English
Related papers

Related papers: A time projection chamber with optical readout for…

200 papers

In the upcoming LHC Run 3, starting in 2021, the upgraded Time Projection Chamber (TPC) of the ALICE experiment will record minimum bias Pb-Pb collisions in a continuous readout mode at an interaction rate up to 50 kHz. This corresponds to…

Instrumentation and Detectors · Physics 2021-02-03 Marten Ole Schmidt

The ICARUS liquid argon time projection chamber (LArTPC) neutrino detector has been taking physics data since 2022 as part of the Short-Baseline Neutrino (SBN) Program. This paper details the equalization of the response to charge in the…

High Energy Physics - Experiment · Physics 2024-08-06 ICARUS collaboration , P. Abratenko , N. Abrego-Martinez , A. Aduszkiewic , F. Akbar , L. Aliaga Soplin , M. Artero Pons , J. Asaadi , W. F. Badgett , B. Baibussinov , B. Behera , V. Bellini , R. Benocci , J. Berger , S. Berkman , S. Bertolucci , M. Betancourt , M. Bonesini , T. Boone , B. Bottino , A. Braggiotti , D. Brailsford , S. J. Brice , V. Brio , C. Brizzolari , H. S. Budd , A. Campani , A. Campos , D. Carber , M. Carneiro , I. Caro Terrazas , H. Carranza , F. Castillo Fernandez , A. Castro , S. Centro , G. Cerati , A. Chatterjee , D. Cherdack , S. Cherubini , N. Chitirasreemadam , M. Cicerchia , T. E. Coan , A. Cocco , M. R. Convery , L. Cooper-Troendle , S. Copello , A. A. Dange , A. de Roeck , S. Di Domizio , L. Di Noto , C. Di Stefano , D. Di Ferdinando , M. Diwan , S. Dolan , L. Domine , S. Donati , F. Drielsma , J. Dyer , S. Dytman , A. Falcone , C. Farnese , A. Fava , A. Ferrari , N. Gallice , F. G. Garcia , C. Gatto , D. Gibin , A. Gioiosa , W. Gu , A. Guglielmi , G. Gurung , H. Hausner , A. Heggestuen , B. Howard , R. Howell , I. Ingratta , C. James , W. Jang , Y. -J. Jwa , L. Kashur , W. Ketchum , J. S. Kim , D. -H. Koh , J. Larkin , Y. Li , C. Mariani , C. M. Marshall , S. Martynenko , N. Mauri , K. S. McFarland , D. P. Méndez , A. Menegolli , G. Meng , O. G. Miranda , A. Mogan , N. Moggi , E. Montagna , C. Montanari , A. Montanari , M. Mooney , G. Moreno-Granados , J. Mueller , M. Murphy , D. Naples , V. C. L. Nguyen , S. Palestini , M. Pallavicini , V. Paolone , R. Papaleo , L. Pasqualini , L. Patrizii , L. Paudel , G. Petrillo , C. Petta , V. Pia , F. Pietropaolo , F. Poppi , M. Pozzato , G. Putnam , X. Qian , A. Rappoldi , G. L. Raselli , S. Repetto , F. Resnati , A. M. Ricci , G. Riccobene , E. Richards , M. Rosenberg , M. Rossella , P. Roy , C. Rubbia , M. Saad , S. Saha , P. Sala , S. Samanta , P. Sapienza , A. Scaramelli , A. Scarpelli , D. Schmitz , A. Schukraft , D. Senadheera , S-H. Seo , F. Sergiampietri , G. Sirri , J. S. Smedley , J. Smith , L. Stanco , J. Stewart , H. A. Tanaka , F. Tapia , M. Tenti , K. Terao , F. Terranova , V. Togo , D. Torretta , M. Torti , F. Tortorici , R. Triozzi , Y. -T. Tsai , S. Tufanli , T. Usher , F. Varanini , S. Ventura , M. Vicenzi , C. Vignoli , B. Viren , Z. Williams , R. J. Wilson , P. Wilson , J. Wolfs , T. Wongjirad , A. Wood , E. Worcester , M. Wospakrik , H. Yu , J. Yu , A. Zani , J. Zennamo , J. Zettlemoyer , C. Zhang , S. Zucchelli

Exploring new target schemes for laser wakefield accelerators is essential to meet the challenge of increasing repetition rates while ensuring stability and quality of the produced electron beams. The prototyping of a two-chamber gas cell…

