English
Related papers

Related papers: GEM operation in helium and neon at low temperatur…

200 papers

The paper presents a simplified formula to determine an electron temperature, Te(He I), for planetary nebulae (PNe) using the He I 7281/6678 line flux ratio. In our previous studies of Te(He I) (Zhang et al. 2005), we used the He I line…

Astrophysics · Physics 2007-05-23 Y. Zhang , R. H. Rubin , X. -W. Liu

Multi-channel wire gas electron multipliers (MWGEM) with gaps between the electrodes of 1 and 3mm were investigated. The chamber of the MWGEM was filled with pure commercial neon gas at pressure of 0.4 or 1.0 bar and irradiated by…

Instrumentation and Detectors · Physics 2010-05-11 B. M. Ovchinnikov , V. V. Parusov , Yu. B. Ovchinnikov

Presented here are first tests of a Gaseous Photomultiplier based on a cascade of Thick GEM structures intended for gamma-ray position reconstruction in liquid Argon. The detector has a MgF$_2$ window, transparent to VUV light, and a CsI…

Instrumentation and Detectors · Physics 2015-09-02 B. Lopez Paredes , C. D. R. Azevedo , S. Paganis , A. L. M. Silva , N. J. C. Spooner , J. F. C. A. Veloso

The Large Electron Multipliers (LEMs) are key components of double phase liquid argon TPCs. The drifting charges after being extracted from the liquid are amplified in the LEM positioned half a centimeter above the liquid in pure argon…

Instrumentation and Detectors · Physics 2015-06-23 C. Cantini , L. Epprecht , A. Gendotti , S. Horikawa , L. Periale , S. Murphy , G. Natterer , C. Regenfus , F. Resnati , F. Sergiampietri , A. Rubbia , T. Viant , S. Wu

The new beam profile measurement for the Antiproton Decelerator (AD) at CERN is based on a single Gas Electron Multiplier (GEM) with a 2D readout structure. This detector is very light, ~0.4% X_0, as required by the low energy of the…

Instrumentation and Detectors · Physics 2012-08-31 Serge Duarte Pinto , Philippe Carrière , Jens Spanggaard , Gerard Tranquille

New ternary Mg-Ni-Mn intermetallics have been successfully synthesized by High Energy Ball Milling (HEBM) and have been studied as possible materials for efficient hydrogen storage applications. The microstructures of the as-cast and milled…

At NISER-IoP detector laboratory an initiative is taken to build and test Gas Electron Multiplier (GEM) detectors for ALICE experiment. The optimisation of the gas flow rate and the long-term stability test of the GEM detector are…

Operation results are presented of a UV-sensitive gaseous photomultiplier (GPM) coupled through a MgF2 window to a liquid-xenon scintillator. It consisted of a reflective CsI photocathode deposited on top of a THick Gaseous Electron…

The new beam profile measurement for the Antiproton Decelerator (AD) at CERN is based on a single Gas Electron Multiplier (GEM) with a 2D readout structure. This detector is very light (~0.4% X0), and measures horizontal and vertical…

Instrumentation and Detectors · Physics 2012-03-20 Serge Duarte Pinto , Rhodri Jones , Leszek Ropelewski , Jens Spanggaard , Gerard Tranquille

Systematic studies on the gain and the energy resolution have been carried out varying the voltage across the GEM foils for both single mask and double mask triple GEM detector prototypes. Variation of the gain and the energy resolution…

Instrumentation and Detectors · Physics 2016-06-22 S. Biswas , D. J. Schmidt , A. Abuhoza , U. Frankenfeld , C. Garabatos , J. Hehner , V. Kleipa , T. Morhardt , C. J. Schmidt , H. R. Schmidt , J. Wiechula

We describe a method for scalable synthesis of epoxy composites with graphene and few-layer graphene fillers, and report on the electromagnetic interference (EMI) shielding and thermal properties of such composites at elevated temperatures.…

The realization of semiconductor structures with stable excitons at room temperature is crucial for the development of excitonics and polaritonics. Quantum confinement has commonly been employed for enhancing excitonic effects in…

Gas detector are very light instrument used in high energy physics to measure the particle properties: position and momentum. Through high electric field is possible to use the Gas Electron Multiplier (GEM) technology to detect the charged…

We have used the He I discontinuities at 3421A to determine the electron temperatures, designated Te(He I), for a sample of five Galactic planetary nebulae (PNe). We compared Te(He I) with the electron temperatures derived from the hydrogen…

Solar and Stellar Astrophysics · Physics 2011-02-11 Y. Zhang , H. -B. Yuan , C. -T. Hua , X. -W. Liu , J. Nakashima , S. Kwok

The operating principle and performances of the Multi-layer Thick Gaseous Electron Multiplier (M-THGEM) is presented. The M-THGEM is a novel hole-type gaseous electron multiplier produced by multi-layer printed circuit board technology; it…

Instrumentation and Detectors · Physics 2016-06-24 M. Cortesi , S. Rost , W. Mittig , Y. Ayyad Limonge , D. Bazin , J. Yurkon , A. Stolz

We have developed the gas electron multiplier (GEM) using polytetrafluoroethylene (PTFE) insulator substrate (PTFE-GEM). Carbonization on insulator layer by discharges shorts the GEM electrodes, causing permanent breakdown. Since PTFE is…

Instrumentation and Detectors · Physics 2014-03-27 M. Wakabayashi , K. Komiya , T. Tamagawa , Y. Takeuchi , K. Aoki , A. Taketani , H. Hamagaki

Electronic and magnetic properties of Ga$_{1-x}$Mn$_{x}$As, obtained from first-principles calculations employing the hybrid HSE06 functional, are presented for $x=6.25\%$ and $12.5\%$ under pressures ranging from 0 to 15 GPa. In agreement…

Materials Science · Physics 2015-05-27 N. Gonzalez Szwacki , Jacek A. Majewski , T. Dietl

Most attention to improving vacuum thermionic energy conversion device (TEC) technology has been on improving electron emission with little attention to collector optimization. A model was developed to characterize the output…

General Physics · Physics 2014-09-26 Joshua Ryan Smith

We report on the first results of the MACHe3 (MAtrix of Cells of Helium 3) prototype experiment concerning the measurement of low energy conversion electrons at ultra-low temperature. For the first time, the feasibility of the detection of…

Astrophysics · Physics 2011-07-19 E. Moulin , C. Winkelmann , J. F. Macias-Perez , Yu. M. Bunkov , H. Godfrin , D. Santos

We studied a novel cooling method, in which $^3$He and $^4$He are mixed at the $^4$He crystallization pressure at temperatures below $0.5\,\mathrm{mK}$. We describe the experimental setup in detail, and present an analysis of its…

Other Condensed Matter · Physics 2020-04-22 T. S. Riekki , A. P. Sebedash , J. T. Tuoriniemi