Related papers: Proposal for Cherenkov Time of Flight Technique wi…
Time of Flight methods have been rapidly developed and used in many experiments recently for determination of particle direction, identification of particles and energy resolutions. This paper describes a method of time-mark determination…
This paper presents results that take a critical step toward proving 10 ps timing resolution's feasibility for particle identification in the TOPSiDE detector concept for the Electron-Ion Collider. Measurements of LGADs with a thickness of…
We first briefly describe the history and motivation behind Cherenkov and scintillation light detection. We then discuss the instrumentation needed to detect these photons as it applies to both photodetectors and readout electronics. One of…
Since the early days of experimental particle physics photomultipliers (PMTs) have played an important role in the detector design. Thanks to their capability of fast photon counting, PMTs are extensively used in the new-generation of…
The Imaging Atmospheric Cherenkov technique allows to detect very high energy gamma rays from few tens of GeV to hundreds of TeV using ground-based instrumentation. At these energies a gamma ray generates a shower of secondary particles…
Next-generation air-shower detectors, such as the Global Cosmic Ray Observatory (GCOS) and the Probing Extreme PeVatron Sources (PEPS) experiment, are considering water-Cherenkov detectors as a base design. A key factor in improving the…
It is shown that the timing capabilities of the LHCb detector operated during the LHC Run 2 can be used to identify light ion particles with momenta of a few GeV/$c$. This is achieved by estimating the particle time of flight through a…
UHE particle detection using the lunar Cherenkov technique aims to detect nanosecond pulses of Cherenkov emission which are produced during UHE cosmic ray and neutrino interactions in the Moon's regolith. These pulses will reach Earth-based…
Fast timing detectors are an essential element in the experimental setup for time-of-flight (ToF) mass measurements of unstable nuclei. We have upgraded the scintillator detectors used in experiments at the National Superconducting…
The Cherenkov Telescope Array is a next generation ground-based gamma-ray observatory de- signed to detect photons in the 20 GeV to 300 TeV energy range. With a sensitivity improvement of up to one order of magnitude on the entire energy…
The potential of photon detectors to achieve precise timing information is of increasing importance in many domains, PET and CT scanners in medical imaging and particle physics detectors, amongst others. The goal to increase by an order of…
This paper presents a method to identify electrons using the Cherenkov light emitted when a charged particle travels in air and photons are detected with a Silicon PhotoMultiplier (SiPM). The analysis is based on a photon-counting approach…
The Major Atmospheric Gamma-ray Imaging Cherenkov (MAGIC) Telescope collaboration is constructing a large Cherenkov telescope (17 m diameter) for the exploration of the gamma-ray energy regime above 10 GeV with high sensitivity. One of the…
In this work, a part of the Research and Development effort of the PICOSEC detector is presented. The PICOSEC detector is a novel gas-filled detector, based on the Micromegas detector, which has been developed by the RD-51 PICOSEC…
In order to fully exploit the physics potential of the ILC, it will be necessary to measure (and control) beam parameters to a permille level precision. In case of the beam polarisation, this can only be achieved with dedicated high energy…
A system based on commercially available items, such as a laser diode, emitting in the visible range $\sim 400$ nm,and multimode fiber patches, fused fiber splitters and optical switches may be assembled,for time calibration of…
A large area ring-imaging Cherenkov detector has been designed to provide clean hadron identification capability in the momentum range from 3 GeV/c up to 8 GeV/c for the CLAS12 experiments at the upgraded 12 GeV continuous electron beam…
NectarCAM is a Cherenkov camera designed to detect gamma rays with energies between 80 GeV and 50 TeV. It will equip nine medium-sized telescopes (MSTs) of the Cherenkov Telescope Array Observatory. NectarCAM consists of 1855 pixels…
In this work, we report on the timing performances of the Time-Of-Flight (TOF) apparatus of the FRACAS large acceptance mass spectrometer designed to measure the fragmentation cross sections of a $^{12}$C beam in hadrontherapy. The TOF…
Between early 1997 and late 2002, the HEGRA collaboration operated a stereoscopic system of 4 (later 5) imaging atmospheric Cherenkov telescopes. In this paper we present the calibration schemes which were developed for the system, and…