We demonstrate a spatial-imaging thermometry technique for ions in a one-dimensional Coulomb crystal by relating their imaged spatial extent along the linear radiofrequency ion trap axis to normal modes of vibration of coupled oscillators…

Atomic Physics · Physics 2016-02-11 V. Rajagopal , J. P. Marler , M. G. Kokish , B. C. Odom

Time of flight of a minimum ionizing particle along a fixed base has been measured with a 100 ps accuracy by means of a Dielectric Resistive Plate Chamber (DRPC) with 4 x 0.3 mm gas gaps. DRPC timing characteristics have been studied with…

Instrumentation and Detectors · Physics 2007-05-23 A. Akindinov , V. Golovin , A. Martemiyanov , V. Petrov , V. Plotnikov , A. Smirnitsky , K. Voloshin

We describe the construction and calibration of a multi-channel liquid time projection chamber filled with Tetramethylsilane (TMS). Its charge readout system consists of 8 wires each in the $X$ and $Y$ directions. The chamber is also…

Instrumentation and Detectors · Physics 2020-06-03 Shuoxing Wu , Brian Lenardo , Manuel Weber , Giorgio Gratta

High-performance event reconstruction is critical for current and future massive liquid argon time projection chambers (LArTPCs) to realize their full scientific potential. LArTPCs with readout using wire planes provide a limited number of…

Instrumentation and Detectors · Physics 2018-05-31 Xin Qian , Chao Zhang , Brett Viren , Milind Diwan

A new Radial Time Projection Chamber (RTPC) was developed at the Jefferson Laboratory to track low-energy nuclear recoils for the purpose of measuring exclusive nuclear reactions, such as coherent Deeply Virtual Compton Scattering and…

Liquid Argon Time Projection Chambers (LArTPCs) are widely used in particle physics experiments. They use light and charge released in events to reconstruct and analyze them. Light information collected by the Photon Detection System (PDS)…

Instrumentation and Detectors · Physics 2025-03-31 Marcio R. Adames

The single-phase liquid argon time projection chamber (LArTPC) provides a large amount of detailed information in the form of fine-grained drifted ionization charge from particle traces. To fully utilize this information, the deposited…

Instrumentation and Detectors · Physics 2023-02-17 MicroBooNE collaboration , C. Adams , R. An , J. Anthony , J. Asaadi , M. Auger , S. Balasubramanian , B. Baller , C. Barnes , G. Barr , M. Bass , F. Bay , A. Bhat , K. Bhattacharya , M. Bishai , A. Blake , T. Bolton , L. Camilleri , D. Caratelli , R. Carr , I. Caro Terrazas , R. Castillo Fernandez , F. Cavanna , G. Cerati , H. Chen , Y. Chen , E. Church , D. Cianci , E. Cohen , G. H. Collin , J. M. Conrad , M. Convery , L. Cooper-Troendle , J. I. Crespo-Anadon , M. Del Tutto , D. Devitt , A. Diaz , M. Dolce , S. Dytman , B. Eberly , A. Ereditato , L. Escudero Sanchez , J. Esquivel , J. J. Evans , A. A. Fadeeva , B. T. Fleming , W. Foreman , A. P. Furmanski , D. Garcia-Gamez , G. T. Garvey , V. Genty , D. Goeldi , S. Gollapinni , E. Gramellini , H. Greenlee , R. Grosso , R. Guenette , P. Guzowski , A. Hackenburg , P. Hamilton , O. Hen , V Hewes , C. Hill , J. Ho , G. A. Horton-Smith , A. Hourlier , E. -C. Huang , C. James , J. Jan de Vries , L. Jiang , R. A. Johnson , J. Joshi , H. Jostlein , Y. -J. Jwa , D. Kaleko , G. Karagiorgi , W. Ketchum , B. Kirby , M. Kirby , T. Kobilarcik , I. Kreslo , Y. Li , A. Lister , B. R. Littlejohn , S. Lockwitz , D. Lorca , W. C. Louis , M. Luethi , B. Lundberg , X. Luo , A. Marchionni , S. Marcocci , C. Mariani , J. Marshall , D. A. Martinez Caicedo , A. Mastbaum , V. Meddage , T. Mettler , T. Miceli , G. B. Mills , A. Mogan , J. Moon , M. Mooney , C. D. Moore , J. Mousseau , M. Murphy , R. Murrells , D. Naples , P. Nienaber , J. Nowak , O. Palamara , V. Pandey , V. Paolone , A. Papadopoulou , V. Papavassiliou , S. F. Pate , Z. Pavlovic , E. Piasetzky , D. Porzio , G. Pulliam , X. Qian , J. L. Raaf , V. Radeka , A. Rafique , L. Rochester , M. Ross-Lonergan , C. Rudolf von Rohr , B. Russell , D. W. Schmitz , A. Schukraft , W. Seligman , M. H. Shaevitz , J. Sinclair , A. Smith , E. L. Snider , M. Soderberg , S. Soldner-Rembold , S. R. Soleti , P. Spentzouris , J. Spitz , J. St. John , T. Strauss , K. Sutton , S. Sword-Fehlberg , A. M. Szelc , N. Tagg , W. Tang , K. Terao , M. Thomson , M. Toups , Y. -T. Tsai , S. Tufanli , T. Usher , W. Van De Pontseele , R. G. Van de Water , B. Viren , M. Weber , H. Wei , D. A. Wickremasinghe , K. Wierman , Z. Williams , S. Wolbers , T. Wongjirad , K. Woodruff , T. Yang , G. Yarbrough , L. E. Yates , B. Yu , G. P. Zeller , J. Zennamo , C. Zhang

