English
Related papers

Related papers: GEM operation in helium and neon at low temperatur…

200 papers

Study of the stability of gain and energy resolution for a triple GEM detector has been performed under continuous radiation of X-ray with high rate, using premixed gas of Argon and CO$_2$ in 70/30 ratio and conventional NIM electronics. A…

Instrumentation and Detectors · Physics 2018-04-10 S. Roy , S. Rudra , S. Shaw , R. P. Adak , S. Biswas , S. Das , S. K. Ghosh , S. K. Prasad , S. Raha

Gas Electron Multiplier (GEM) detector, one of the advanced members of the Micro Pattern Gas Detector (MPGD) group, is widely used in High Energy Physics (HEP) experiments. The high rate handling capability and spatial resolution make it a…

Instrumentation and Detectors · Physics 2023-05-17 S. Chatterjee , A. Sen , R. Paul , S. Sahai , S. Das , S. Biswas

In view of a possible application as a charge-particle track readout for an Active Target Time Projection Chamber (AT-TPC), the operating properties of THick Gaseous Electron Multipliers (THGEM) in pure low-pressure Helium were…

Instrumentation and Detectors · Physics 2015-06-23 Marco Cortesi , John Yurkon , Andreas Stolz

A comprehensive study, supported by systematic measurements and numerical computations, of the intrinsic limits of multi-GEM detectors when exposed to very high particle fluxes or operated at very large gains is presented. The observed…

The properties of thick GEM-like (TGEM) gaseous electron multipliers, operated at 1-740 Torr are presented. They are made of a G-10 plate, perforated with millimeter-scale diameter holes. In single-multiplier elements, effective gains of…

Instrumentation and Detectors · Physics 2015-06-26 R. Chechik , A. Breskin , C. Shalem , D. Moermann

A study has been carried out to evaluate the performance stability of Gas Electron Multiplier (GEM) chamber prototypes in the laboratory using $^{55}$Fe radiation source with Argon and CO$_2$ gas mixture. This research focuses on the…

Instrumentation and Detectors · Physics 2026-04-10 S. Mandal , S. Gope , S. Das , S. Biswas

The long-term stability in terms of gain and energy resolution of a prototype triple Gas Electron Multiplier (GEM) detector has been investigated with high rate X-ray irradiation. Premixed Ar/CO2 (80:20) and (90:10) gases have been used for…

Instrumentation and Detectors · Physics 2021-07-05 S Chatterjee , S Roy , A Sen , S Chakraborty , S Das , S K Ghosh , S K Prasad , S Raha , S Biswas

We report on the performance of a Micro-Hole & Strip Plate (MHSP) electron multiplier operating in pure Xe, Kr, Ar and Ne at the pressure range of 1 to 6 bar. The maximal gains at 1 bar Xe and Kr are 50000 and 100000, respectively; they…

Instrumentation and Detectors · Physics 2015-06-26 F. D. Amaro , J. F. C. A. Veloso , A. Breskin , R. Chechik , J. M. F. dos Santos

Multiple-GEM detectors are considered to be good candidates for tracking devices in experiments with high hadronic background. We present the results of the triple-GEM detectors beam test in a high intensity pion beam. The detectors had an…

Instrumentation and Detectors · Physics 2007-05-23 A. Bondar , A. Buzulutskov , L. Shekhtman , A. Sokolov , A. Vasiljev

Gas electron multipliers (GEMs) have been overcoated with a high resistivity 10e14 - 10e15 Ohms / square amorphous carbon layer. The coating avoids charging up of the holes and provides a constant gain immediately after switching on…

Instrumentation and Detectors · Physics 2008-11-26 S. Beirle , U. Werthenbach , G. Zech , T. Zeuner

In this paper, the performances of a type of the domestic THGEM (THick Gaseous Electron Multiplier) working in the Ar/CO2 mixtures are reported in details. This kind of single THGEM can provide the gain range from 100 to 1000, which is very…

GEM are widely used as amplification stages in gaseous detectors exposed to high rates. The GEM consists of a polyimide foil which is coated by two thin copper layers. Charges collected into the holes or created during the amplification…

Instrumentation and Detectors · Physics 2020-07-15 Philip Hauer , Karl Flöthner , Dimitri Schaab , Jonathan Ottnad , Viktor Ratza , Markus Ball , Bernhard Ketzer

We present results on THGEM operation at low gas pressures, in the range 0.5-50 Torr. Gaseous gain up to 100000 was recorded at 10 Torr of Isobutane in a single multiplier element, with pulses rise-time in the few ns range. Cascaded…

Instrumentation and Detectors · Physics 2019-08-15 C. K. Shalem , R. Chechik , A. Breskin , K. Michaeli , N. Ben-Haim

We present the results of our recent studies of a Thick Gaseous Electron Multiplier (THGEM)-based detector, operated in Ar, Xe and Ar:Xe (95:5) at various gas pressures. Avalanche-multiplication properties and energy resolution were…

Instrumentation and Detectors · Physics 2009-11-13 R. Alon , J. Miyamoto , M. Cortesi , A. Breskin , R. Chechik , I. Carne , J. M. Maia , J. M. F. dos Santos , M. Gai , D. McKinsey , V. Dangendorf

The High Energy Physics group of the University of Texas at Arlington Physics Department has been developing Gas Electron Multiplier (GEM) detectors for use as the sensitive gap detector in digital hadron calorimeters (DHCAL) for the future…

Instrumentation and Detectors · Physics 2011-10-20 J. Yu , E. Baldelomar , K. Park , S. Park , M. Sosebee , N. Tran , A. P. White

With the advancement of the accelerator systems and the requirements of high luminosity particle beams to reach different physics goals, detectors with good position resolution and high rate handling capability have become essential for…

Instrumentation and Detectors · Physics 2021-09-15 S. Chatterjee , A. Sen , S. Das , S. K. Ghosh , S. Biswas

The High Energy Physics group of the University of Texas at Arlington Physics Department has been developing Gas Electron Multiplier (GEM) detectors for use as the sensitive gap detector in digital hadron calorimeters (DHCAL) for the future…

Instrumentation and Detectors · Physics 2011-10-20 J. Yu , E. Baldelomar , K. Park , S. Park , M. Sosebee , N. Tran , A. P. White

A prototype Dual Gain Multilayer Thick Gas Electron Multilyer (DG-M-THGEM) with an active area of 10 cm $\times$ 10 cm was manufactured aiming at the production of a large-volume active-target time projection chamber which can work under…

We study the performance of two-phase avalanche detectors based on Gas Electron Multipliers (GEMs) and operated in an electron-avalanching mode in Ar and Xe. Emission, gain, energy resolution and stability characteristics of the detectors…

Instrumentation and Detectors · Physics 2009-11-11 A. Bondar , A. Buzulutskov , A. Grebenuk , D. Pavlyuchenko , R. Snopkov , Y. Tikhonov