Related papers: Monte Carlo study of a luminosity detector for the…
LumiCal will be the luminosity calorimeter for the proposed International Large Detector of the International Linear Collider (ILC). The ILC physics program requires the integrated luminosity to be measured with a relative precision on the…
The International Linear Collider (ILC) is a proposed electron-positron collider with a center-of-mass energy of 500~GeV, and a peak luminosity of $2 \cdot 10^{34}~\mathrm{cm}^{-2}\mathrm{s}^{-1}$. The ILC will complement the Large Hadron…
Based on a paper published in 2019 by the FCAL Collaboration, this talk is giving an update of the Collaboration's effort to design prototype of highly compact calorimeter to instrument the very forward region of a detector at future…
We describe another detectora designed for the International Linear Collider based on several tested instrumentation innovations in order to achieve the necessary experi- mental goal of a detecter that is 2-to-10 times better than the…
Two special calorimeters are foreseen for the instrumentation of the very forward region of the ILC detector, a luminometer designed to measure the rate of low angle Bhabha scattering events with a precision better than 10-3 and a low polar…
Luminosity monitoring at $e^+e^-$ colliders is investigated using SANC Monte Carlo event generator ReneSANCe and integrator MCSANC for simulation of Bhabha scattering at low angles. Results are presented for center-of-mass energies of the Z…
High energy longitudinal electron polarimetry will be based on Compton scattering for the International Linear Collider. An unobtrusive measurement has to include a magnet chicane setup serving as a spectrometer. Current proposals make use…
The CALICE Collaboration is carrying out research and development into calorimetry for a detector at the International Linear Collider (ILC). CALICE is investigating a range of technologies for both electromagnetic and hadronic calorimetry.…
The International Large Detector (ILD) is a concept for a detector at the International Linear Collider, ILC. The ILC will collide electrons and positrons at energies of initially 500 GeV, upgradeable to 1 TeV. The ILC has an ambitious…
The FCAL collaboration is preparing large scale prototypes of special calorimeters to be used in the very forward region at a future linear electron positron collider for a precise and fast luminosity measurement and beam-tuning. These…
High precision physics at future colliders requires unprecedented highly granular calorimeters for the application of the Particle Flow (PF) algorithm. The physical proof of concept was given in the previous campaign of beam tests of physic…
In order to measure integrated luminosity with a required precision of $10^{-4}$ at the $Z^0$ pole, proposed CEPC $e^{+}e^{-}$ collider requires a luminometer, a specially designed calorimeter placed in the very forward region to identify…
Detectors at future e+e- collider need special calorimeters in the very forward region for a fast estimate and precise measurement of the luminosity, to improve the hermeticity and mask the central tracking detectors from backscattered…
The Compact Linear Collider (CLIC) is a concept for a future $e^{+}e^{-}$ linear collider with a center-of-mass energy of up to 3 TeV. The design of a CLIC experiment is driven by the requirements related to the physics goals, as well as by…
The International Linear Collider (ILC) is the next large scale project in accelerator particle physics. Colliding electrons with positrons at energies from 0.3 TeV up to about 1 TeV, the ILC is expected to provide the accuracy needed to…
The International Large Detector (ILD) is a proposed detector for the International Linear Collider (ILC). It has been designed to achieve an excellent jet energy resolution by using Particle Flow Algorithms (PFA), which rely on the ability…
Measurement of the integrated luminosity at the International Linear Collider (ILC) will be accomplished by counting the rate of small angle Bhabha scattering events. The physics requirements for ILC set the constraint on the relative…
Purpose: Luminosity measurement at the Circular Electron-Positron Collider (CEPC) is required to achieve 10^-4 precision when operating at the center-of-mass energy of the Z-pole. Approximately 10^12 Z-bosons will be collected to refine…
The 4th Concept detector presently being designed for the International Linear Collider introduces several innovations in order to achieve the necessary experimental goal of a detecter that is 2-to-10 times better than the already excellent…
The CALICE analog HCAL is a highly granular calorimeter, proposed for the International Linear Collider. It is based on scintillator tiles, read out by silicon photomultipliers (SiPMs). The effects of gaps between the calorimeter tiles, as…