Related papers: Position resolution and particle identification wi…
A module of the ATLAS electromagnetic barrel liquid argon calorimeter was exposed to the CERN electron test-beam at the H8 beam line upgraded for precision momentum measurement. The available energies of the electron beam ranged from 10 to…
The performance of prototypes for the ALICE electromagnetic sampling calorimeter has been studied in test beam measurements at FNAL and CERN. A $4\times4$ array of final design modules showed an energy resolution of about 11%…
We study the photon detection efficiency and position resolution of the electromagnetic calorimeter (EMC) of the BESIII experiment. The control sample of the initial-state-radiation (ISR) process of $e^+e^-\rightarrow \gamma \mu^+\mu^-$ is…
We study the photon detection efficiency and position resolution of the electromagnetic calorimeter (EMC) of the BESIII detector. The control samples of the initial-state-radiation (ISR) process of $e^+e^-\rightarrow \gamma \mu^+\mu^-$ at…
Three spare modules of the ATLAS Tile Calorimeter were exposed to test beams from the Super Proton Synchrotron accelerator at CERN in 2017. The measurements of the energy response and resolution of the detector to positive pions and kaons…
The understanding of the reconstruction and calibration of electrons and photons is one of the key steps at the start-up of data-taking with ATLAS at the LHC (Large Hadron Collider). The calorimeter cells are electronically calibrated…
A new method for calibrating the hadron response of a segmented calorimeter is developed and successfully applied to beam test data. It is based on a principal component analysis of energy deposits in the calorimeter layers, exploiting…
A new method for calibrating the hadron response of a segmented calorimeter is developed. It is based on a principal component analysis of the calorimeter layer energy deposits, exploiting longitudinal shower development information to…
The energy response of the ATLAS calorimeter is measured for single charged pions with transverse momentum in the range $10<p_\textrm{T}<300$ GeV. The measurement is performed using 139 $\textrm{fb}^{-1}$ of LHC proton-proton collision data…
This paper presents the electron and photon energy calibration achieved with the ATLAS detector using about 25 fb$^{-1}$ of LHC proton--proton collision data taken at centre-of-mass energies of $\sqrt{s}$ = 7 and 8 TeV. The reconstruction…
We report on the simulation results for the angular resolution of an electromagnetic (EM) sampling calorimeter with photons in the range of 100~MeV to 2~GeV. The simulation model of the EM calorimeter consists of alternating layers of a…
The fine-sampling electromagnetic calorimeter prototype has been experimentally tested using the 1-19 GeV/c tagged beams of negatively charged particles at the U70 accelerator at IHEP, Protvino. The energy resolution measured by electrons…
The energy calibration and resolution of the electromagnetic calorimeter (ECAL) of the CMS detector have been determined using proton-proton collision data from LHC operation in 2010 and 2011 at a centre-of-mass energy of sqrt(s)=7 TeV with…
During summer 2004, a testbeam for the ATLAS experiment was performed at CERN. A full slice of the ATLAS detector was tested with the final version of the acquisition electronics. In the talk presented at Calor06 conference, the ATLAS…
A full azimuthal phi-wedge of the ATLAS liquid argon end-cap calorimeter has been exposed to beams of electrons, muons and pions in the energy range 6 GeV <= E <= 200 GeV at the CERN SPS. The angular region studied corresponds to the ATLAS…
The intrinsic performance of the ATLAS barrel and extended barrel calorimeters for the measurement of charged pions is presented. Pion energy scans (E = 20, 50, 200, 400 and 1000 GeV) at two pseudo-rapidity points ($\eta$ = 0.3 and 1.3) and…
A prototype Silicon-Tungsten electromagnetic calorimeter (ECAL) for an International Linear Collider (ILC) detector was installed and tested during summer and autumn 2006 at CERN. The detector had 6480 silicon pads of dimension 1x1 cm^2.…
The Alpha Magnetic Spectrometer (AMS) is a high-precision particle detector onboard the International Space Station containing six different subdetectors. The Transition Radiation Detector and Electromagnetic Calorimeter (ECAL) are used to…
This paper presents the electron and photon energy calibration obtained with the ATLAS detector using 140 fb$^{-1}$ of LHC proton-proton collision data recorded at $\sqrt{s}=13$ TeV between 2015 and 2018. Methods for the measurement of…
We present the electron/pion identification performance measured with prototypes for ALICE TRD. Measured spectra of energy deposit of pions and electrons as well as their average values are presented and compared to calculations. Various…