Related papers: Tests of a Roman Pot Prototype for the TOTEM Exper…
The ATLAS experiment at the LHC is building several detector systems for forward physics studies and to determine the luminosity. The main forward systems consist of a Cerenkov detector called LUCID, a Zero Degree Calorimeter (ZDC) and…
Active pixel sensors based on the High-Voltage CMOS technology are being investigated as a viable option for the future pixel tracker of the ATLAS experiment at the High-Luminosity LHC. This paper reports on the testbeam measurements…
We describe the design of a Thomson scattering (TS) diagnostic to be used on the SMall Aspect Ratio Tokamak (SMART). SMART is a spherical tokamak being commissioned in Spain that aims to explore positive triangularity (PT) and negative…
We describe a physics program at the Relativistic Heavy Ion Collider (RHIC) with tagged forward protons. The program started with the proton-proton elastic scattering experiment (PP2PP), for which a set of Roman Pot stations was build. The…
We have built a RICH detector prototype consisting of a liquid C6F14 radiator and six triple Thick Gaseous Electron Multipliers (TGEMs), each of them having an active area of 10x10 cm2. One triple TGEM has been placed behind the liquid…
We describe a setup which will allow extend the physics reach of the STAR detector at RHIC to include the measurement of very forward protons. Tagging on very forward protons, detected by the Roman Pots at RHIC energies, selects processes,…
The CDF Forward Detector upgrade project was designed to enhance the capabilities for diffractive physics at the Tevatron. It consists of a Roman Pot spectrometer to detect leading antiprotons, a set of counters near and around the…
Experiments at the future Electron Ion Collider require excellent hadron identification in a broad momentum range, in harsh conditions. A RICH capable to fulfill the PID requirements of the EIC could use MPGD-based photon detectors with…
The tracking system of the CMS experiment, currently under construction at the Large Hadron Collider (LHC) at CERN (Geneva, Switzerland), will include a silicon pixel detector providing three spacial measurements in its final configuration…
The ALICE Collaboration is proposing a completely new apparatus, ALICE~3, for the LHC Runs~5 and beyond. In this context, a key subsystem for high-energy charged particle identification will be a proximity-focusing ring-imaging Cherenkov…
The Very Forward Proton Spectrometer (VFPS) of the H1 experiment at HERA is collecting data since 2005. The fiber detectors in the Roman pots located at 218 and 222m downstream from the H1 interaction point, tag and measure diffractively…
We describe the details of a silicon-tungsten prototype electromagnetic calorimeter module and associated readout electronics. Detector performance for this prototype has been measured in test beam experiments at the CERN PS and SPS…
A prototype neutron detector has been created through modification to a commercial non-volatile flash memory device. Studies are being performed to modify this prototype into a purpose-built device with greater performance and…
At the Tevatron, the total p_bar-p cross-section has been measured by CDF at 546 GeV and 1.8 TeV, and by E710/E811 at 1.8 TeV. The two results at 1.8 TeV disagree by 2.6 standard deviations, introducing big uncertainties into extrapolations…
In this talk we present a selection of forward physics results recently obtained with the run-1 and run-2 LHC data by the CMS, LHCf and TOTEM experiments. The status of the very forward LHC proton spectrometer, CT-PPS, is discussed:…
We describe the current status of the design and development of a Thomson X-ray polarimeter suitable for a small satellite mission. Currently we are considering two detector geometries, one using rectangular detectors placed on four sides…
During 2014 the second experimental area EAR2 was completed at the n-TOF neutron beam facility at CERN. As the neutrons are produced via spallation, by means of a high-intensity 20 GeV pulsed proton beam impinging on a thick target, the…
To expedite the commissioning process of the proton therapy system at Samsung Medical Center (SMC), we have developed a Monte Carlo simulation model of the proton therapy nozzles using TOPAS. At SMC proton therapy center, we have two gantry…
The TOTEM experiment at the LHC is dedicated to the measurement of the total pp cross section and to the study of elastic scattering and of diffractive dissociation processes. TOTEM is here presented with a general overview on the main…
When testing and calibrating particle detectors in a test beam, accurate tracking information independent of the detector being tested is extremely useful during the offline analysis of the data. A general-purpose Silicon Beam Tracker (SBT)…