Related papers: The Cleo Rich Detector
The Ring-Imaging Cherenkov (RICH) detectors at LHCb have an intrinsic time resolution of better than 10 ps owing to the prompt Cherenkov radiation and focusing mirrors optics. While only spatial information has been used in the experiment…
A large RICH detector is used in NA62 to suppress the muon contamination in the charged pion sample by a factor of 100 in the momentum range between 15 and 35 GeV/c. Cherenkov light is collected by 1952 photomultipliers placed at the…
In this work, we present a novel compact particle identification (PID) detector concept based on Silicon Photomultipliers (SiPMs) optimized to perform combined Ring-Imaging Cherenkov (RICH) and Time-of-Flight (TOF) measurements using a…
Ring Imaging Cherenkov (RICH) detectors are a key component of particle identification systems in many particle, nuclear and astroparticle physics experiments. Their ultimate performance depends not only on detector design and hardware…
The Alpha Magnetic Spectrometer (AMS) to be installed on the International Space Station (ISS) will measure charged cosmic ray spectra of elements up to iron, in the rigidity range from 1 GV to 1 TV, for at least three years. AMS is a large…
A proximity focusing ring imaging Cherenkov detector using aerogel as the radiator has been studied for an upgrade of the Belle detector at the KEK-B-factory. We constructed a prototype Cherenkov counter using a 4 x 4 array of 64-channel…
Imaging Cherenkov detectors form the backbone of particle identification (PID) at the future Electron Ion Collider (EIC). Currently all the designs for the first EIC detector proposal use a dual Ring Imaging CHerenkov (dRICH) detector in…
The CLEO detector will undergo major improvements in conjunction with a high luminosity upgrade of the CESR electron positron collider, that should increase the luminosity of this machine by a factor of 10. The most innovative feature of…
A novel photon detector, the Silicon Photomultiplier (SiPM), has been tested in proximity focusing Ring Imaging Cherenkov (RICH) counters that were exposed to cosmic-ray particles in Ljubljana, and a 2 GeV electron beam at the KEK research…
The ALICE Collaboration is proposing a completely new apparatus, ALICE~3, for the LHC Runs~5 and beyond. In this context, a key subsystem for high-energy charged particle identification will be a proximity-focusing ring-imaging Cherenkov…
The AMS detector, to be installed on the International Space Station, includes a Ring Imaging Cerenkov detector with two different radiators, silica aerogel (n=1.05) and sodium fluoride (n=1.334). This detector is designed to provide very…
Cherenkov radiation provides a valuable way to identify high energy particles in a wide momentum range, through the relation between the particle velocity and the Cherenkov angle. However, since the Cherenkov angle depends only on…
The HERA-B RICH uses a radiation path length of 2.8 m in C_4F_10 gas and a large 24 square meters spherical mirror for imaging Cherenkov rings. The photon detector consists of 2240 Hamamatsu multi-anode photomultipliers with about 27000…
The AMS spectrometer will be installed on the International Space Station at the end of 2003. Among other improvements over the first version of the instrument, a ring imaging Cherenkov detector (RICH) will be added which latter should open…
The LHCb detector will be upgraded to make more efficient use of the available luminosity at the LHC in Run III and extend its potential for discovery. The Ring Imaging Cherenkov detectors are key components of the LHCb detector for…
A prototype detector is being developed which combines the functions of a Time Projection Chamber for charged particle tracking and a Cherenkov detector for particle identification. The TPC consists of a 10x10x10 cm3 drift volume where the…
An algorithm for identifying rings in Ring Imaging Cherenkov (RICH) detectors is described. The algorithm is necessarily Bayesian and makes use of a Metropolis-Hastings Markov chain Monte Carlo sampler to locate the rings. In particular,…
A ring imaging Cherenkov counter, to be read out by four 100-channel PMTs, is a key element of the BRAHMS experiment. We report here the most recent results obtained tested at the BNL AGS using several radiator gases, including the heavy…
In the forward end-cap of the Belle II spectrometer, particle identification is provided by a proximity focusing RICH detector with an aerogel radiator (ARICH). The ARICH's primary function is to effectively distinguish between pions and…
The performance of the ring-imaging Cherenkov detectors at the LHCb experiment is determined during the LHC Run 2 period between 2015 and 2018. The stability of the Cherenkov angle resolution and number of detected photons with time and…