English
Related papers

Related papers: Development and operation of a pixel segmented liq…

200 papers

We report on a novel electro-optic device for the diagnostics of high repetition rate laser systems. It is composed of a microwave receiver and of a second order nonlinear crystal, whose irradiation with a train of short laser pulses…

Optics · Physics 2014-03-05 C. Braggio , A. F. Borghesani

We present a smart pixel prototype readout integrated circuit (ROIC) designed in CMOS 28 nm bulk process, with in-pixel implementation of an artificial intelligence (AI) / machine learning (ML) based data filtering algorithm designed as…

A MHz frame rate X-ray area detector (LPD - Large Pixel Detector) is under development by the Rutherford Appleton Laboratory for the European XFEL. The detector will have 1 million pixels and allows analogue storage of 512 images taken at…

Within the ATTRACT FASTPIX project, a monolithic pixel sensor demonstrator chip has been developed in a modified 180 nm CMOS imaging process technology, targeting sub-nanosecond timing precision for single ionising particles. It features a…

Pixelated plastic scintillator arrays can serve as high efficiency and high resolution neutron imaging detectors. Manufacturing these arrays is intensive in both time and labor. This work presents a fabrication method based on additive…

Instrumentation and Detectors · Physics 2026-04-28 Chandler Moore , Juan Manfredi , Michael Febbraro , Daniel Rutstrom , Andrew Decker , Ryan Kemnitz , Thomas Ruland , Paul Hausladen

Monolithic active pixel sensors with depleted substrates present a promising option for pixel detectors in high-radiation environments. High-resistivity silicon substrates and high bias voltage capabilities in commercial CMOS technologies…

During the scheduled high luminosity upgrade of LHC, the world's largest particle physics accelerator at CERN, the position sensitive silicon detectors installed in the vertex and tracking part of the CMS experiment will face more intense…

Instrumentation and Detectors · Physics 2015-01-21 T. Peltola

The Pixel Detector (PXD) of the Belle II experiment at superKEKB accelerator in Japan is based in the DEPFET technology. Two layers of 8+12 modules at a radius of 13 and 22 mm will give a spatial resolution below 10 mm. The radiation level…

Instrumentation and Detectors · Physics 2011-11-21 Pablo Vázquez Regueiro , Eliseo Pérez Trigo , Pablo Rodríguez Pérez

The construction of low mass vertex detectors with a high level of system integration is of great interest for next generation collider experiments. Radiation length images with a sufficient spatial resolution can be used to measure and…

Instrumentation and Detectors · Physics 2016-09-09 U. Stolzenberg , A. Frey , B. Schwenker , P. Wieduwilt , C. Marinas , F. Lütticke

Purpose: In this study, procedures were developed to achieve efficient reversible conversion of a clinical linear accelerator (LINAC) and deliver electron FLASH (eFLASH) or conventional beams to the treatment room isocenter. Material &…

We report on the systematic study of a single-gas-electron-multiplication (GEM) loaded gaseous detector developed for precision measurements of high-energy particle beams and dose-verification measurements. In the present study, a…

Instrumentation and Detectors · Physics 2014-07-29 Kyong Sei Lee , Byungsik Hong , Sang Yeol Kim , Sung Keun Park

The WFC3\IR channel has an innate non-linear response to incident photons, which is corrected for in the calwf3 pipeline with the NLINFILE reference file. The 2009 solution is based on an average polynomial correction for each IR quadrant…

Instrumentation and Methods for Astrophysics · Physics 2026-02-13 K. Huynh , V. Bajaj , M. Marinelli , J. Mack , S. Shenoy , N. Grogin

We have been developing monolithic active pixel sensors for X-rays based on the silicon-on-insulator technology. Our device consists of a low-resistivity Si layer for readout CMOS electronics, a high-resistivity Si sensor layer, and a…

Multiwire and microstrip porous detectors have been developed and investigated for DC operation. The multiwire porous detector consists of anode wires, an Al cathode and a gap between them filled with porous CsI. The microstrip porous…

Instrumentation and Detectors · Physics 2007-05-23 M. P. Lorikyan

The design, construction and performance characteristics of a simple axial-field ionization chamber suitable for identifying ions in a radioactive beam are presented. Optimized for use with low-energy radioactive beams (< 5 MeV/A) the…

Instrumentation and Detectors · Physics 2016-10-12 J. Vadas , Varinderjit Singh , G. Visser , A. Alexander , S. Hudan , J. Huston , B. B. Wiggins , A. Chbihi , M. Famiano , M. M. Bischak , R. T. deSouza

We have developed a prototype system for the ILC vertex detector based on DEPFET pixels. The system operates a 128x64 matrix (with ~35x25 square micron large pixels) and uses two dedicated microchips, the SWITCHER II chip for matrix…

Background: In vivo dosimetry is essential for treatment verification in modern radiotherapy, but existing techniques are limited by spatiotemporal resolution and performance on non-uniform anatomy. Scintillation imaging dosimetry shows…

The High Luminosity LHC (HL-LHC) upgrade requires the planned Inner Tracker (ITk) of the ATLAS detector to tolerate extremely high radiation doses. Specifically, the innermost parts of the pixel system will have to withstand radiation…

The CLIC Tracker Detector (CLICTD) is a monolithic pixel sensor featuring pixels of 30um x 37.5um and a small collection diode. The sensor is fabricated in a 180 nm CMOS imaging process, using two different pixel flavours: the first with a…

Instrumentation and Detectors · Physics 2022-12-21 Katharina Dort