Related papers: Gas gain on single wire chambers filled with pure …
Based on the simplified approach it is shown and experimentally confirmed that gas gain in wire chambers at very low pressure becomes higher on thicker wires at the same applied high voltage. This is a consequence of the fact that the first…
We present results on THGEM operation at low gas pressures, in the range 0.5-50 Torr. Gaseous gain up to 100000 was recorded at 10 Torr of Isobutane in a single multiplier element, with pulses rise-time in the few ns range. Cascaded…
Plastic gas pipes are widely used in experimental setups for gaseous detectors, due to their flexibility and easiness of use. This report describes the characterization studies realized on the use of plastic gas pipes, particularly in…
Groove chambers with different pitch and gap height have been tested. Gas amplifications of the order of a few times 10$^{3}$ have been obtained. Combining a groove structure with a GEM pre-amplification foil a gas gain of 10$^{5}$ was…
Multi-channel wire gas electron multipliers (MWGEM) with gaps between the electrodes of 1 and 3mm were investigated. The chamber of the MWGEM was filled with pure commercial neon gas at pressure of 0.4 or 1.0 bar and irradiated by…
The gain measurements of several 1 mm-thick, 10$\times$10 cm$^2$ Thick Gaseous Electron Multipliers (ThGEMs), operated in pure argon at 3.3 bar and room temperature are presented. Electrostatic simulations, performed with the COMSOL…
Gaseous detectors with sense wires are still in use today in small experiments as well as modern ones as those at the LHC. This short note is about the construction of a small wire chamber with limited resources, which could be used both as…
The gas electron multiplier produced with the polyimide film 100 um thick. The maximum gas gain obtained with gas mixture Ar/CH4(91/9) was 5000. No decrease of gas gain with rates up to 2\cdot10^4 1/(mm^2 s) was observed. The possibility of…
Prototypes of MICROMEGAS chambers, using bulk technology and analog readout, with 1x1cm2 readout segmentation have been built and tested. Measurements in Ar/iC4H10 (95/5) and Ar/CO2 (80/20) are reported. The dependency of the prototypes gas…
Gated wires are widely used in Time Projection Chamber (TPC) to avoid ion back-flow (IBF) in the drift volume. The anode wires can provide stable gain at high voltage with a long lifetime. However, switching on and off the gated grid (GG)…
The gas gain and energy resolution of single and double THGEM detectors (5{\times}5cm2 effective area) with mini-rims (rim is less than 10{\mu}m) were studied. The maximum gain can reach 5{\times}103 and 2{\times}105 for single and double…
A prototype of a single-gap glass Resistive Plate Chamber (RPC) is constructed by the authors. To find the considerations required for better operation of the detector's gas system, we have simulated the flow of the Ar gas through the…
We investigate the transport properties of two strongly coupled ballistic one-dimensional (1D) wires, defined by a split-gate structure deposited on a GaAs/AlGaAs double quantum well. Matching the widths and electron densities of the two…
Gas Electron Multiplier (GEM) is one of the devices for gas amplification and available as an amplification part of detectors for many experiments. A GEM with a 50 $\mu m$ thick insulator is popular and widely used in many experimental…
Project GRAND is a 100m x 100m air shower array of position sensitive proportional wire chambers (PWCs) located at 41.7 degrees North and 86.2 degrees West at an elevation of 220m above sea level. Its convenient location adjacent to the…
We present a systematic investigation of the gain properties of a gas electron multiplier (GEM) foil in pure dimethyl ether (DME) at low pressures. The GEM is made from copper- clad liquid crystal polymer insulator (LCP-GEM) designed for…
Basic R & D have been carried out with one small straw tube detector prototype with premixed gas of Ar+CO2 in 70:30 and 90:10 ratio. The gain and the energy resolution are measured with Fe55 X-ray source. Effect of temperature and pressure…
A sealed high gas pressure detector working in pure argon is assembled. It consists of a 5 cm $\times$ 5 cm PCB THGEM (THick Gaseous Electron Multipliers). The detector structure and experimental setup are described. The performances under…
Project GRAND is an extensive air shower array of proportional wire chambers. It has 64 stations in a 100m x 100m area; each station has eight planes of proportional wire chambers with a 50 mm steel absorber plate above the bottom two…
We present an original design for large area gaseous detectors based on the MICROMEGAS technology. This technology incorporates an insulating grid, sandwiched between the micro-mesh and the anode-pad plane, which provides an uniform 200…