Related papers: Photosensitive Gaseous Detectors for Cryogenic Tem…
A number of critical active and passive components of optical links have been tested at 77 K or lower temperatures, demonstrating potential development of optical links operating inside the liquid argon time projection chamber (LArTPC)…
The phase-out of hydro-fluorocarbons, owing to their high Global Warming Power, affecting the main gas used in Resistive Plate Chambers (RPCs), tetrafluoroethane C$_2$H$_2$F$_4$, has increased operational difficulties on existing systems…
Thanks to intrinsically short electronic relaxation on the ps time scale, III-V semiconductor unipolar devices are ideal candidates for ultrahigh-speed operation at mid-infrared frequencies. In this work, antenna-coupled, GaAs-based multi…
Liquid argon time projection chambers (TPC) are widely used in neutrino oscillation and dark matter experiments. Detection of scintillation light in liquid argon TPC's is challenging because of its short wavelength, in the VUV range, and…
The ALETHEIA project aims to search for low-mass dark matter using liquid helium (LHe)-filled time projection chambers (TPCs). While liquid argon and liquid xenon TPCs have been extensively employed in the field of direct dark matter…
A large-area Multi-Pixel Photon Counter (MPPC) sensitive to vacuum ultra violet (VUV) light has been developed for the liquid xenon (LXe) scintillation detector of the MEG II experiment. The LXe detector is designed to detect the 52.8\,MeV…
Room temperature operation is mandatory for any optoelectronics technology which aims to provide low-cost compact systems for widespread applications. In recent years, an important technological effort in this direction has been made in…
In this paper we present the cryogenic functionality of the components of data links for the Liquid Argon Time Projection Chamber (LArTPC), a potential far site detector technology of the Long-Baseline Neutrino Experiment (LBNE). We have…
We review latest progress in gaseous photomultipliers (GPM) combining solid photocathodes and various types of novel electron multipliers. Cascaded gaseous electron multipliers (GEM) coated with CsI photocathodes can efficiently replace…
Large Resistive Plate Chamber systems have their roots in High Energy Physics experiments at the European Organization for Nuclear Research: ATLAS, CMS and ALICE, where hundreds of square meters of both trigger and timing RPCs have been…
The Hamamatsu R11410 photomultiplier, a tube of 3" diameter and with a very low intrinsic radioactivity, is an interesting light sensor candidate for future experiments using liquid xenon (LXe) as target for direct dark matter searches. We…
We summarize the development of visible-sensitive gaseous photomultipliers, combining a semitransparent bi-alkali photocathode with a state-of-the-art cascaded electron multiplier. The latter has high photoelectron collection efficiency and…
Two-dimensional solid state gaseous detector for thermal and cold neutrons is created. The detector has active area of 128 x 128 $mm^2$, $^{10}B$ neutron converter, and gas chamber with thin windows. The resistive charge-division readout is…
Cryogenic detectors have a long history of success in the field of rare event searches. In particular scintillating calorimeters are very suitable detectors for this task since they provide particle discrimination: the simultaneous…
Terahertz (THz) radiation has uses from security to medicine; however, sensitive room-temperature detection of THz is notoriously difficult. The hot-electron photothermoelectric effect in graphene is a promising detection mechanism:…
Frequency-selective or even frequency-tunable Terahertz (THz) photodevices are critical components for many technological applications that require nanoscale manipulation, control and confinement of light. Within this context, gate-tunable…
The last years have seen the first cryogenic detectors to be proposed for usage on balloon-borne missions. In such missions, the instrument will be exposed to the high radiation environment of the upper atmosphere. This radiation can induce…
Ultrathin microscale resistive thermometers are of key value to many applications. Here we have fabricated a laser machined 50 ${\mu}$m wide and 50 nm thick serpentine Pt thin film sensor capable of sensing temperatures up to 650 ${^\circ}$…
Photosensitive gaseous detectors with a simple photoelectron multiplication mechanism as resistive plate chambers are expected to offer both large photo coverage and excellent time resolution while keeping costs low. We have developed a…
Liquid xenon time projection chambers offer a homogeneous detection medium with excellent intrinsic energy resolution, fast scintillation, and true three-dimensional position sensitivity, making them an attractive alternative to…