The Skipper CCD-in-CMOS Parallel Read-Out Circuit V2 (SPROCKET2) is designed to enable high frame rate readout of Skipper CCD-in-CMOS image sensors. The SPROCKET2 pixel is fabricated in a 65 nm CMOS process and occupies a 60$\mu$m $\times$…

Instrumentation and Detectors · Physics 2024-06-24 Adam Quinn , Farah Fahim , Davide Braga

In MicroPattern Gas Detectors (MPGD) when the pixel size is below 100 micron and the number of pixels is large (above 1000) it is virtually impossible to use the conventional PCB read-out approach to bring the signal charge from the…

Instrumentation and Detectors · Physics 2015-06-26 R. Bellazzini , F. Angelini , L. Baldini , F. Bitti , A. Brez , L. Latronico , M. M. Massai , M. Minuti , N. Omodei , M. Razzano , C. Sgro , G. Spandre , E. Costa , P. Soffitta

The search for a compatible application of memristor-CMOS logic gates has remained elusive, as the data density benefits are offset by slow switching speeds and resistive dissipation. Active microdisplays typically prioritize pixel density…

Emerging Technologies · Computer Science 2021-04-22 Xiaoyuan Wang , Zhiru Wu , Pengfei Zhou , Herbert H. C. Iu , Jason K. Eshraghian , Sung Mo Kang

The high instantaneous luminosities expected following the upgrade of the Large Hadron Collider (LHC) to the High Luminosity LHC (HL-LHC) pose major experimental challenges for the CMS experiment. A central component to allow efficient…