English
Related papers

Related papers: Simulation study of electron drift and gas multipl…

200 papers

The dynamics of an argon plasma in the gap of a thermionic diode is investigated using particle-in-cell (PIC) simulations. The time-averaged diode current, as a function of the relative electrical potential between the electrodes, is…

Plasma Physics · Physics 2021-02-24 R. E. Groenewald , S. Clark , A. Kannan , P. Scherpelz

We report on the first observation of electroluminescence and charge amplification with a Virtual Cathode Chamber (VCC) microstrips plate immersed in liquid xenon. Both were observed in an intense non-uniform electric field in the vicinity…

Instrumentation and Detectors · Physics 2025-10-24 Gonzalo Martínez-Lema , Vitaly Chepel , Amos Breskin

We describe a method for coupling an embedded domain in a magnetohydrodynamic (MHD) simulation with a particle-in-cell (PIC) method. In this two-way coupling we follow the work of Daldorff et al. in which the PIC domain receives its initial…

Computational Physics · Physics 2017-10-25 Kirit Makwana , Rony Keppens , Giovanni Lapenta

A simple first-principles mathematical model is developed to predict the performance of a micro photosynthetic power cell ($\mu$PSC), an electrochemical device which generates electricity by harnessing electrons from photosynthesis in the…

To enhance the spatial resolution of the M\"ONCH 25 \textmu m pitch hybrid pixel detector, deep learning models have been trained using both simulation and measurement data. Challenges arise when comparing simulation-based deep learning…

Gas detector are very light instrument used in high energy physics to measure the particle properties: position and momentum. Through high electric field is possible to use the Gas Electron Multiplier (GEM) technology to detect the charged…

The Silicon Electron Multiplier (SiEM) is a novel sensor concept for minimum ionizing particle (MIP) detection which uses internal gain and fine pitch to achieve excellent temporal and spatial resolution. In contrast to sensors where the…

Instrumentation and Detectors · Physics 2022-09-16 Marius Mæhlum Halvorsen , Victor Coco , Evangelos Leonidas Gkougkousis , Paula Collins , Olivier Girard

'EPECUR' experiment setup is under construction at the beam line 322 of the ITEP proton synchrotron. The experiment requires several large area drift chambers to provide reasonable acceptance and fine pitch proportional chambers for beam…

We describe the first tests with a new proportional gas detector. Its geometry consists in slits opened in a copper metallized kapton foil with 30 micron anode strips suspended in these openings. In this way the multiplication process is…

Instrumentation and Detectors · Physics 2007-05-23 J. Claude Labbe , F. Gomez , T. Nunez , A. Pazos , P. Vazquez

A sealed high gas pressure detector working in pure argon is assembled. It consists of a 5 cm $\times$ 5 cm PCB THGEM (THick Gaseous Electron Multipliers). The detector structure and experimental setup are described. The performances under…

Instrumentation and Detectors · Physics 2016-12-26 Yu-Ning Zhang , Qian Liu , Hong-Bang Liu , Yi-Gang Xie , Xiao-Rui Lyu , Shi Chen , Wen-Qian Huang , Dao-Jin Hong , Yang-Heng Zheng

Time Projection Chamber (TPC) has been chosen as the main tracking system in several high-flux and high repetition rate experiments. These include on-going experiments such as ALICE and future experiments such as PANDA at FAIR and ILC.…

Instrumentation and Detectors · Physics 2017-10-03 Purba Bhattacharya , Bedangadas Mohanty , Supratik Mukhopadhyay , Nayana Majumdar , Hugo Natal da Luz

We present the formulation, algorithm and numerical tests of the magnetohydrodynamic-particle-in-cell (MHD-PIC) method with particles treated under the guiding center approximation, which we term the MHD-gPIC method, and it is implemented…

High Energy Astrophysical Phenomena · Physics 2025-10-20 Zitao Hu , Xue-Ning Bai , Xiaochen Sun

A possible implementation of the Micro Drift Chamber (MDC) technique as a high resolution vertex detector in the upstream part of the DIRAC spectrometer was investigated in this paper. Simulations of different MDC layout were performed with…

Instrumentation and Detectors · Physics 2008-05-16 A. Dudarev , V. Kruglov , L. Kruglova , M. Nikitin

The three-dimensional evolution of a pure electron plasma is studied by means of a particle-in-cell code which solves the drift-Poisson system where kinetic effects in the motion parallel to the magnetic field are taken into account.…

Plasma Physics · Physics 2007-05-23 Massimiliano Rome , Roberto Pozzoli , Mauro Pravettoni , Yuri Tsidulko

Gaseous detectors are used in high energy physics as trackers or, more generally, as devices for the measurement of the particle position. For this reason, they must provide high spatial resolution and they have to be able to operate in…

In recent years, constant applied potential molecular dynamics has allowed to study the structure and dynamics of the electrochemical double-layer of a large variety of nanoscale capacitors. Nevertheless it remained impossible to simulate…

Materials Science · Physics 2021-09-03 Thomas Dufils , Michiel Sprik , Mathieu Salanne

A thick gas electron multiplier (THGEM) chamber with an effective readout area of 10$\times$10 cm$^{2}$ and a 11.3 mm ionization gap has been tested along with two regular gas electron multiplier (GEM) chambers in a cosmic ray test system.…

Instrumentation and Detectors · Physics 2015-03-23 S. Yang , S. Das , B. Buck , C. Li , T. Ljubicic , R. Majka , M. Shao , N. Smirnov , G. Visser , Z. Xu , Y. Zhou

Gated wires are widely used in Time Projection Chamber (TPC) to avoid ion back-flow (IBF) in the drift volume. The anode wires can provide stable gain at high voltage with a long lifetime. However, switching on and off the gated grid (GG)…

Instrumentation and Detectors · Physics 2019-07-24 Shuai Wang , Fuwang Shen , Xiao Zhao , Zhihang Zhu , Fangang Kong , Changyu Li , Qinghua Xu , Zhangbu Xu , Chi Yang , Chengguang Zhu

A simple X-ray imaging system using off-the-shelf electronics and simple reconstruction algorithms aiming a spatial resolution of 1.7 mm ($\sim 3\,\%$ of the detector length) is described in this work. For this, two 100 cm$^2$ Gas Electron…

Instrumentation and Detectors · Physics 2015-06-18 H. Natal da Luz , J. A. Mir , X. Carvalho , J. M. F. dos Santos

A numerical study of normal glow discharge properties was performed in the case of small electrodes separations (0.05-0.4 cm) and moderate gas pressures (10-46 Torr). A recently observed new experimental effect of a considerable reduction…

Plasma Physics · Physics 2007-05-23 S. A. Starostin , P. J. M. Peters , E. Kindel , A. V. Azarov , S. V. Mitko , K. J. Boller