Gas-based time projection chambers (TPCs) have been shown to be highly sensitive X-ray polarimeters having excellent quantum efficiency while at the same time achieving large modulation factors. To observe polarization of the prompt X-ray…

Instrumentation and Methods for Astrophysics · Physics 2013-08-06 Z. Prieskorn , J. E. Hill , P. E. Kaaret , J. K. Black , K. Jahoda

The difference in the relative biological efficincy (RBE) of ions of same linear energy transfer (LET) but different atomic number (Z) can be attributed to the difference in the radial ionisation distribution. In this contribution we…

Nuclear Experiment · Physics 2011-04-11 G. Laczko , V. Dangendorf , M. Kraemer , D. Schardt , K. Tittelmeier

A Time Projection Chamber (TPC) using micro-pattern gas detectors is planned as the main tracking device for a detector at the next Linear Collider. A novel support structure for Gas Electron Multipliers (GEMs), which minimizes the material…

Instrumentation and Detectors · Physics 2015-06-17 T. Behnke , F. Müller , A. Münnich , K. Zenker

The International Linear Collider (ILC) Time Projection Chamber (TPC) transverse space-point resolution goal is 100 microns for all tracks including stiff 90 degree tracks with the full 2 meter drift. A Micro Pattern Gas Detector (MPGD)…

Instrumentation and Detectors · Physics 2022-04-26 M. Dixit , D. Attie , A. Bellerive , K. Boudjemline , P. Colas , P. Giganon , I. Giomataris , V. Lepeltier , S. Liu , J. -P. Martin , K. Sachs , Y. Shin , S. Turnbull

We report on studies of fast triggering and high-precision tracking using Resistive Plate Chambers (RPCs). Two beam tests were carried out with the 180 GeV muon beam at CERN using RPCs with gas gaps of 1.00 or 1.15 mm and equipped with…

A large volume Time Projection Chamber (TPC) has been proposed as main tracking device at the International Linear Collider (ILC). Gas electron multipliers (GEMs) are studied as potential replacement of the conventional wire based gas…

Instrumentation and Detectors · Physics 2007-05-23 Peter Wienemann

We have developed a dedicated front-end-electronics board for a high-pressure xenon gas time projection chamber for a neutrinoless double-beta decay search. The ionization signal is readout by detecting electroluminescence photons with…

Instrumentation and Detectors · Physics 2020-09-17 K. Z. Nakamura , S. Ban , A. K. Ichikawa , M. Ikeno , K. D. Nakamura , T. Nakaya , S. Obara , S. Tanaka , T. Uchida , M. Yoshida

A new technique for medical imaging, "3{\gamma} imaging", is studied by our group at SUBATECH for few years. A small liquid xenon time projection chamber prototype has been built in order to demonstrate the feasibility of this technique.…

The concept of a hybrid readout of a time projection chamber is presented. It combines a GEM-based amplification and a pad-based anode plane with a pixel chip as readout electronics. This way, a high granularity enabling to identify…

Instrumentation and Detectors · Physics 2018-01-23 Ulrich Einhaus , Jochen Kaminksi , Michele Caselle

Modern time projection chambers are increasingly based on micro pattern gas detector readout systems. In this paper a self-supporting method used to mount Gas Electron Multiplier foils is presented. It is based on light weight ceramic…

Instrumentation and Detectors · Physics 2015-06-12 Ties Behnke , Ralf Diener , Christoph Rosemann , Lea Steder