Related papers: Time-resolved fast neutron imaging: simulation of …
Ghost imaging is demonstrated using a poly-energetic reactor source of thermal neutrons. The method presented enables position resolution to be incorporated, into a variety of neutron instruments that are not position resolving. In an…
In a previous work we have demonstrated the feasibility of high-frame-rate, fast-neutron radiography of generic air-water two-phase flows in a 1.5 cm thick, rectangular flow channel. The experiments have been carried out at the…
Neutron imaging is one of the key technologies for non-destructive transmission testing. Recent progress in the development of intensive neutron sources allows us to perform energy-resolved neutron imaging with high spatial resolution.…
The speed and fidelity of detector simulations in particle physics pose compelling questions about LHC analysis and future colliders. The sparse high-dimensional data, combined with the required precision, provide a challenging task for…
A neutron time projection chamber can locate the approximate direction of a neutron hot spot with high efficiency and a 4{\pi} field of view. The angular resolution can be significantly improved by adding several plastic scintillation…
The conceptual design and operational principle of a novel high-efficiency, fast neutron imaging detector based on THGEM, intended for future fan-beam transmission tomography applications, is described. We report on a feasibility study…
Photon detection efficiency is a key parameter of PMTs in high-precision neutrino and dark matter experiments, while most of these experiments are focus on quantum efficiency. More and more experiments are trying to know the detection…
A new high-granular compact time-of-flight neutron detector for the identification and energy measurement of neutrons produced in nucleus-nucleus interactions at the BM@N experiment, Dubna, Russia, at energies up to 4 AGeV is under…
We have demonstrated the feasibility of performing high-frame-rate, fast neutron radiography of air-water two-phase flows in a thin channel with rectangular cross section. The experiments have been carried out at the accelerator facility of…
Progress in neutron decay experiments requires better methods for the characterization of electron detectors. I show that for such \b{eta}-decay studies, electron time-of-flight can be used for in-situ calibration of electron detectors.…
We simulated the response of a 4p calorimetric g-detector array to decays of radioactive isotopes on the s-process path. The GEANT 3.21 simulation package was used. The main table contains estimates on the maximum sample size and required…
In non-destructive evaluation with X-rays light elements embedded in dense, heavy (or high-Z) matrices show little contrast and their structural details can hardly be revealed. Neutron radiography, on the other hand, provides a solution for…
This work is the second part of a simulation study investigating the processing of densely packed and moving granular assemblies by positron emission particle tracking (PEPT). Since medical PET scanners commonly used for PEPT are very…
An analysis methodology is developed for the time-of-flight (TOF) signals recorded by two or more collinear neutron detectors located at different distances from a pulsed neutron source. It is based on taking central moments of the TOF…
To study the dependence of the equation of state of high density nuclear matter on the term characterizing the isospin (proton-neutron) asymmetry of nuclear matter, it is necessary to measure azimuthal flow of neutrons as well as azimuthal…
Gas Electron Multiplier (GEM)-based detectors using a layer of 10B as a neutron converter is becoming popular for thermal neutron detection. A common strategy to simulate this kind of detector is based on two frameworks: Geant4 and…
Gamma-ray emission from special nuclear material (SNM) is relatively easy to shield from detection using modest amounts of high-Z material. In contrast, fast-neutrons are much more penetrating and can escape relatively thick high-Z…
We have developed a photon counting detector system for combined neutron and gamma radiography which can determine position, time and intensity of a secondary photon flash created by a high-energy particle or photon within a scintillator…
We have developed a prototype time-resolved neutron imaging detector employing the micro-pixel chamber (muPIC), a micro-pattern gaseous detector, coupled with a field programmable gate array-based data acquisition system for applications in…
The Helium-3 shortage and the growing interest in neutron science constitute a driving factor in developing new neutron detection technologies. In this work, we report the development of a double-GEM detector prototype that uses a…