Related papers: High Magnetic Field Performance of a GEM-TPC
The new beam profile measurement for the Antiproton Decelerator (AD) at CERN is based on a single Gas Electron Multiplier (GEM) with a 2D readout structure. This detector is very light (~0.4% X0), and measures horizontal and vertical…
Gas Electron Multiplier (GEM) detector, one of the advanced members of the Micro Pattern Gas Detector (MPGD) group, is widely used in High Energy Physics (HEP) experiments. The high rate handling capability and spatial resolution make it a…
A novel instrument has been developed to monitor and record the ambient pa- rameters such as temperature, atmospheric pressure and relative humidity. These parameters are very essential for understanding the characteristics such as gain of…
In view of a possible application as a charge-particle track readout for an Active-Target Time Projection Chamber (AT-TPC), the operational properties and performances of a hybrid Micro-Pattern Gaseous Detector (MPGD) were investigated in…
Controlled etching of copper electrodes in Gas Electron Multiplier foils allows a reduction of the material budget by more than a factor of two for a triple-GEM detector. Detectors making use of thinned foils provide performances similar to…
Performance of triple GEM prototypes has been evaluated by means of a muon beam at the H4 line of the SPS test area at CERN. The data from two planar prototypes have been reconstructed and analyzed offline with two clusterization methods:…
We constructed and operated a double phase (liquid-vapour) pure argon Large Electron Multiplier Time Projection Chamber (LAr LEM-TPC) with a sensitive area of 10x10 cm$^2$ and up to 30 cm of drift length. The LEM is a macroscopic hole…
A combination Time Projection Chamber-Cherenkov prototype detector has been developed as part of the Detector R&D Program for a future Electron Ion Collider. The prototype was tested at the Fermilab test beam facility to provide a proof of…
In this paper we describe the performance of a prototype of the High Angle Time Projection Chambers (HA-TPCs) that are being produced for the Near Detector (ND280) upgrade of the T2K experiment. The two HA-TPCs of ND280 will be instrumented…
Triple-GEM detectors for the GE2/1 and ME0 stations of the endcap muon system for the Phase-2 upgrade of the CMS Experiment have been operated in a test beam to measure their efficiency and spatial resolution, together with a high spatial…
Gas Electron Multiplier (GEM) is one of the devices for gas amplification and available as an amplification part of detectors for many experiments. A GEM with a 50 $\mu m$ thick insulator is popular and widely used in many experimental…
We report the performance of a 10 atm Xenon/trimethylamine time projection chamber (TPC) for the detection of X-rays (30 keV) and gamma-rays (0.511-1.275 MeV) in conjunction with the accurate tracking of the associated electrons. When…
Images of resolved 5.9 keV electron tracks produced from $^{55}$Fe X-ray interactions are presented for the first time using an optical readout time projection chamber (TPC). The corresponding energy spectra are also shown, with the FWHM…
MAGIX is a planned experiment that will be implemented at the upcoming accelerator MESA in Mainz. Due to its location in the energy-recovering lane of the accelerator beam-currents up to 1mA with a maximum energy of 105 MeV will be…
Three Gas-Electron-Multiplier tracking detectors with an active area of 10 cm x 10 cm and a two-dimensional, laser-etched orthogonal strip readout have been tested extensively in particle beams at the Meson Test Beam Facility at Fermilab.…
A chamber for direct detection of WIMPs with masses < 10 GeV/c2 and solar axions is developed. The chamber is filled with a gas mixture of H2 +3ppm TMAE (1,5,10 bar), or D2 + 3ppm TMAE. These gas fillings make it possible to suppress an…
We present the results of our recent studies on a Thick Gas Electron Multiplier (THGEM)-based imaging detector prototype. It consists of two 100x100 mm^2 THGEM electrodes in cascade, coupled to a resistive anode. The event location is…
A new radial time projection chamber based on Gas Electron Multiplier amplification layers was developed for the BONuS12 experiment in Hall B at Jefferson Lab. This device represents a significant evolutionary development over similar…
Two cylindrical forward TPC detectors are described which were constructed to extend the phase space coverage of the STAR experiment to the region 2.5 < |\eta| < 4.0. For optimal use of the available space and in order to cope with the high…
Gas electron multipliers (GEMs) with wire (WGEMs) or metal electrodes (MGEMs), which don't use any plastic insulators between the electrodes are created. The absence of plastic insulation between the electrodes of WGEMs excludes unwanted…